2-22
X10SLV/-Q Motherboard User's Manual
Overheat (OH)/Fan Fail LED
Connect an LED Cable to the OH/Fan
Fail connection on pins 7 and 8 of JF1
to provide advanced warnings of chassis
overheat or fan failure. Refer to the table
on the right for pin definitions.
OH/Fan Fail Indicator
Status
State Definition
Off
Normal
On
Overheat
Flash
-
ing
Fan Fail
JF1 Header Pins
C
Power Button
The Power Button connection is located
on pins 1 and 2 of JF1. Momentarily
contacting both pins will power on/off the
system. To turn off the power when set
to suspend mode, press the button for
at least 4 seconds. Refer to the table on
the right for pin definitions.
Power Button
Pin Definitions (JF1)
Pin# Definition
1
Signal
2
Ground
Reset Button
The Reset Button connection is located
on pins 3 and 4 of JF1. Attach it to a
hardware reset switch on the computer
case. Refer to the table on the right for
pin definitions.
Reset Button
Pin Definitions (JF1)
Pin# Definition
3
Reset
4
Ground
OH/Fan Fail LED
Reset Button
PWR Button
A
B
A
B
Power Button
OH/Fan Fail LED
1
NIC1 LED
Reset Button
2
HDD LED
Power LED
Reset
PWR
LE
LE
LE
LE
Ground
Ground
X
X
NIC2 LED
LE
C
Содержание X10SLV
Страница 1: ...X10SLV X10SLV Q USER S MANUAL Revision 1 0...
Страница 66: ...3 6 X10SLV Q Motherboard User s Manual Notes...
Страница 98: ...A 2 X10SLV Q Motherboard User s Manual Notes...
Страница 102: ...B 4 X10SLV Q Motherboard User s Manual Notes...