Chapter 2: Server Installation
2-5
Installing the Chassis Rails
You will need to remove the top cover and the feet to add rack rails to the chassis.
First, remove the top and right covers (top and left covers when standing as a tower
chassis) by fi rst removing the screws that secure them to the chassis. Depress the
button on the top (side if tower) of the chassis to release the cover and then pull
the cover off. Then unscrew the four feet and remove them from the chassis (see
Figure 2-2).
You can now attach rack rails to the top and bottom (now the sides) of the chassis.
First add the rack handles. Then position the inner chassis rail sections you just
removed along the side of the chassis making sure the screw holes line up. Note
that these two rails are left/right specifi c. Screw the rail securely to the side of the
chassis (see Figure 2-3). Repeat this procedure for the other rail on the other side
of the chassis. You will also need to attach the rail brackets when installing into a
telco rack.
Locking Tabs:
As mentioned, the chassis rails have a locking tab, which serves
two functions. The fi rst is to lock the server into place when installed and pushed
fully into the rack, which is its normal position. Secondly, these tabs also lock the
server in place when fully extended from the rack. This prevents the server from
coming completely out of the rack when you pull it out for servicing.
Figure 2-2. Preparing to Install the Chassis Rails
Содержание SUPERSERVER 7045W-NTR+
Страница 1: ... SUPERSERVER 7045W NTR SUPER USER S MANUAL 1 0 ...
Страница 5: ...v Preface Notes ...
Страница 24: ...2 10 SUPERSERVER 7045W NTR User s Manual Figure 2 5 Accessing the Inside of the System Rack Configuration shown ...
Страница 28: ...3 4 SUPERSERVER 7045W NTR User s Manual Notes ...
Страница 43: ...Chapter 5 Advanced Serverboard Setup 5 11 Figure 5 4 X7DWN Layout not drawn to scale 5 8 Serverboard Details ...
Страница 58: ...5 26 SUPERSERVER 7045W NTR User s Manual Notes ...
Страница 63: ...Chapter 6 Advanced Chassis Setup 6 5 Figure 6 4 Removing the Air Shroud Figure 6 3 Removing a Chassis Fan ...
Страница 102: ...A 6 SUPERSERVER 7045W NTR User s Manual Notes ...
Страница 108: ...B 6 SUPERSERVER 7045W NTR User s Manual Notes ...
Страница 122: ...C 14 SUPERSERVER 7045W NTR User s Manual Notes ...
Страница 146: ...E 4 SUPERSERVER 7045W NTR User s Manual Notes ...