Chapter 2: Server Installation
2-5
Figure 2-2. Installing Chassis Rails
Installing the Chassis Rails
Position the fi xed chassis rail sections you just removed along the side of the
6025B-T/6025B-8 making sure the screw holes line up. Note that these two rails
are left/right specifi c. Screw the rail securely to the side of the chassis (see Figure
2-2). There should be two screws for each side. Repeat this procedure for the other
rail on the other side of the chassis. You will also need to attach the rail brackets
when installng into a telco rack.
Locking Tabs:
As mentioned, both chassis rails have a locking tab, which serves
two functions. The fi rst is to lock the server into place when installed and pushed
fully into the rack, which is its normal position. Secondly, these tabs also lock the
server in place when fully extended from the rack. This prevents the server from
coming completely out of the rack when you pull it out for servicing.