Chapter 7: BIOS
7-11
Slot1 PCI-Exp x8
Access the submenu for each of the settings above to make changes to the
following:
Option ROM Scan
When enabled, this setting will initialize the device expansion ROM. The options
are
Enabled
and Disabled.
Enable Master
This setting allows you to enable the selected device as the PCI bus master.
The options are
Enabled
and Disabled.
Latency Timer
This setting allows you to set the clock rate for Bus Master. A high-priority, high-
throughout device may benefi t from a greater clock rate. The options are
Default
,
0020h, 0040h, 0060h, 0080h, 00A0h, 00C0h, and 00E0h. For Unix, Novell and
other Operating Systems, please select the option: other. If a drive fails after
the installation of a new software, you might want to change this setting and
try again. A different OS requires a different Bus Master clock rate
.
Large Disk Access Mode
This setting determines how large a hard drive is to be accessed. The options are
DOS
or Other (for Unix, Novelle NetWare and other operating systems).
Advanced Chipset Control
Access the submenu to make changes to the following settings.
Warning
: Use caution when changing the Advanced settings. Incorrect
values entered may cause system to malfunction. Also, a very high DRAM
frequency or incorrect DRAM timing may cause system to become un-
stable. When this occurs, revert the item to the default setting.
SERR Signal Condition
This setting specifi es the ECC Error conditions that an SERR# is to be asserted.
The options are None,
Single Bit
, Multiple Bit and Both.
4GB PCI Hole Granularity
This feature allows you to specify the size of PCI hole granularity for a PCI slot.
If MTRRs are not enough, this option may be used to reduce MTRR occupation.
The options are:
256 MB
, 512 MB, 1GB and 2GB.
!
Содержание SUPERSERVER 6015T-INF
Страница 1: ...SUPER SUPERSERVER 6015T T SUPERSERVER 6015T INF USER S MANUAL Revision 1 0b ...
Страница 5: ...v Preface Notes ...
Страница 10: ...x Notes SUPERSERVER 6015T T 6015T INF User s Manual ...
Страница 18: ...1 8 SUPERSERVER 6015T T 6015T INF User s Manual Notes ...
Страница 25: ...Chapter 2 Server Installation 2 7 Figure 2 3 Installing the Server into a Rack ...
Страница 27: ...Chapter 2 Server Installation 2 9 Figure 2 4 Accessing the Inside of the System ...
Страница 32: ...3 4 SUPERSERVER 6015T T 6015T INF User s Manual Notes ...
Страница 62: ...6 6 SUPERSERVER 6015T T 6015T INF User s Manual Figure 6 4 Removing the Power Supply ...
Страница 94: ...A 6 SUPERSERVER 6015T T 6015T INF User s Manual Notes ...
Страница 100: ...B 6 SUPERSERVER 6015T T 6015T INF User s Manual Notes ...
Страница 114: ...D 4 SUPERSERVER 6015T T 6015T INF User s Manual Notes ...