2-4
S
UPER
S
ERVER 5015M-MT/5015M-MT+ User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the SuperServer 5015M-MT/5015M-
MT+ into a rack unit with the rack rails provided. If the server has already been
mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a
variety of rack units on the market, which may mean the assembly procedure will
differ slightly. You should also refer to the installation instructions that came with
the rack unit you are using.
Identifying the Sections of the Rack Rails
You may have received rack rail hardware with the SuperServer 5015M-MT/5015M-
MT+. (Two front inner rails should already be attached to the chassis.) This
hardware consists of two rear inner rails that secure to the chassis, one on each
side just behind the preinstalled front inner rails. Note that these two rails are
left/right specifi c.
Installing the Rear Inner Rails
First, locate the right rear inner rail (the rail that will be used on the right side of
the chassis when you face the front of the chassis). Align the two square holes
on the rail against the hooks on the right side of the chassis. Securely attach the
rail to the chassis with M4 fl at head screws. Repeat these steps to install the left
rear inner rail to the left side of the chassis (see Figure 2-1). You will also need to
attach the rail brackets when installing into a telco rack.
Locking Tabs:
Both chassis rails have a locking tab, which serves two functions.
The fi rst is to lock the server into place when installed and pushed fully into the
rack, which is its normal position. Secondly, these tabs also lock the server in place
when fully extended from the rack. This prevents the server from coming completely
out of the rack when you pull it out for servicing.
Содержание SuperServer 5015M-MT
Страница 1: ...SUPER SUPERSERVER 5015M MT SUPERSERVER 5015M MT USER S MANUAL Revision 1 0b...
Страница 5: ...v Preface Notes...
Страница 10: ...x Notes SUPERSERVER 5015M MT 5015M MT User s Manual...
Страница 25: ...Chapter 2 Server Installation 2 9 Figure 2 4 Accessing the Inside of the System...
Страница 30: ...3 4 SUPERSERVER 5015M MT 5015M MT User s Manual Notes...
Страница 58: ...5 24 SUPERSERVER 5015M MT 5015M MT User s Manual Notes...
Страница 66: ...6 8 SUPERSERVER 5015M MT 5015M MT User s Manual Notes...
Страница 88: ...7 22 SUPERSERVER 5015M MT 5015M MT User s Manual Notes...
Страница 90: ...A 2 SUPERSERVER 5015M MT 5015M MT User s Manual Notes...
Страница 96: ...B 6 SUPERSERVER 5015M MT 5015M MT User s Manual Notes...
Страница 114: ...C 18 SUPERSERVER 5015M MT 5015M MT User s Manual Notes...
Страница 118: ...D 4 SUPERSERVER 5015M MT 5015M MT User s Manual Notes...