2-26
X9DR7-TF+/X9DRE-TF+ Motherboard User’s Manual
Power Button
Blue+ (OH/Fan Fail/
PWR FaiL/UID LED)
1
NIC1 Link LED
Reset Button
2
Power Fail LED
HDD LED
FP PWRLED
Reset
PWR
3.3 V
ID_UID_SW/3/3V Stby
Red+ (Blue LED Cathode)
Ground
Ground
19
20
3.3V
X
Ground
NMI
X
NIC2 Link LED
NIC2 Activity LED
NIC1 Activity LED
JS
3
LEM1
SW1
JSTBY1
JBR1 JWD1
JPG1
JPB1
JPL1
JPS1
JWP1
JPME
1
JPME
2
LE
2
JBT1
J2
1
JTPM
1
JIPMB1
FA
N6
FAN5
FA
NB
FA
NA
FA
N4
FA
N3
FA
N2
FAN1
JI2C
1
JOH
1
JI2C
2
JP
6
JL1
JBAT1
J1
7
SP1
JSD1
JPW1
JPW2
JPI2C1
JD
1
JF1
X9DR7-TF+
Rev. 1.00
BBU
CPU2 SLOT3 PCI-E 3.0 X1
6
I-S
AT
A4
L-SAS 4~7
CPU1 SLOT4 PCI-E 3.0 X8
CPU1 SLOT1 PCI-E 3.0 X8
XDP-CPU
CPU1 SLOT2 PCI-E 3.0 X8
USB9
I-SATA3
I-S
AT
A1
COM2
USB6/7
USB4/5
I-S
AT
A2
I-S
AT
A0
CPU2 SLOT6 PCI-E 3.0 X8
CPU2 SLOT5 PCI-E 3.0 X1
6
I-S
AT
A5
L-SAS 0~3
UID
VGA
LAN2
P1 DIMMC
1
P1 DIMMC
2
P1 DIMMC
3
P1 DIMMD
1
P1 DIMMD
2
P1 DIMMD
3
LAN1
P1 DIMMB
3
P1 DIMMB
2
P1 DIMMB
1
P2 DIMME
1
P2 DIMME2
P1 DIMMA
3
P1 DIMMA
2
P2 DIMME3
P2 DIMMF
1
P1 DIMMA
1
P2 DIMMF3
P2 DIMMF
2
P2 DIMMH
3
P2 DIMMH
2
P2 DIMMH
1
P2 DIMMG
3
P2 DIMMG1
P2 DIMMG
2
USB2&3
USB0&1
IPMI_LAN
KB/Mouse
COM1
JPW3
LE1
JP
7
J1
8
DS1
DS3
DS2
LEDS
1
LEDS
2
CPU2
CPU1
Battery
BMC
CTRL
CTRL
LAN
PCH
CTRL
SAS
JRK1
Power Fail LED
The Power Fail LED connection is
located on pins 5 and 6 of JF1. Re-
fer to the table on the right for pin
definitions.
A. OH/Fail/PWR Fail LED
B. PWR Supply Fail
PWR Fail LED
Pin Definitions (JF1)
Pin# Definition
5
3.3V
6
PWR Supply Fail
B
A
Overheat (OH)/Fan Fail/PWR Fail/
UID LED
Connect an LED cable to pins 7 and
8 of Front Control Panel to use the
Overheat/Fan Fail/Power Fail and
UID LED connections. The Red LED
on pin 7 provides warnings of over-
heat, fan failure or power failure. The
Blue LED on pin 8 works as the front
panel UID LED indicator. The Red
LED takes precedence over the Blue
LED by default. Refer to the table on
the right for pin definitions.
OH/Fan Fail/ PWR Fail/Blue_UID
LED Pin Definitions (JF1)
Pin# Definition
7
Red_LED-Cathode/OH/Fan Fail/
Power Fail5.5V.SB
8
Blue_UID LED
OH/Fan Fail/PWR Fail
LED Status (Red LED)
State Definition
Off
Normal
On
Overheat
Flashing
Fan Fail
Содержание X9DR7-TF+
Страница 1: ...USER S MANUAL Revision 1 1 X9DR7 TF X9DRE TF...
Страница 68: ...2 44 X9DR7 TF X9DRE TF Motherboard User s Manual Notes...
Страница 110: ...4 34 X9DR7 TF X9DRE TF Motherboard User s Manual Notes...
Страница 112: ...A 2 X9DR7 TF X9DRE TF Motherboard User s Manual Notes...
Страница 116: ...B 4 X9DR7 TF X9DRE TF Motherboard User s Manual Notes...