6-5
Chapter 6: Advanced Chassis Setup
Figure 6-3. System Cooling Fan Removal
Replacing System Cooling Fans
Removing a system cooling fan
With the chassis cover removed, first unplug the fan cable corresponding
to the failed fan. Then remove the fan unit from the chassis by depressing
the locking tab on the fan housing and pulling the unit straight up (see
Figure 6-3). Take apart the fan housing to remove the fan from inside.
Installing a new system cooling fan
Replace the failed fan with an identical 9-cm, 12 volt fan (available from
Supermicro). After the new fan has been installed, reassemble the fan
housing and plug it back into its slot. You should hear it click into place
when fully inserted. Then plug the fan cable back into the same header on
the circuit board you removed it from. You should then wind the excess
cable around the tabs on the fan housing to keep it out of the way. Check
that the fan is working properly and that all the LEDs on the control panel
circuit board (Figure 6-2) and the control panel have turned off. Finish by
replacing the top panel of the chassis.
Locking Tab