background image

2-12

             X9DRL-7F/X9DRL-EF Motherboard User’s Manual

Memory Support for the X9DRL-7F/X9DRL-EF Motherboard

The X9DRL-7F/X9DRL-EF Motherboard supports up to 256 GB of DDR3 Regis-
tered/Load Reduced ECC or Unbuffered ECC/Non-ECC 1600/1333/1066/800 MHz 
memory modules in eight DIMM slots. For the latest memory updates, please refer 
to our website a at http://www.supermicro.com/products/motherboard.

Processor & Memory Module Population Configuration

For memory to work properly, follow the tables below for memory installation.

Processors and their Corresponding 

Memory Modules

CPU#

Corresponding DIMM Modules

CPU1

P1-

DIMMA1

P1-

DIMMB1

P1-

DIMMC1

P1-

DIMMD1

CPU2

P2-

DIMME1

P2-

DIMMF1

P2-

DIMMG1

P2-

DIMMH1

Processor and Memory Module Population

Number of

CPUs+DIMMs

CPU and Memory Population Configuration Table

(*For memory to work proper, please install DIMMs in pairs)

1 CPU &

2 DIMMs 

CPU1

P1-DIMMA1/P1-DIMMB1

1 CPU &

4 DIMMs 

CPU1

P1-DIMMA1/P1-DIMMB1, P1-DIMMC1/P1-DIMMD1

2 CPUs &

2 DIMMs

CPU1 + CPU2

P1-DIMMA1, P2-DIMME1

2 CPUs &

4 DIMMs 

CPU1 + CPU2

P1-DIMMA1/P1-DIMMB1, P2-DIMME1/P2-DIMMF1

2 CPUs &

6 DIMMs 

CPU1 + CPU2

P1-DIMMA1/P1-DIMMB1/P1-DIMMC1, P2-DIMME1/P2-DIMMF1/P2-DIMMG1

2 CPUs &

8 DIMMs 

CPU1 + CPU2

P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2-

DIMMG1/P2-DIMMH1

Содержание X9DRL-7F

Страница 1: ...USER S MANUAL Revision 1 0 X9DRL 7F X9DRL EF...

Страница 2: ...DAMAGES IN PARTICULAR SUPER MICRO COMPUTER INC SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTAL...

Страница 3: ...ard is ideal for small form factor server platforms Please refer to our website http www supermicro com for CPU and memory support updates Manual Organization Chapter 1 describes the features specific...

Страница 4: ...tallation Warning Important information given to ensure proper system installation or to prevent damage to the components or injury to yourself Note Additional information given to differentiate betwe...

Страница 5: ...Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Su...

Страница 6: ...c Sensitive Devices 2 4 2 3 Processor and Heatsink Installation 2 5 Installing the LGA2011 Processor 2 5 Installing a Passive CPU Heatsink 2 9 Removing the Heatsink 2 10 2 4 Installing and Removing th...

Страница 7: ...t 80 Header 2 30 Overheat LED Fan Fail 2 30 Power SMB I2 C Connector 2 31 IPMB 2 31 T SGPIO 6 SGPIO Headers 2 32 Standby Power Header 2 32 2 8 Jumper Settings 2 33 Explanation of Jumpers 2 33 GLAN Ena...

Страница 8: ...chandise for Service 3 8 Chapter 4 BIOS 4 1 Introduction 4 1 Starting BIOS Setup Utility 4 1 How To Change the Configuration Data 4 1 Starting the Setup Utility 4 2 4 2 Main Setup 4 2 4 3 Advanced Set...

Страница 9: ...o Mainboard Six 6 Serial ATA cables CBL 0044Lx6 for X9DRL EF Eight 8 Serial ATA cables CBL 0044Lx8 for X9DRL 7F One 1 I O Shield MCP 260 00042 0N One 1 Quick Reference Guide MNL 1462 QRG Note 1 For yo...

Страница 10: ...therboard Image Note All graphics shown in this manual were based upon the latest PCB Revision available at the time of publishing of the manual The motherboard you ve received may or may not look exa...

Страница 11: ...JVRM_I2C1 JVRM_I2C2 JPG1 JPS1 JWD1 JLED1 JMLED1 LEDS1 LEDM1 LED1 C LED2 JF1 T SGPIO1 T SGPIO2 6 SGPIO2 I SATA1 I SATA0 L SAS0 Battery JL1 JPS2 JPS3 JOH1 JI2C1 JI2C2 SP1 JUIDB1 USB0 1 X9DRL 7F EF Rev...

Страница 12: ...DIMMD1 P2 DIMME1 P1 DIMMB1 P2 DIMMH1 P2 DIMMG1 P1 DIMMC1 P2 DIMMF1 COM1 JPW4 JTPM1 LAN2 LAN1 JPW1 JPW2 USB4 JPI2C1 JIPMB1 FAN5 FAN2 FAN3 FAN4 FANA JPL1 JPL2 JVRM_I2C1 JVRM_I2C2 JPG1 JPS1 JWD1 JLED1 JM...

Страница 13: ...for an IPMI Card JL1 Chassis Intrusion JOH1 Overheat LED Indicator JPI2 C1 Power Supply SMBbus I2 C Header JPW1 2 12V 8 Pin Power Connectors See Warning on Pg 1 6 JPW4 24 Pin ATX Main Power Connector...

Страница 14: ...herboard T SGPIO1 2 Seria_Link General Purpose I O Headers 1 2 for SATA ports SP1 Internal Speaker Buzzer FP USB 4 Front Panel Type A USB Connector 4 FP USB 0 1 FP Accessible USB Connectors 0 1 BP USB...

Страница 15: ...s motherboard DIMM sizes DIMM 1GB 2GB 4GB 8GB 16GB and 32GB 1 35V 1 5V Virtualization VT x VT d and VT c Chipset Intel PCH C602J Expansion Two 2 PCI Express 3 0 x8 slots CPU1 Slot4 Slot6 One 1 PCI Exp...

Страница 16: ...for AC power recovery Intel Intelligent Power Node Manager Available when the NMView Utility is installed and special power supply used See the note on Page 1 14 Management Engine PC Health PC Health...

Страница 17: ...Maximum Thermal Design Power TDP is subject to chassis and heatsink cooling restrictions For proper thermal management please check the chassis and heatsink specifications for proper CPU TDP sizing N...

Страница 18: ...CIE 2 0 x1 SATA GEN 3 LPC SPI USB USB PCI 32 33 P0 P1 B E5 2600 DDR3 DIMM DDR3 DIMM E1 F E Socket 01 F1 DDR3 DIMM DDR3 DIMM H1 G G1 CPU1 P1 P0 QPI QPI H PCI E 3 0 x8 PCI E 3 0 x8 SAS2 8 SAS2 7 SAS2 6...

Страница 19: ...with a transfer speed of up to 8 0 GT s providing superb system performance The PCH chipset provides extensive IO support including the following functions and capabilities PCI Express Rev 2 0 support...

Страница 20: ...e user can adjust the voltage thresholds to define the sensitivity of the voltage monitor Fan Status Monitor with Firmware Control The PC health monitoring chip can check the RPM status of a cooling f...

Страница 21: ...tems Slow Blinking LED for Suspend State Indicator When the CPU goes into a suspend state the chassis power LED will start blinking to indicate that the CPU is in suspend mode When the user presses an...

Страница 22: ...agement Controller your system must also have IPNM compatible Manage ment Engine ME firmware installed to use this feature Note Support for IPNM Specification Version 1 5 or Vision 2 0 depends on the...

Страница 23: ...tputs SPI Flash Host BIOS and firmware bootstrap program supported Reduced Media Independent Interface RMII OS Operating System Independency Provides remote Hardware Health Monitoring via IPMI Key fea...

Страница 24: ...1 16 X9DRL 7F X9DRL EF Motherboard User s Manual Notes...

Страница 25: ...omponents Read this section in its entirety before installing or configuring components in the Supermicro chassis Battery Handling Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefah...

Страница 26: ...de explosi n si la bater a se reemplaza de manera incorrecta Re emplazar la bater a exclusivamente con el mismo tipo o el equivalente recomen dado por el fabricante Desechar las bater as gastadas seg...

Страница 27: ...dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y regla mentos nacionales Attention L...

Страница 28: ...do not touch its components periph eral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the motherboard and peripherals back into their antistatic b...

Страница 29: ...at you use an Intel certified multi directional heatsink only Make sure to install the motherboard into the chassis before you install the CPU heatsink When receiving a motherboard without a processor...

Страница 30: ...o release the load plate that covers the CPU socket from its locking position 3 With the lever labelled Close 1st fully retracted gently push down on the lever labelled Open 1st to open the load plate...

Страница 31: ...not drop the CPU on the socket Do not move the CPU horizontally or vertically Do not rub the CPU against the surface or against any pins of the socket to avoid damaging the CPU or the socket Socket K...

Страница 32: ...e load plate with the CPU inside the socket Lock the lever labelled Close 1st first then lock the lever labelled Open 1st second Using your thumb gently push the load levers down to the lever locks OP...

Страница 33: ...already been applied 2 Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the Motherboard and the Heatsink Bracket underneath 3 Screw in two diagonal screws...

Страница 34: ...ws from the motherboard in the sequence as shown in the illustration below 2 Gently wriggle the heatsink to loosen it from the CPU Do not use excessive force when wriggling the heatsink 3 Once the CPU...

Страница 35: ...e release tabs outwards on both ends of the DIMM slot to unlock it Removing Memory Modules Press both notches on the ends of the DIMM module to unlock it Once the DIMM module is loosened remove it fro...

Страница 36: ...s and their Corresponding Memory Modules CPU Corresponding DIMM Modules CPU1 P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 CPU2 P2 DIMME1 P2 DIMMF1 P2 DIMMG1 P2 DIMMH1 Processor and Memory Module Population...

Страница 37: ...e refer to the SMC Recommended Memory List posted on our website at http www supermicro com support resources mem cfm Populating RDIMM ECC Memory Modules Intel E5 2600 Series Processor RDIMM Memory Su...

Страница 38: ...rt and updates please refer to the SMC Recommended Memory List posted on our website at http www supermicro com support resources mem cfm Other Notes and Restrictions For the memory modules to work pr...

Страница 39: ...click in or are screwed in tightly Then use a screwdriver to secure the motherboard onto the motherboard tray Tools Needed Phillips Screwdriver Pan head screws 8 pieces Standoffs 8 pieces if needed Lo...

Страница 40: ...in the chassis as needed 5 Install the motherboard into the chassis carefully to avoid damaging mother board components 6 Using the Phillips screwdriver insert a Pan head 6 screw into a mounting hole...

Страница 41: ...cture below for the colors and locations of the various I O ports Back Panel Connectors and I O Ports Back Panel I O Port Locations and Definitions 1 COM Port 1 Turquoise 2 Back Panel USB Port 6 3 Bac...

Страница 42: ...3 VGA Serial Ports Two COM connections COM1 COM2 are located on the mother board COM1 is located on the Back plane I O panel COM2 located close to TPM Port 80 connector JTPM1 provides front access su...

Страница 43: ...motherboard to provide front USB support In addition four USB ports USB6 7 8 9 are also located on the backplane to provide rear USB support Cables are not included See the tables on the right for pin...

Страница 44: ...9 ports on the backplane to provide KVM support for IPMI 2 0 All these ports accept RJ45 type cables Please refer to the LED Indica tor Section for LAN LED information 1 2 3 X9DRL 7F EF Rev 1 01 LAN...

Страница 45: ...e Front Panel UID LED header is located at Pins 7 8 of the Front Control Panel at JF1 Connect a cable to Pin 8 on JF1 for Front Panel UID LED connec tion When you press the UID button both Rear UID LE...

Страница 46: ...ttons and LED indicators Refer to the following section for descriptions and pin definitions JF1 Header Pins JCOM2 JSD1 P1 DIMMD1 P2 DIMME1 P1 DIMMB1 P2 DIMMH1 P2 DIMMG1 P1 DIMMC1 P2 DIMMF1 COM1 JPW4...

Страница 47: ...LED Pin Definitions JF1 Pin Definition 15 3 3V 16 PWR LED Front Control Panel Pin Definitions A NMI B PWR LED A B JCOM2 JSD1 P1 DIMMD1 P2 DIMME1 P1 DIMMB1 P2 DIMMH1 P2 DIMMG1 P1 DIMMC1 P2 DIMMF1 COM1...

Страница 48: ...on the right for pin definitions HDD LED Pin Definitions JF1 Pin Definition 13 3 3V Standby 14 HD Active C A HDD LED B NIC1 LED C NIC2 LED A GLAN1 2 LED Pin Definitions JF1 Pin Definition 9 Vcc 10 NIC...

Страница 49: ...e Red LED takes precedence over the Blue LED by default Refer to the table on the right for pin definitions OH Fan Fail PWR Fail Blue_UID LED Pin Definitions JF1 Pin Definition 7 Red_LED Cathode OH Fa...

Страница 50: ...R Button A B Power Button Blue OH Fan Fail PWR FaiL UID LED 1 NIC1 Link LED Reset Button 2 Power Fail LED HDD LED FP PWRLED Reset PWR 3 3 V ID_UID_SW 3 3V Stby Red Blue LED Cathode Ground Ground 19 20...

Страница 51: ...therboard be sure to connect the 24 pin ATX PWR JPW4 and the two 8 pin PWR connectors JPW1 JPW2 to the power supply Failure to do so may void the manufacturer warranty on your power supply and motherb...

Страница 52: ...L SAS6 L SAS5 L SAS4 JPME1 JBR1 BIOS JSTBY1 L SAS1 L SAS2 L SAS3 JPME2 FAN1 Chassis Intrusion A Chassis Intrusion header is located at JL1 on the motherboard Attach an appropriate cable from the chas...

Страница 53: ...SATA4 P1 DIMMA1 FPCTRL Intel PCH LSI 2208 CTRL BMC JBT1 LAN CTRL LAN CTRL L SAS7 I SATA5 L SAS6 L SAS5 L SAS4 JPME1 JBR1 BIOS JSTBY1 L SAS1 L SAS2 L SAS3 JPME2 FAN1 B A A Internal Speaker Buzzer B SA...

Страница 54: ...BIOS JSTBY1 L SAS1 L SAS2 L SAS3 JPME2 FAN1 A B A TPM Port 80 Header B JOH1 TPM Port 80 Header A Trusted Platform Module Port 80 header is located at JTPM1 to provide TPM support and Port 80 connecti...

Страница 55: ...X1 CPU1 SLOT4 PCI E 3 0 X8 I SATA2 I SATA3 I SATA4 P1 DIMMA1 FPCTRL Intel PCH LSI 2208 CTRL BMC JBT1 LAN CTRL LAN CTRL L SAS7 I SATA5 L SAS6 L SAS5 L SAS4 JPME1 JBR1 BIOS JSTBY1 L SAS1 L SAS2 L SAS3...

Страница 56: ...A5 L SAS6 L SAS5 L SAS4 JPME1 JBR1 BIOS JSTBY1 L SAS1 L SAS2 L SAS3 JPME2 FAN1 A B A T SGPIO1 B T SGPIO2 C 6 SGPIO0 X9DRL 7F D 6 SGPIO1 X9DRL 7F T SGPIO 6 SGPIO Headers Four SGPIO Serial Link General...

Страница 57: ...L SAS5 L SAS4 JPME1 JBR1 BIOS JSTBY1 L SAS1 L SAS2 L SAS3 JPME2 FAN1 2 8 Jumper Settings Explanation of Jumpers To modify the operation of the mother board jumpers can be used to choose between option...

Страница 58: ...consists of contact pads to prevent accidental clearing of CMOS To clear CMOS use a metal object such as a small screwdriver to touch both pads at the same time to short the connection Always remove...

Страница 59: ...SATA3 I SATA4 P1 DIMMA1 FPCTRL Intel PCH LSI 2208 CTRL BMC JBT1 LAN CTRL LAN CTRL L SAS7 I SATA5 L SAS6 L SAS5 L SAS4 JPME1 JBR1 BIOS JSTBY1 L SAS1 L SAS2 L SAS3 JPME2 FAN1 A VGA Enabled B BMC Enabled...

Страница 60: ...208 CTRL BMC JBT1 LAN CTRL LAN CTRL L SAS7 I SATA5 L SAS6 L SAS5 L SAS4 JPME1 JBR1 BIOS JSTBY1 L SAS1 L SAS2 L SAS3 JPME2 FAN1 I2 C Bus to PCI Exp Slots Use Jumpers JI2 C1 and JI2 C2 to connect the Sy...

Страница 61: ...State Definition Link Left Green Solid 100 Mbps Activity Right Amber Blinking Active GLAN LEDs There are two GLAN ports on the moth erboard Each Gigabit Ethernet LAN port has two LEDs The Yellow LED...

Страница 62: ...I SATA3 I SATA4 P1 DIMMA1 FPCTRL Intel PCH LSI 2208 CTRL BMC JBT1 LAN CTRL LAN CTRL L SAS7 I SATA5 L SAS6 L SAS5 L SAS4 JPME1 JBR1 BIOS JSTBY1 L SAS1 L SAS2 L SAS3 JPME2 FAN1 B Onboard Power LED An On...

Страница 63: ...E 3 0 X8 I SATA2 I SATA3 I SATA4 P1 DIMMA1 FPCTRL Intel PCH LSI 2208 CTRL BMC JBT1 LAN CTRL LAN CTRL L SAS7 I SATA5 L SAS6 L SAS5 L SAS4 JPME1 JBR1 BIOS JSTBY1 L SAS1 L SAS2 L SAS3 JPME2 FAN1 B A A L...

Страница 64: ...OH1 JI2C1 JI2C2 SP1 JUIDB1 USB0 1 X9DRL 7F EF Rev 1 01 PCH SLOT3 PCI E 2 0 X4 IN X8 CPU1 SLOT6 PCI E 3 0 X8 CPU1 VGA USB8 9 USB6 7 IPMI_LAN CPU2 JPB1 6 SGPIO1 PCH SLOT2 PCI E 2 0 X1 CPU1 SLOT4 PCI E 3...

Страница 65: ...I SATA3 E I SATA4 F I SATA5 For X9DRL 7F G L SAS0 H L SAS1 I L SAS2 J L SAS3 K L SAS4 L L SAS5 M L SAS6 N L SAS7 I SATA L SAS Pin Definitions Pin Definition 1 Ground 2 TX_P 3 TX_N 4 Ground 5 RX_N 6 RX...

Страница 66: ...2 42 X9DRL 7F X9DRL EF Motherboard User s Manual Notes...

Страница 67: ...the motherboard and chassis 2 Disconnect all ribbon wire cables from the motherboard including those for the keyboard and mouse 3 Remove all add on cards 4 Install CPU 1 first making sure it is fully...

Страница 68: ...by unplugging the power cord and contracting both pads on the CMOS Clear Jumper JBT1 Refer to Section 2 8 in Chapter 2 2 Remove all components from the motherboard especially the DIMM modules Make su...

Страница 69: ...results 5 Make sure that all memory modules are fully seated in their slots Follow the instructions given in Section 2 4 in Chapter 2 6 Please follow the instructions given in the DIMM Population Tab...

Страница 70: ...hooting Remove all unnecessary components starting with add on cards first and use minimum configuration with a CPU and a memory module installed to identify the trouble areas Refer to the steps liste...

Страница 71: ...upport 2 BIOS upgrades can be downloaded from our website http www supermicro com 3 If you still cannot resolve the problem include the following information when contacting Supermicro for technical s...

Страница 72: ...omply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly 3 3 Battery Removal and Installation Battery Removal To remove the onboard ba...

Страница 73: ...an your BIOS before downloading You can choose from the zip file and the exe file If you choose the zip BIOS file please unzip the BIOS file onto a bootable USB device Run the batch file using the for...

Страница 74: ...e prominently displayed on the outside of the shipping carton and the shipping package is mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be maile...

Страница 75: ...the user The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often a text messa...

Страница 76: ...ttom corner of the screen below the copyright message Warning Do not upgrade the BIOS unless your system has a BIOS related issue Flashing the wrong BIOS can cause irreparable damage to the system In...

Страница 77: ...d in Day MM DD YY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 Supermicro X9DRL 7F Version This item displays the versi...

Страница 78: ...terrupt 19 is the software interrupt that handles disk boot When this item is set to Enabled the ROM BIOS of the host adaptors will capture Interrupt 19 at boot up and allow the drives that are attach...

Страница 79: ...last power state before a power loss The options are Power On Stay Off and Last State CPU Configuration This submenu displays the information of the CPU as detected by the BIOS It also allows the use...

Страница 80: ...PU performance The options are Enabled and Disabled Active Processor Cores Set to Enabled to use a processor s Second Core and beyond Please refer to Intel s web site for more information The options...

Страница 81: ...abled and Enabled DCU IP Prefetcher Select Enabled for DCU Data Cache Unit IP Prefetcher support which will prefetch IP addresses to enhance network connectivity and system performance The options are...

Страница 82: ...system During the CPU C3 State the CPU clock generator is turned off The options are Enabled and Disabled CPU C6 Report Available when Power Technology is set to Custom Select Enabled to allow the BIO...

Страница 83: ...the manufacturer Short Duration Power Limit During Turbo Mode the system may consume more power than the default power setting set for a processor and thus exceeds the Short Duration Power limit By i...

Страница 84: ...iency The default is Enabled and can not be changed MMCFG Base Use this feature to select the default value for the PCI MMIO Memory Mapped IO Base Address The lower the value the less available the sy...

Страница 85: ...rent Memory Mode This item displays the current memory mode Current Memory Speed This item displays the current memory speed Mirroring This item displays if memory mirroring is supported by the mother...

Страница 86: ...detected on a memory module and send the correction to the requestor the original source When this item is set to Enabled the IO hub will read and write back one cache line every 16K cycles if there...

Страница 87: ...USB Devices is set to Enabled Select Enabled to enable EHCI Enhanced Host Controller Interface Controller 1 or Controller 2 to enhance system performance The options are Disabled and Enabled Legacy U...

Страница 88: ...efault for SATA Controller 0 is Compatible The default of SATA Controller 1 is Enhanced AHCI Mode The following items are displayed when the AHCI Mode is selected Aggressive Link Power Management When...

Страница 89: ...tion ROMs available The options are UEFI Only and Legacy Only PCI Latency Timer Use this feature to set the latency timer of each PCI device installed on a PCI bus Select 64 to set the PCI latency to...

Страница 90: ...x4 in x8 OPROM CPU1 Slot 4 PCI E 3 0 x8 OPROM CPU1 Slot 6 PCI E 3 0 x8 OPROM Select Enabled to enable Option ROM support to boot the computer using a device installed on a slot specified above The opt...

Страница 91: ...Port 1 Change Settings This option specifies the base I O port address and the Interrupt Request address of COM Port 1 The options are Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 IO 2F8h IRQ 3 IO 3E8h IRQ 5 IO 2...

Страница 92: ...peed Serial Port Console Redirection These submenus allow the user to configure the following Console Redirection settings for a COM Port 1 or COM Port 2 as specified by the user COM 1 SOL Serial Over...

Страница 93: ...the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data packet Sel...

Страница 94: ...options are Enabled and Disabled Console Redirection Settings This feature allows the user to specify how the host computer will exchange data with the client computer which is the remote computer us...

Страница 95: ...arity bit to be sent along with the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the...

Страница 96: ...on settings ME BIOS Interface Version ME Version Trusted Computing Available if a TPM device is installed Configuration TPM Support Select Enabled on this item and enable the TPM jumper on the motherb...

Страница 97: ...based attacks and ensures protection confidentiality and integrity of data stored or created on the system CPU Chipset TXT Feature Displays status of TXT Feature support TXT Support Indicates if TXT...

Страница 98: ...rt Change this item to enable or disable runtime error logging The options are En abled and Disabled Memory Correction Error Threshold Change this item to define the system s memory correction error t...

Страница 99: ...abled MECI The Multiple Event Count Increment MECI counter counts the number of oc curences a duplicate event must happen before the MECI counter is incremented This is a numeric value ranging from 1...

Страница 100: ...mediately BMC Network Configuration LAN Channel 1 This feature allows the user to configure the settings for LAN Channel 1 IPMI LAN Selection This feature displays the available IPMI LAN modes IPMI Ne...

Страница 101: ...it number separated by dots should not exceed 255 Station MAC Address This item displays the Station Mac address for this computer Mac addresses are 6 two digit hexadecimal numbers Gateway IP Address...

Страница 102: ...of boot priority for a device specified by the user Add New Boot Option This feature allows the user to configure the following settings when adding a new device to the boot priority list Add Boot Opt...

Страница 103: ...tem Password Check This item allows you to decide when the system should check for a password after it has been entered Select Setup for the system to prompt for a password before the user enters the...

Страница 104: ...ve Changes and Reset When you have completed the system configuration changes select this option to save the changes and reboot the computer so that the new system configuration settings can take effe...

Страница 105: ...is feature and press Enter to save the current settings as the user s defaults When the dialog box appears asking you if you want to save values as user s defaults select Yes to save the current value...

Страница 106: ...4 32 X9DRL 7F X9DRL EF Motherboard User s Manual Notes...

Страница 107: ...re usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the cor responding error A 1 BIOS Error Beep Codes X9 Motherboard BI...

Страница 108: ...A 2 X9DRL 7F X9DRL EF Motherboard User s Manual Notes...

Страница 109: ...you may down load individual drivers and utilities After creating a CD DVD with the ISO files insert the disk into the CD DVD drive on your system and the display shown below should appear Note 1 Clic...

Страница 110: ...such as CPU temperature system voltages and fan status See the figures below for examples of the SuperDoctor III interface Note 1 The default User Name and Password for SuperDoctor III is ADMIN ADMIN...

Страница 111: ...splay Screen Remote Control Note The SuperDoctor III program and User s Manual can be downloaded from the Supermicro web site at http www supermicro com products ac cessories software SuperDoctorIII c...

Страница 112: ...B 4 X9DRL 7F X9DRL EF Motherboard User s Manual Notes...

Страница 113: ...expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in su...

Отзывы: