23
6.2 Main Menu
Main Menu
Second Menu
Sign
Function
Sign
Description
F1-SEt
Parameter
Setting
-SCAL-
Scale parameters setting.
-CALP-
Calibration parameter setting.
-SEtP-
Setpoint parameters setting.
-SErP-
Communication parameters setting.
-dISP-
Display and operation interface parameters setting.
-tIEE-
Time parameters setting.
F2-CAL
System
Calibration
-ZEro-
Zero Calibration without loading on the weigher to correct Zero
Value.
-dAtA-
Data Calibration: Input the specification parameter values of loadcell
[Total Capacity and Output Sensitivity] according to the actual
configuration of the weighing system to correct Span Coefficient. If
there is no access to get the specification parameter values for Data
Calibration, then it’s necessary to do Load Calibration.
-LoAd-
Load Calibration: After doing Data Calibration, if there are
conditions for Load Caliration, do Load Caliration with loading
standard weight on the weigher to correct Span Coefficient further for
higher weighing accuracy.
F3-rEC
Record
Query
Record Query.
F4-CLn
Data
Clearing
--CLS-
Clear Screen:
Clear the display value of Axle Count and Total Axle Weight.
Cancel the present axle weighing process.
--CLr-
Clear Records: Clear all of the axle weighing records.
F5-Loc
Key-locker
-oPEn-
Key-unlocking.
-Locc-
Key-locking.
-PASS-
Password Set.
Exfactory Passwords:
Operator Password: 000000.
Administrator Password: 000001.
Содержание BST106-F19