Страница 1: ...USER S MANUAL 1 0 SUPER SUPERSERVER 5026T 3F SUPERSERVER 5026T T...

Страница 2: ...or the resolution of any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to co...

Страница 3: ...l Organization Chapter 1 Introduction The first chapter provides a checklist of the main components included with the server system and describes the main features of the X8ST3 F X8STE motherboard and...

Страница 4: ...jumpers Refer to this chapter when adding or removing processors or main memory and when reconfiguring the motherboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on...

Страница 5: ...v Preface Notes...

Страница 6: ...SATA Subsystem 1 5 Control Panel 1 5 I O Backplane 1 5 Cooling System 1 5 1 4 Contacting Supermicro 1 6 Chapter 2 Server Installation 2 1 Overview 2 1 2 2 Unpacking the System 2 1 2 3 Preparing for Se...

Страница 7: ...trical Safety Precautions 4 1 4 2 General Safety Precautions 4 2 4 3 ESD Precautions 4 3 4 4 Operating Precautions 4 4 Chapter 5 Advanced Serverboard Setup 5 1 Handling the Serverboard 5 1 Precautions...

Страница 8: ...6 2 Control Panel 6 2 6 3 System Fans 6 3 System Fan Failure 6 3 Replacing System Cooling Fans 6 3 6 4 Drive Bay Installation Removal 6 4 Accessing the Drive Bays 6 4 SAS SATA Drive Installation 6 5...

Страница 9: ...ver 5026T 3F 5026T T www supermicro com In addition to the motherboard and chassis various hardware components may have been included with your SuperServer 5026T 3F 5026T T as listed below Four 4 PWM...

Страница 10: ...5026T 3F only Onboard SAS is provided with an LSI 1068E SAS controller chip which supports an 8 port SAS subsystem that supports RAID 0 1 and 10 The SAS drives are hot swappable units Note The operat...

Страница 11: ...tor port and dual Gigabit Ethernet LAN ports and a dedicated IPMI LAN port A second COM port is available as an onboard header Other Features Other onboard features are included to promote system heal...

Страница 12: ...PI Up to 6 40 GT s LPC PCIE_x8 PCI_E x8 on X16 Slot TPM 1 2 IOH W83627DHG PCI 32 X 1 Slots COM1 COM2 Floppy KB MS SPI CK505 CLK SPI EEPROM LGA1366_PROCESSOR Tylersburg 36S FAN x 6 ICH 10R LPC I O DMI...

Страница 13: ...nt system monitoring and control in formation LEDs indicate power on network activity hard disk drive activity and system overheat conditions Also present are a main power button and a system reset bu...

Страница 14: ...ress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Te...

Страница 15: ...if it was damaged in any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the Supe...

Страница 16: ...f the rack are fully extended to the floor with the full weight of the rack resting on them In single rack installation stabilizers should be attached to the rack In multiple rack installations the ra...

Страница 17: ...quipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condi...

Страница 18: ...Rack Rails You should have received two rack rail assemblies with the SuperServer 5026T 3F 5026T T Each of these assemblies consist of three sections an inner fixed chassis rail that secures to the 50...

Страница 19: ...g tab which serves two functions The first is to lock the server into place when installed and pushed fully into the rack which is its normal position Secondly these tabs also lock the server in place...

Страница 20: ...he rack Do this by lining up the rear of the chassis rails with the front of the rack rails Slide the chassis rails into the rack rails keeping the pressure even on both sides you may have to depress...

Страница 21: ...are installing the SuperServer 5026T 3F 5026T T into a Telco type rack follow the directions given on the previous pages for rack installation The only difference in the installation procedure will be...

Страница 22: ...stops You can then lift the top cover from the chassis to gain full access to the inside of the server See Figure 2 5 Checking the Components and Setup You should have one processor already installed...

Страница 23: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System...

Страница 24: ...D ROM and or floppy disk drive to the system Depending upon your system s configuration your system may have one or 3 more drives already installed If you need to install SAS SATA drives please refer...

Страница 25: ...cific components There are also two buttons on the chassis control panel 3 2 Control Panel Buttons There are two push buttons located on the front of the chassis These are in order from left to right...

Страница 26: ...y on and not flashing it indicates an overheat condition which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm Check the routing of the cab...

Страница 27: ...drive failure If one of the SAS drives fail you should be notified by your system management software Please refer to Chapter 6 for instructions on replacing failed SAS drives SATA Drives 5026T T Gre...

Страница 28: ...3 4 SUPERSERVER 5026T 3F 5026T T User s Manual Notes...

Страница 29: ...g power you should first power down the system with the operating system first and then unplug the power cords of all the power supply units in the system When working around exposed electrical circui...

Страница 30: ...om your body which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present Serverboard Battery...

Страница 31: ...use Touch a grounded metal object before removing the board from the antistatic bag Do not let components or PCBs come into contact with your clothing which may retain a charge even if you are wearing...

Страница 32: ...ure that the chassis cover is in place when the 5026T 3F 5026T T is operating to assure proper cooling Out of warranty damage to the system can occur if this practice is not strictly followed Figure 4...

Страница 33: ...nt to handle them very carefully see previous chapter To prevent the serverboard from bending keep one hand under the center of the board to support it when handling The following measures are general...

Страница 34: ...om the back lip of 1 the top cover of the chassis then pull the cover off The X8ST3 F X8STE requires a chassis big enough to support a 12 x 10 2 serverboard such as Supermicro s SC822TQ 400LPB Make su...

Страница 35: ...le JF1 Floppy drive cable Floppy optional 5026T 3F SAS drive data cables SAS1 SAS6 5026T T SATA drive data cables I SATA1 I SATA6 Important Make sure the the cables do not come into contact with the f...

Страница 36: ...gure 5 1 Control Panel Header Pins Figure 5 2 I O Ports NMI x Key Vcc Vcc Vcc Vcc Vcc Vcc Reset Button Power Button Ground x Key Power On LED HDD LED NIC1 LED NIC2 LED OH Fan Fail LED Power Fail LED G...

Страница 37: ...ure on the label area of the fan Notes Always connect the power cord last and always remove it before adding re 1 moving or changing any hardware components Make sure that you install the processor in...

Страница 38: ...e socket or its pins to avoid damaging the CPU or the socket With the CPU in the socket in 4 spect the four corners of the CPU to make sure that it sits level and is properly installed Once the CPU is...

Страница 39: ...he copper core of the heatsink Warning The CPU may over heat if the protective film is not removed from the heatsink Apply the proper amount of ther 5 mal grease on the CPU If your heatsink came with...

Страница 40: ...osened remove the heatsink 5 from the CPU Removing an Active Heatsink Removing the Heatsink Warning We do not recommend removing the CPU or the heatsink If you do need to remove the heatsink please fo...

Страница 41: ...s Insert the desired number of DIMMs into the memory 1 slots starting with DIMM 1A For best performance please use the memory modules of the same type and same speed in the same bank See the DIMM Inst...

Страница 42: ...MM Installation Chart Number of DIMMs 1A 1B 2A 2B 3A 3B 2 X X 4 X X X X 6 X X X X X X Maximum Memory Possible Single Rank UDIMMs 12GB 6x 2GB DIMMs Dual Rank UDIMMs 24GB 6x 4GB DIMMs Notes Both Unbuffe...

Страница 43: ...Card Begin by removing the shield for the PCI slot you wish to populate 1 Fully seat the card into the slot pushing down with your thumbs evenly on 2 both sides of the card Finish by using a screw to...

Страница 44: ...ton T SGPIO1 3 SGPIO2 3 SGPIO1 USB 6 7 USB 4 5 USB3 USB2 Slot 6 PCI E 2 0 x8 in x16 slot Slot 3 PCI E 2 0 x8 I SATA4 I SATA5 Slot 4 PCI E 2 0 x4 in x8 slot Slot 2 PCI 33MHz Slot 5 PCI E 2 0 x8 I SATA2...

Страница 45: ...2 Serial Port Header Fans 1 5 System CPU Fan Headers Fan 1 CPU fan Floppy Floppy Disk Drive Connector I Button I Button for BMC RAID I SATA 0 5 SATA Ports JAR Alarm Reset JD1 Speaker Header Pins 3 4 I...

Страница 46: ...M 18 COM 6 5V 19 COM 7 COM 20 Res NC 8 PWR_OK 21 5V 9 5VSB 22 5V 10 12V 23 5V 11 12V 24 COM 12 3 3V Reset Button Pin Definitions JF1 Pin Definition 3 Reset 4 Ground Power Button Pin Definitions JF1 Pi...

Страница 47: ...JLAN2 LED The LED connections for JLAN2 are on pins 9 and 10 of JF1 Attach an LED cable to display network activ ity See the table on the right for pin definitions NIC1 LED Pin Definitions JF1 Pin Def...

Страница 48: ...rd port See the table on the right for pin definitions NMI Button The non maskable interrupt button header is located on pins 19 and 20 of JF1 Refer to the table on the right for pin definitions NMI B...

Страница 49: ...2 Ground Wake On LAN Pin Definitions JWOL Pin Definition 1 5V Standby 2 Ground 3 Wake up LAN1 2 Ethernet Ports Two Ethernet ports designated LAN1 and LAN2 are located beside the VGA port on the I O ba...

Страница 50: ...chip in the system See the table on the right for pin definitions SGPIO Header Pin Definitions T SGPIO 0 1 3 SGPIO 0 1 Pin Definition Pin Definition 1 NC 2 NC 3 Ground 4 DATA Out 5 Load 6 Ground 7 Clo...

Страница 51: ...l Power SMB Header Pin Definitions SMB_PS1 Pin Definition 1 Clock 2 Data 3 PWR Fail 4 Ground 5 3 3V SMB Power Supply Connector The SMB Power Supply I2 C connec tor is designated SMB_PS1 Connect the ap...

Страница 52: ...3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS...

Страница 53: ...2 3 Disabled SMBus to PCI Slots Jumper Settings JI2 C1 JI2 C2 Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Default Disabled USB Wake Up Use JPUSB jumpers to wake up your system by pressing a ke...

Страница 54: ...Disabled SAS Enable Disable X8ST3 F Only JPS1 allows you to enable or disable SAS Connectors The default position is on pins 1 and 2 to enable SAS See the table on the right for jumper settings Softw...

Страница 55: ...hen the system is on Be sure to unplug the power cable before removing or adding any components See the table on the right for more details Onboard Power LED Indicator LE1 LED Color Definition Off Sys...

Страница 56: ...nd 12 Drive Select B 13 Ground 14 Drive Select B 15 Ground 16 Motor Enable 17 Ground 18 DIR 19 Ground 20 STEP 21 Ground 22 Write Data 23 Ground 24 Write Gate 25 Ground 26 Track 00 27 Ground 28 Write P...

Страница 57: ...are eight SAS ports included on the motherboard See the table on the right for pin definitions Note JPS1 must be set cor rectly to enable the SAS con troller SAS Port Pin Definitions SAS0 SAS7 Pin Def...

Страница 58: ...kaged with your motherboard Driver Tool Installation Display Screen Note Click the icons showing a hand writing on paper to view the readme files for each item Click the computer icons to the right of...

Страница 59: ...ial system information such as CPU temperature system voltages and fan status See the Figure below for a display of the Supero Doctor III interface Note The default User Name and Password for SuperDoc...

Страница 60: ...ware Revision 1 0 can be downloaded from our Web Site at ftp ftp supermicro com utility Supero_Doctor_III You can also download the SDIII User s Guide at http www supermicro com PRODUCT Manuals SDIII...

Страница 61: ...very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded m...

Страница 62: ...Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out of the airflow path The LEDs inform you of system status See Chapter 3 System Interface for details on the LEDs...

Страница 63: ...ue to run with a failed fan Re move the top chassis cover while the system is still running to determine which of the four fans has failed Replacing System Cooling Fans Removing a Fan Remove the chass...

Страница 64: ...ppy Disk Drive For installing removing the CD ROM or floppy disk drive you will need to gain access to the inside of the server by removing the top cover of the chassis Proceed to the CD ROM and Flopp...

Страница 65: ...drive into the carrier with the printed circuit 1 board side toward the carrier so that the mounting holes align with those in the carrier Secure the drive to the carrier with four screws as shown in...

Страница 66: ...ton Installing Removing SAS SATA Drives The SAS SATA drive bays are located in the front of the chassis and are hot swap units meaning that they can be installed and removed while the system is run ni...

Страница 67: ...ive carrier and 1 screw them into both sides of the CD ROM drive using the holes provided Slide the CD ROM into the bay and secure it to the chassis with the drive 2 carrier screws you first removed A...

Страница 68: ...e Power Supply First shut down the system then unplug the power cord 1 Remove the chassis cover by pressing the two release buttons on the top of 2 the chassis near the front then push the chassis top...

Страница 69: ...not be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the le...

Страница 70: ...n by selecting the Main tab on the top of the screen The Main BIOS Setup screen is shown below System Overview The following BIOS information will be displayed System Time System Date Use this option...

Страница 71: ...hour format For example 5 30 P M appears as 17 30 00 AMIBIOS Version Build Date Processor The AMI BIOS will automatically display the status of processor as shown below Speed Physical Count Logical Co...

Страница 72: ...the bootup screen options to be modified between POST mes sages or the OEM logo Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST messages...

Страница 73: ...t handles the boot disk function When this item is set to Enabled the ROM BIOS of the host adaptors will capture Interrupt 19 at boot and allow the drives that are attached to these host adaptors to f...

Страница 74: ...alization Technology to allow one platform to run multiple operating systems and applications in independent partitions creat ing multiple virtual systems in one physical computer The options are Enab...

Страница 75: ...ow indicate that an Intel Core i7 processor 965 Extreme Edition is installed 1 Core Ratio Limit This increases multiplies the processor s core 1 clock speed in relation to the bus speed The default se...

Страница 76: ...ore i7 processors this is the lowest C State supported C1E Support Select Enabled to use the Enhanced Halt State feature C1E significantly reduces the CPU s power consumption by reducing the CPU s clo...

Страница 77: ...dvanced Settings submenu are listed below QPI and IMC Configuration QuickPath Interconnect QPI is the connection between the CPU and the motherboard s I O hub Use this feature to modify speed and powe...

Страница 78: ...s the North Bridge to correct correctable memory errors detected on a memory module and send the correction to the re questor the original source When this item is set to Enabled the North Bridge will...

Страница 79: ...h The default is 400 Press or on your keyboard to change this value Performance Tuning Mode Available when both XMP memory and an Extreme Edition CPU are installed This item allows the user to choose...

Страница 80: ...ignal transactions between L0 and L1 Links on the PCI Express Bus This maximizes power saving and transaction speed The options are Enabled and Disabled USB Functions This feature allows the user to d...

Страница 81: ...AHCI ICH RAID CodeBase Available if RAID is selected above Select Intel to enable the Intel SATA Host RAID Utility Select Adaptec to use the Adaptec Host RAID Utility The options are Intel and Adaptec...

Страница 82: ...Mode boosts the IDE drive performance by increasing the amount of data transferred Only 512 bytes of data can be transferred per interrupt if Block Mode is not used Block Mode allows transfers of up...

Страница 83: ...DMA mode 2 It has a data transfer rate of 16 6 MBs Select UDMA0 to allow the BIOS to use Ultra DMA mode 0 It has a data transfer rate of 16 6 MBs It has the same transfer rate as PIO mode 4 and Multi...

Страница 84: ...system PCI Latency Timer This feature sets the latency Timer of each PCI device installed on a PCI bus Select 64 to set the PCI latency to 64 PCI clock cycles The options are 32 64 96 128 160 192 224...

Страница 85: ...SK IR Amplitude Shifted Keying Infra Red is a protocol compatible with Sharp branded PDAs and other infra red devices Floppy Controller Select Enabled to enable the onboard Floppy Controller The optio...

Страница 86: ...Delay 4 Sec XHardware Health Configuration This feature allows the user to monitor Hardware Health of the system and review the status of each item when displayed CPU Overheat Alarm This option allows...

Страница 87: ...Reading This feature displays the fan speed readings from fan interfaces Fan1 through Fan5 Vcore 3 3Vcc 12V V_DIMM 5V 12V 3 3VSB and VBAT XACPI Configuration Use this feature to configure Advanced Con...

Страница 88: ...View BMC System Event Log This feature is used to view any BMC events It shows the total number of entries and will allow the viewing of each event by scrolling down on an Entry Number and pressing En...

Страница 89: ...on Diagnostic Interface Alert Startup Delay This feature inserts a delay during startup for PEF alerts The options are Enabled and Disabled PEF Alert Startup Delay This sets the pre determined time to...

Страница 90: ...cted The options are 5 Min 1 Min 30 Sec and 10 Sec IPMI Virtual Device Allows the system to simulate connection to an IPMI device using a media image The options are Disabled and Enabled XEvent Log Co...

Страница 91: ...has not been used and Set means a user password has been entered for the system Change Supervisor Password Select this feature and press Enter to access the submenu and then type in a new Supervisor...

Страница 92: ...led 1st boot device 1st Floppy Drive 2nd boot device CD DVD XXXXXXXXXX 3rd boot device SATA XXXXXXXXX Clear User Password Available only if User Password has been set Password Check Available options...

Страница 93: ...con figuration parameters can take effect Select Save Changes and Exit from the Exit menu and press Enter XRemovable Drives This feature allows the user to specify the boot sequence from available Rem...

Страница 94: ...to the AMI BIOS Utility Program Load Optimal Defaults To set this feature select Load Optimal Defaults from the Exit menu and press Enter Then select OK to allow the AMI BIOS to automatically load Opt...

Страница 95: ...minal This section lists Beep Codes for recoverable POST errors Recoverable POST Error Beep Codes When a recoverable type of error occurs during POST BIOS will display a POST code that describes the p...

Страница 96: ...A 2 SUPERSERVER 5026T 3F 5026T T User s Manual Notes...

Страница 97: ...et BIOS 16 Mb Phoenix Flash ROM Memory Capacity Six 240 pin DIMM slots to support up to 24 GB of unbuffered ECC or non ECC DDR3 1333 1066 800 SDRAM Note See the memory section in Chapter 5 for details...

Страница 98: ...Supply Rated Output Power 400W Part PWS 401 2H Rated Output Voltages 3 3V 25A 5V 30A 12V 32A 12V 0 5A 5Vsb 4A Chassis Model SC822TQ 400LPB Form Factor 2U rackmount Dimensions WxHxD 16 7 x 3 5 x 25 7...

Страница 99: ...ety EN 60950 IEC 60950 Compliant UL Listed USA CUL Listed Canada TUV Certified Germany CE Marking Europe California Best Management Practices Regulations for Perchlorate Materials This Perchlorate war...

Страница 100: ...perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell suc...