Chapter 4: AMI BIOS
4-9
Hysteresis Temperature (Closed Loop Only)
Temperature Hysteresis is the temperature lag (in degrees Celsius) after the
set DIMM temperature threshold is reached before Closed Loop Throttling
begins. The options are Disabled,
1.5oC
, 3.0
o
C, and 6.0
o
C.
Guardband Temperature (Closed Loop Only)
Use this feature to change the DIMM temperature threshold. Each step is
in 0.5
o
C increment. The default is
[006]
.
Inlet Temperature
This is the temperature detected at the chassis inlet. Each step is in 0.5
o
C
increment. The default is
[070]
. Press "+" or "-" on your keyboard to change
this value.
Temperature Rise
This is the temperature rise to the DIMM thermal zone. Each step is in
0.5
o
C increment. The default is
[020]
. Press "+" or "-" on your keyboard to
change this value.
Air Flow
This is the air fl ow speed to the DIMM modules. Each step is one mm/
sec. The default is
[1500]
. Press "+" or "-" on your keyboard to change
this value.
Altitude
This feature defi nes how many meters above or below sea level the system
is located. The options are
Sea Level or Below,
1~300, 301~600, 601~900,
901~1200, 1201~1500, 1501~1800, 1801~2100, 2101~2400, 2401~2700,
2701~3000.
DIMM Pitch
This is the physical space between each DIMM module. Each step is in
1/1000 of an inch. The default is
[400]
. Press "+" or "-" on your keyboard
to change this value.
Serial Debug Message Level
This feature allows the user to set the level of debug message to be displayed.
The default setting is
None
.
Margin Ranks
This feature allows the user to set the margin for each rank after confi guring
Rx DQ, TX DQ, Rx Vref, and Tx Vref settings. The options are Enabled, and
Disabled
.
Содержание X8DTG-DF
Страница 1: ...X8DTG DF USER S MANUAL Revision 1 0...
Страница 5: ...Contacting Supermicro v Notes...
Страница 52: ...2 32 X8DTG DF User s Manual Notes...
Страница 86: ...4 30 X8DTG DF User s Manual Notes...
Страница 88: ...A 2 X8DTG DF User s Manual Notes...
Страница 94: ...C 4 X8DTG DF User s Manual Notes...