6.3 F1 Settings
6.3.1 Weighing Parameters
No.
Sign
Range
Default
Description
REG
100
Weight Unit
0~5
1
Weight Unit
0: UserSet; 1: g; 2: kg; 3: t
4: lb[pound]; 5: oz[ounce]
40101
101
Decimal Point
Position
0~3
1
Decimal Point Position
0: 0; 1: 0.0; 2: 0.00; 3: 0.000
40103
102
Scale Capacity
1~999999
10000
Scale Capacity
Max. allowed loading weight of the load
receptor.
Scale Capacity
≤
Total Capacity of Loadcells –
Self-weight of Load Receptor.
40105
103
Scale Division
1~50
1
Scale Division
0: 1; 1: 2; 2: 5; 3: 10; 4: 20; 5: 50
40107
104
#1&3 Zero Value
-20000~
+999999
0
[*]
Weigher #1 Zero Value
Only for query.
40109
0
[*]
Weigher #3 Zero Value
Only for query.
40117
105
#1&3 Span
Coefficient
0.0001~
999.9999
1.0000
[*]
Weigher #1 Span Coefficient
Only for query.
40111
1.0000
[*]
Weigher #3 Span Coefficient
Only for query.
40119
106
#2&4 Zero Value
-20000~
+999999
0
[*]
Weigher #2 Zero Value
Only for query.
40113
0
[*]
Weigher #4 Zero Value
Only for query.
40121
107
#2&4 Span
Coefficient
0.0001~
999.9999
1.0000
[*]
Weigher #2 Span Coefficient
Only for query.
40115
1.0000
[*]
Weigher #4 Span Coefficient
Only for query.
40123