10
3.4 Data Display & Quick Setting
Name
Description
Authorization
Biggest Digits
Real-time Weight [Weight Unit].
[HI]
Weight Upper Limit Alarm.
[OL]
Overload Alarm.
Bigger Digits
Final Feeding Weight.
[
▲]/[HI]
Positive Deviation Alarm.
[
▼]/[LO]
Negative Deviation Alarm.
[Date&Time]
Date&Time.
[RUN]
Auto Running state.
[PAUSE]
Pause state.
[P_SW]
DI switch ‘Dumping Gate Closed in Place’ turned on.
[ZERO]
Weight
≤
Non-load Zero Range.
[STAB]
Weight is stable.
[Feeder]
Feeder is working.
[FED]
Feeding Ended.
[FIN]
Target Batch [Count/Weight] Finished.
[LABEL]/[GAS]/
[SEW]/[CUT]
In the process of ‘Labeling on Bag’ / ‘Filling Gas into Bag’ / Bag-sewing
/ Thread-cutting.
[SPLY]
In the process of ‘Supplying Material into Feeding Hopper’.
[Au-supply DI]
‘Material Auto-supply Permit’ DI truns ON/OFF.
[RECIPE]
‘Working Recipe’ Setting.
All Users
[TARGET]
‘Target Value’ Setting.
[SP1]
SP1 Lead Value for High-speed Feeding.
[SP2]
SP2 Lead Value for Medium-speed Feeding.
[FALL]
SP3 Fall Value for Low-speed Feeding.
‘AUTO FALL’: Fall Value Auto Correction function is open.
‘FREE FALL’: Fall Value Auto Correction function is closed.
[BAT. CNT]
Target Batch Count.
[CYCLES]
Batch Count.
[BAT. WT]
Target Batch Weight.
[TOTAL]
Totalized Weight.
[CPM]
Packing Speed [Cycles/min].
[Packing Mode]
Combination / Multi-hopper.
Combination / Single-hopper.
Respective / Single-hopper.
Refer to Parameter [303] ‘Packing Mode’.