5-18
S
UPER
S
ERVER 6037R-72RFT User's Manual
Chassis Intrusion
The Chassis Intrusion header is des-
ignated JL1. Attach an appropriate
cable from the chassis to inform you
of a chassis intrusion when the chas-
sis is opened
Chassis Intrusion
Pin Defi nitions
Pin# Defi nition
1
Intrusion Input
2
Ground
Internal Speaker
The Internal Speaker, located at SP1,
can be used to provide audible indica-
tions for various beep codes. See the
table on the right for pin defi nitions.
Internal Buzzer (SP1)
Pin Defi nition
Pin# Defi nitions
Pin 1
Pos. (+)
Beep In
Pin 2
Neg. (-)
Alarm
Speaker
Overheat/Fan Fail LED
The JOH1 header may be connected
to an LED indicator to provide warn-
ings of chassis overheating or fan
failure. Refer to the table on right for
pin defi nitions.
OH/Fan Fail LED
Status
State Message
Solid
Overheat
Blinking
Fan Fail
TPM Header/Port 80 Header
A Trusted Platform Module/Port 80
header is located at JTPM1 to provide
TPM support and Port 80 connection.
Use this header to enhance system
performance and data security. See
the table on the right for pin defi ni-
tions.
TPM/Port 80 Header
Pin Defi nitions
Pin # Defi nition
Pin # Defi nition
1
LCLK
2
GND
3
LFRAME#
4
<(KEY)>
5
LRESET#
6
+5V (X)
7
LAD 3
8
LAD 2
9
+3.3V
10
LAD1
11
LAD0
12
GND
13
SMB_CLK4
14
SMB_DAT4
15
+3V_DUAL
16
SERIRQ
17
GND
18
CLKRUN# (X)
19
LPCPD#
20
LDRQ# (X)
Содержание SuperServer 6037R-72RFT
Страница 1: ...SUPERSERVER 6037R 72RFT SUPER USER S MANUAL 1 0...
Страница 5: ...Notes Preface v...
Страница 14: ...1 6 SUPERSERVER 6037R 72RFT User s Manual Notes...
Страница 24: ...SUPERSERVER 6037R 72RFT User s Manual 3 4 Notes...
Страница 56: ...5 28 SUPERSERVER 6037R 72RFT User s Manual Notes...
Страница 61: ...Chapter 6 Advanced Chassis Setup 6 5 Figure 6 2 Replacing a Rear Fan Figure 6 3 Installing the Air Shroud...
Страница 98: ...A 2 SUPERSERVER 6037R 72RFT User s Manual Notes...