Chapter 4: BIOS
4-21
Console Redirection
Access the submenu to make changes to the following settings:
COM Port Address
This setting will allow you to specify which COM port to direct the remote con-
sole to: Onboard COM A or Onboard COM B. The options are
Disabled,
COM
A and COM B
.
Baud Rate
This setting will enable you to set the BAUD rate for the console redirection. The
options are 300,1200, 2400, 9600,
19.2 K,
38.4K, 57.6K, and 115.2K.
Console Type
This setting will enable you to set the console redirection type. The options are
VT100, VT100 (8bit), PC ANSI (7bit),
PC ANSI,
VT100+, VT-UTF8 and ASCII.
Flow Control
This setting enables you to select the flow control option for the console. The
options are: None, XON/XOFF, and
CTS/RTS
.
Console Connection
This setting allows you to decide how the console redirection is to be connected.
The options are
Direct
or Via Modem.
Continue CR after Post
This setting allows you to decide if you would like to continue with the console
redirection after the POST routine. The options are On and
Off
.
Hardware Monitoring
This feature allows the BIOS to automatically monitor the following components
and display the temperature of each component as detected. Highlight this and hit
<Enter> to see monitor data for the following items: