4-32
X10DRH-C/CT/i/iT Motherboard User’s Manual
Azalia
Select Enabled to enable onboard Azalia audio devices. Select Auto for the BOIS to automatically enable Azalia support when an onboard Azalia device is detected. The settings
are
Auto
, Enabled, and Disabled.
Azalia PME Enable
Select Enabled to enable PME (Power Management Event) support for Azalia. The settings are Enabled and
Disabled
.
*If the item above set to Enabled, the following items will become available for
configuration:
COM1 Console Redirection Settings
Terminal Type
Use this item to select the target terminal emulation type for Console Redirec-
tion. Select VT100 to use the ASCII Character set. Select VT100+ to add color
and function key support. Select ANSI to use the Extended ASCII Character set.
Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or
more bytes. The options are
ANSI, VT100,
VT100+
, and VT-UTF8.
Bits Per second
Use this item to set the transmission speed for a serial port used in Console
Redirection. Make sure that the same speed is used in the host computer and the
client computer. A lower transmission speed may be required for long and busy
lines. The options are 9600, 19200, 38400, 57600 and
115200
(bits per second).
Data Bits
Use this item to set the data transmission size for Console Redirection. The
options are 7 (Bits) and
8 (Bits)
.
Parity
A parity bit can be sent along with regular data bits to detect data transmission
errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits
is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits
is odd. Select None if you do not want to send a parity bit with your data bits
in transmission. Select Mark to add a mark as a parity bit to be sent along with
the data bits. Select Space to add a Space as a parity bit to be sent with your
data bits. The options are
None
, Even, Odd, Mark and Space.
Stop Bits
A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard
serial data communication. Select 2 Stop Bits if slower devices are used. The
options are
1
and 2.
Flow Control
Use this item to set the flow control for Console Redirection to prevent data
loss caused by buffer overflow. Send a "Stop" signal to stop sending data when
the receiving buffer is full. Send a "Start" signal to start sending data when the
receiving buffer is empty. The options are
None