background image

®

   

S

UPER

USER’S MANUAL

Revision 1.0a

S

UPER

S

ERVER

 5016T-TB

Содержание SUPERSERVER 5016T-TB

Страница 1: ...SUPER USER S MANUAL Revision 1 0a SUPERSERVER 5016T TB...

Страница 2: ...for the resolution of any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to c...

Страница 3: ...811TS 280B chassis Chapter 2 Server Installation This chapter describes the steps necessary to install the SuperServer 5016T TB into a rack and check out the server configuration prior to powering up...

Страница 4: ...dvanced Chassis Setup Refer to Chapter 6 for detailed information on the SC811TS 280B 1U rackmount server chassis You should follow the procedures given in this chapter when install ing removing or re...

Страница 5: ...v Preface Notes...

Страница 6: ...ro 1 5 Chapter 2 Server Installation 2 2 Unpacking the System 2 1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 2 Rack Mounting Considerations 2 3 Ambient Operating Temperature 2 3 Reduced A...

Страница 7: ...onnecting Power Cables 5 3 Connecting the Control Panel 5 3 5 4 I O Ports 5 4 5 5 Installing the Processor and Heatsink 5 5 Installing an LGA1366 Processor 5 5 Installing a Passive CPU Heatsink 5 7 Re...

Страница 8: ...ader 5 18 Onboard Power LED 5 18 Power Supply Fail LED Header 5 19 Alarm Reset 5 19 I Button 5 19 Unit Identifier Button 5 19 5 10 Jumper Settings 5 20 Explanation of Jumpers 5 20 CMOS Clear 5 20 VGA...

Страница 9: ...Power Cables 6 6 DVD ROM Drive Installation 6 6 Power Supply Failure 6 7 Chapter 7 BIOS 7 1 Introduction 7 1 Starting BIOS Setup Utility 7 1 How To Change the Configuration Data 7 1 Starting the Setup...

Страница 10: ...Notes SUPERSERVER 5016T TB User s Manual x...

Страница 11: ...th the 5016T TB as listed below One CPU heatsink SNK P0037P Two 10 cm blower fans FAN 0038L4 One air shroud MCP 310 18009 0N One slim DVD ROM drive DVM TEAC DVD SBT One internal USB cable for DVD ROM...

Страница 12: ...C DDR2 1333 1066 800 SDRAM Onboard SATA A SATA controller is built in to the ICH10R portion of the chipset to provide support for a six port 3 Gb sec Serial ATA subsystem The SATA drives are hot swapp...

Страница 13: ...1 1 Intersil QPI Up to 6 40 GT s PCI E x16 PCI E Gen2 x16 X58 W83627DHG COM1 COM2 Floppy Kybd Mouse SPI SPI EEPROM ICH10R LPC I O DMI 3 Gb s SATA USB x8 SATA x6 USB 2 0 DDR3 1333 1066 800 LGA1366 CPU...

Страница 14: ...portant system monitoring and control information LEDs indicate power on network activity hard disk drive activ ity and system overheat conditions The control panel also includes a main power button a...

Страница 15: ...per Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical...

Страница 16: ...1 6 SUPERSERVER 5016T TB User s Manual Notes...

Страница 17: ...maged in any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the SuperServer 5016T...

Страница 18: ...utions Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them In a single rack installation stabilizers should be att...

Страница 19: ...ble with the manufacturer s maximum rated ambient tempera ture Tmra Reduced Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised...

Страница 20: ...he Sections of the Rack Rails You should have received two rack rail assemblies with the SuperServer 5016T TB Each of these assemblies consist of two sections an inner fixed chassis rail that secures...

Страница 21: ...ce when installed and pushed fully into the rack which is its normal position Secondly these tabs also lock the server in place when fully extended from the rack This prevents the server from coming c...

Страница 22: ...it The next step is to install the server into the rack Do this by lining up the rear of the chassis rails with the front of the rack rails Slide the chassis rails into the rack rails keeping the pres...

Страница 23: ...Telco type rack follow the directions given on the previous pages for rack installation The only difference in the installation procedure will be the positioning of the rack brackets to the rack They...

Страница 24: ...e 3 inside of the server Checking the Components You may have one or two processors already installed into the system board 1 Each processor should have its own heatsink attached See Chapter 5 for ins...

Страница 25: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System...

Страница 26: ...al ATA drives already installed If you need to install Serial ATA drives please refer to the appropriate section in Chapter 6 Checking the Airflow Airflow is provided by two 10 cm input fans The syste...

Страница 27: ...re are two push buttons located on the front of the chassis These are in order from left to right a reset button and a power on off button Reset Button The reset button reboots the system Power This i...

Страница 28: ...cables and make sure all fans are present and operating normally You should also check to make sure that the chassis covers are installed Finally verify that the heatsinks are installed properly see C...

Страница 29: ...n LED When illuminated this green LED on the front of the SATA drive carrier indicates drive activity A connection to the SATA backplane enables this LED to blink on and off when that particular drive...

Страница 30: ...3 4 SUPERSERVER 5016T TB User s Manual Notes...

Страница 31: ...wer you should first power down the system with the operating system first and then unplug the power cords of all the power supply units in the system When working around exposed electrical circuits a...

Страница 32: ...are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present Serverboard Battery CAUTION There is a...

Страница 33: ...use Touch a grounded metal object before removing the board from the antistatic bag Do not let components or PCBs come into contact with your clothing which may retain a charge even if you are wearing...

Страница 34: ...ice is not strictly followed Figure 4 1 Installing the Onboard Battery LITHIUM BATTERY BATTERY HOLDER Please handle used batteries carefully Do not damage the battery in any way a damaged battery may...

Страница 35: ...handle them very carefully see previous chapter To prevent the serverboard from bending keep one hand under the center of the board to support it when handling The following measures are generally su...

Страница 36: ...uires a chassis big enough to support a 12 x 9 6 serverboard 2 such as Supermicro s SC811TS 280B Make sure that the I O ports on the serverboard align properly with their 3 respective holes in the I O...

Страница 37: ...tions Control Panel cable JF1 COM Port cable COM2 Front USB port cable USB2 3 SATA drive data cables SATA0 SATA1 Important Make sure the the cables do not come into contact with the fans Connecting Po...

Страница 38: ...arious I O ports Figure 5 1 Control Panel Header Pins Figure 5 2 I O Ports NMI x Key Vcc Vcc Vcc Vcc Vcc UID LED Vcc Reset Button Power Button Ground x Key Power On LED HDD LED UID Switch NIC1 LED NIC...

Страница 39: ...ure on the label area of the fan Notes Always connect the power cord last and always remove it before adding re 1 moving or changing any hardware components Make sure that you install the processor in...

Страница 40: ...cket or its pins to avoid damaging the CPU or the socket With the CPU in the socket in 4 spect the four corners of the CPU to make sure that it sits level and is properly installed Once the CPU is sec...

Страница 41: ...to the heatsink or the CPU die the required amount has al ready been applied Place the heatsink on top 1 of the CPU so that the four mounting holes are aligned with those on the retention mechanism In...

Страница 42: ...Using a screwdriver loosen and 3 remove the heatsink screws from the motherboard in the sequence as show in the previ ous section 1 and 2 followed by 3 and 4 Hold the heatsink as shown 4 in the pictur...

Страница 43: ...the memory 1 slots starting with DIMM 1A For best performance please use the memory modules of the same type and same speed in the same bank See the DIMM Installation Chart on the following page Note...

Страница 44: ...RAM density Memory Population UDIMM 3 DIMMs per Channel Routing DIMM Slots per Channel DIMMs Populated per Channel DIMM Type POR Speeds in MHz Ranks per DIMM any combination SR Single Rank DR Dual Ran...

Страница 45: ...op of the card shield to the chassis 3 The PCI slot shield protects the serverboard and its components from EMI and aid in proper ventilation so make sure it is always in place Possible System Memory...

Страница 46: ...5 12 SUPERSERVER 5016T TB User s Manual Figure 5 4 X8STi Layout not drawn to scale 5 8 Serverboard Details Notes Jumpers not indicated are for test purposes only...

Страница 47: ...Port Header FAN 1 6 Chassis CPU Fan Headers Floppy Floppy Disk Drive Connector I Button I Button Socket for RAID 5 support I SATA0 I SATA5 SATA Ports JAR Alarm Reset Header JD1 Speaker Header JF1 Fro...

Страница 48: ...20 Res NC 8 PWR_OK 21 5V 9 5VSB 22 5V 10 12V 23 5V 11 12V 24 COM 12 3 3V Reset Button Pin Definitions JF1 Pin Definition 3 Reset 4 Ground Power Button Pin Definitions JF1 Pin Definition 1 Power Signal...

Страница 49: ...Definition 13 Vcc 14 HD Active NIC2 JLAN2 LED The LED connections for JLAN2 are on pins 9 and 10 of JF1 Attach an LED cable to display network activ ity See the table on the right for pin definitions...

Страница 50: ...he table on the right for pin definitions NMI Button The non maskable interrupt button header is located on pins 19 and 20 of JF1 Refer to the table on the right for pin definitions NMI Button Pin Def...

Страница 51: ...ignated LAN1 and LAN2 are located beside the VGA port on the I O backplane These ports accept RJ45 type cables External Speaker Internal Buzzer On the JD1 header pins 1 4 are for an external speaker a...

Страница 52: ...the backplane See the table on the right for pin defini tions SGPIO Header Pin Definitions T SGPIO 0 T TGPIO 1 Pin Definition Pin Definition 1 NC 2 NC 3 Ground 4 DATA Out 5 Load 6 Ground 7 Clock 8 NC...

Страница 53: ...y to JPWF to provide a warning of power supply failure This warning sig nal is passed through the PWR_LED pin to indicate of a power failure on the chassis See the table on the right for pin definitio...

Страница 54: ...1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS Fir...

Страница 55: ...Dog must also be en abled in BIOS Note When enabled the user needs to write their own application software in order to disable the Watch Dog Timer Watch Dog Jumper Settings JWD Jumper Setting Definiti...

Страница 56: ...BMC Enable Disable Jumper Settings JBMC1 Settings Definition Pins 1 2 Enabled Pins 2 3 Disabled BMC Enable Disable The JBMC1 jumper allows the user to enable or disable the BMC Base board Management...

Страница 57: ...ee the table on the right for more details Onboard Power LED Indicator LE1 LED Color Definition Off System Off power cable not connected Green System on or power cable connected BMC Heartbeat LED A BM...

Страница 58: ...Ground 10 Motor Enable 11 Ground 12 Drive Select B 13 Ground 14 Drive Select B 15 Ground 16 Motor Enable 17 Ground 18 DIR 19 Ground 20 STEP 21 Ground 22 Write Data 23 Ground 24 Write Gate 25 Ground 2...

Страница 59: ...ed with your motherboard Driver Tool Installation Display Screen Note Click the icons showing a hand writing on paper to view the readme files for each item Click the computer icons to the right of th...

Страница 60: ...al system information such as CPU temperature system voltages and fan status See the Figure below for a display of the Supero Doctor III interface Note The default User Name and Password for SuperDoct...

Страница 61: ...ded from our Web Site at ftp ftp supermicro com utility Supero_Doctor_III You can also download the SDIII User s Guide at http www supermicro com PRODUCT Manuals SDIII UserGuide pdf For Linux we will...

Страница 62: ...5 28 SUPERSERVER 5016T TB User s Manual Notes...

Страница 63: ...prevent damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD discharge Precaution...

Страница 64: ...ese wires have been bundled together in a ribbon cable to simplify the connection Connect the cable from JF1 on the serverboard to JP4 on the Control Panel PCB printed circuit board Make sure the red...

Страница 65: ...eat LED on the control panel You will need to power down the system to replace this fan with one of the same type p n FAN 0038L4 Contact your vendor or Supermicro for information on replacement fans R...

Страница 66: ...te Only a slim DVD ROM drive will fit into the 5016T TB Serial ATA Drive Installation The SATA drives are mounted in drive carriers to simplify their installation and removal from the chassis These ca...

Страница 67: ...uit board side toward the 1 carrier so that the mounting holes align with those in the carrier Secure the drive to the carrier with four screws as shown in Figure 6 3 2 Installing Removing SATA Drives...

Страница 68: ...sp the two handles on either side and pull the unit straight out until it 3 locks you will hear a click Depress the two buttons on the top of the chassis to release the top cover 4 and at the same tim...

Страница 69: ...er side and pull the unit straight out until it 3 locks you will hear a click Depress the two buttons on the top of the chassis to release the top cover 4 and at the same time push the cover away from...

Страница 70: ...6 8 SUPERSERVER 5016T TB User s Manual Notes...

Страница 71: ...be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left f...

Страница 72: ...selecting the Main tab on the top of the screen The Main BIOS Setup screen is shown below System Overview The following BIOS information will be displayed System Time System Date Use this option to c...

Страница 73: ...at For example 5 30 P M appears as 17 30 00 AMIBIOS Version Build Date Processor The AMI BIOS will automatically display the status of processor as shown below Type of Processor Speed Physical Count L...

Страница 74: ...bootup screen options to be modified between POST mes sages or the OEM logo Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST messages The...

Страница 75: ...pt 19 at boot and allow the drives that are attached to these host adaptors to function as bootable disks If this item is set to Disabled the ROM BIOS of the host adap tors will not capture Interrupt...

Страница 76: ...n one physical computer The options are Enabled and Disabled Note If there is any change to this setting you will need to power off and restart the system for the change to take effect Please refer to...

Страница 77: ...ting is 26 Press or on your keyboard to change this value 2 3 Core Ratio Limit This increases the processor s core 2 3 clock speeds in relation to the bus speed The default setting is 25 Press or on y...

Страница 78: ...stalled on an add on card or a network card to handle some or all packet processing of this add on card For this moth erboard the TOE device is built inside the ESB 2 South Bridge chip This feature is...

Страница 79: ...orth Bridge to correct correctable memory errors found on a memory module When the CPU or I O issues a demand read command and the read data from memory turns out to be a correctable error the error i...

Страница 80: ...nd correct DIMM velocity based on the altitude where the system is located in order to improve DIMM thermal performance Altitude is defined as the number of feet above the sea level where the computer...

Страница 81: ...are Disabled and Enabled Active State Power Management Select Enabled to start Active State Power Management for signal transactions between L0 and L1 Links on the PCI Express Bus This maximizes powe...

Страница 82: ...ected above Select Intel to enable the Intel SATA Host RAID Utility Select Adaptec to use the Adaptec Host RAID Utility The options are Intel and Adaptec Max Ports on SATA 1 Available if either RAID o...

Страница 83: ...KB per interrupt Select Disabled to allow data to be transferred from and to the device one sector at a time Select Auto to allow data transfer from and to the device occur multiple sectors at a time...

Страница 84: ...transfer rate of 16 6 MBs It has the same transfer rate as PIO mode 4 and Multi Word DMA mode 2 Select UDMA1 to allow the BIOS to use Ultra DMA mode 1 It has a data transfer rate of 25 MBs Select UDMA...

Страница 85: ...ncy to 64 PCI clock cycles The options are 32 64 96 128 160 192 224 and 248 PCI IDE Bus Master When enabled the BIOS uses PCI bus mastering for reading writing to IDE drives The options are Disabled a...

Страница 86: ...ices ASK IR Amplitude Shifted Keying Infra Red is a protocol compatible with Sharp branded PDAs and other infra red devices Floppy Controller Select Enabled to enable the onboard Floppy Controller The...

Страница 87: ...Hardware Health of the system and review the status of each item when displayed CPU Overheat Alarm This option allows the user to select the CPU Overheat Alarm setting which de termines when the CPU...

Страница 88: ...ol TControl 100 C PECI Count TControl CPU Temperature Setting High When CPU PECI count is greater than TControl TControl PECI Count Notes According to Intel s specifications PECI and TControl are defi...

Страница 89: ...V 12V 3 3VSB and VBAT XACPI Configuration Use this feature to configure Advanced Configuration and Power Interface ACPI power management settings for your system USB Device WakeUp This feature is used...

Страница 90: ...atus of TPM Ownership XIPMI Configuration X8STi F X8STi 3F Only Intelligent Platform Management Interface IPMI is a set of common interfaces that IT administrators can use to monitor system health and...

Страница 91: ...wo digit hexa decimal numbers Base 16 0 9 A B C D E F separated by dots i e 00 30 48 D0 D4 60 Subnet Mask Subnet masks tell the network which subnet this machine be longs to The value of each three di...

Страница 92: ...options are Disabled and Enabled BMC Watch Dog Timer Action Allows the BMC to reset or power down the system if the operating system hangs or crashes The options are Disabled Reset System Power Down P...

Страница 93: ...has not been used and Set means a user password has been entered for the system Change Supervisor Password Select this feature and press Enter to access the submenu and then type in a new Supervisor...

Страница 94: ...1st Floppy Drive 2nd Boot Device USB XXXXXXXXX 3rd Boot Device SATA XXXXXXXXX 4th Boot Device Network XXXXXXXXX 5th Boot Device Network XXXXXXXXX Clear User Password Available only if User Password ha...

Страница 95: ...allows the user to specify the boot sequence from all available hard disk drives The settings are Disabled and a list of all hard disk drives that have been detected i e 1st Drive 2nd Drive 3rd Drive...

Страница 96: ...ss Enter to discard all the changes and return to the AMI BIOS Utility Program Load Optimal Defaults To set this feature select Load Optimal Defaults from the Exit menu and press Enter Then select OK...

Страница 97: ...al This section lists Beep Codes for recoverable POST errors Recoverable POST Error Beep Codes When a recoverable type of error occurs during POST BIOS will display a POST code that describes the prob...

Страница 98: ...A 2 SUPERSERVER 5016T TB User s Manual Notes...

Страница 99: ...ress F6 if you need to install a third 2 party SCSI or RAID driver displays When the Windows XP 2003 Setup screen appears press S to specify ad 3 ditional device s Insert the driver diskette Intel AA...

Страница 100: ...er key to proceed with the installation process If you need 5 to specify any additional devices to be installed do it at this time Once all devices are specified press the Enter key to continue with t...

Страница 101: ...upported processors Chipset Intel X58 ICH10R chipset BIOS 4 Mb AMI SPI Flash ROM Memory Capacity Six 240 pin DIMM slots that can support up to 24 GB of unbuffered ECC non ECC DDR2 1333 1066 800 SDRAM...

Страница 102: ...Temperature 40 to 70 C 40 to 158 F Operating Relative Humidity 8 to 90 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class...

Страница 103: ...anagement Practices Regulations for Perchlorate Materials This Perchlorate warning applies only to products containing CR Manganese Dioxide Lithium coin cells Perchlorate Material special handling may...

Страница 104: ...form be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such pr...

Отзывы: