GALAXY
SUPREME FIREPLACES
5
Figure 3
- Recommended
Figure 2
– Not Recommended
The right combustion control lever is the Burn Rate Selector (see figure 1). The Burn Rate Selector can slide sideways to
achieve different burn rates. When the Burn Rate Selector is positioned to the left, a maximum burn rate is achieved and
when it is positioned to the right, a minimum burn rate is set.
Keeping the Burn Rate Selector to the right will burn the wood slower. Keeping the Burn Rate Selector to the left will
provide a stronger fire and keep the glass of the fireplace cleaner for longer. Adjust the burn trate according to your heating
requiremments and the quality of your wood.
The combustion air control will automatically and gradually close the primary air source with the presence of heat to
maximize the burn time.
WARNING: The combustion air openings should never be obstructed.
2.4
Starting a Fire
Assure that all the safety precautions mentioned in the owner’s manual are being
respected.
1.
Place two logs in the firebox. The logs should sit directly on the hearth. Do not
use a fireplace grate.
2.
Add a firestarter on top of the two logs.
3.
Add two more logs on top of firestarter and first set of logs. A log should be
positioned directly above the firestarter, but with a one to two inch gap (see
figure 3).
4.
Push the left combustion control lever (the Easy-Light) inwards.
5.
Slide the right combustion control lever (the Burn Rate Selector) to the desired
burn rate. Positioning the Burn Rate Selector towards the left is for maximum
burn rate and towards the right is for minimum burn rate.
6.
Light the firestarter.
7.
Once the firestarter is well lit, close the door. Do not leave the door open for more
than 2 minutes.
Caution:
The wood should be placed away from the door to avoid damage to the glass.
WARNINGS:
Over firing the unit may result in overheating and can damage the
fireplace and/or result in fire hazards. The maximum firewood load must not exceed
4 medium sized logs (approximately 30 pounds). Open the door to reload only when
the wood has been reduced to charcoal, otherwise there is a risk of smoke infiltration
into the house.
This fireplace has been designed to burn with the door closed. When the fireplace is being
used, the door should remain closed at all times. Failing to do so is a safety hazard, will
damage the fireplace and void the warranty.
NOTE:
Always place the wood at the center of the firebox. Keep the bottom logs apart in such a way that at least one slot
of the ashtray grate is not obstructed. The Easy-Light air flows through the grate slots.
WARNING: Do not use fire accelerants to rekindle the fire if the first attempt to start the fire failed. Do not open the
door. Simply reactivate the Easy-Light by pushing it inwards.
NOTE:
Sufficient air exchange is necessary for the fireplace to operate properly. Air is required in order to maintain the
combustion of the fireplace. If the house is airtight, the fireplace may not function properly. If the fireplace is deprived of
air, it will be necessary to provide a source of fresh air into the dwelling. This may be done by using an air exchanger unit or
simply by opening a window or a door near the fireplace partially for a few minutes. Make sure that other equipment such
as the kitchen exhaust fans or oil central heating systems do not affect the fireplace functionality. Large return ducts of
central heating systems located in the same room as the fireplace is installed may affect the proper functioning of the
fireplace and may cause smoking.