B-2
SUPERSERVER 2027TR-D70RF+ USER'S MANUAL
Chassis
SC217HD-R1K28MB (2U rackmount)
Dimensions: (WxHxD) 17.25 x 3.47 x 26.75 in. (438 x 88 x 679 mm)
Weight
Gross (Bare Bone): 85 lbs. (38.6 kg.)
System Cooling
The SuperServer 2027TR-D70RF+ has four (4) 8-cm PWM system cooling fans
System Input Requirements
AC Input Voltage: 85-264V AC auto-range
Rated Input Current: 13 - 5.5A
Rated Input Frequency: 47 to 63 Hz
Effi ciency: 80+ (Platinum Level)
Power Supply
Rated Output Power: 1280 Watt (Part# PWS-1K28P-SQ)
Rated Output Voltages: +12V (106.7A@180-260V, 83A@85-140V), +5Vsb (4A)
Operating Environment
Operating Temperature: 0º to 35º C (32º to 95º F)
Non-operating Temperature: -10º to 60º C (-14º to 140º F)
Operating Relative Humidity: 20% to 95% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-
3, CISPR 22 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and
Canada), CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply.
See
www.dtsc.ca.gov/hazardouswaste/perchlorate
” for further details.
Содержание SUPERSERVER 2027TR-D70RF+
Страница 1: ...SUPER SUPERSERVER Revision 1 0 SUPERSERVER 2027TR D70RF...
Страница 5: ...v SUPERSERVER 2027TR D70RF SUPERSERVER Notes...
Страница 10: ...x Notes SUPERSERVER 2027TR D70RF SUPERSERVER...
Страница 30: ...2 12 SUPERSERVER 2027TR D70RF USER S MANUAL Notes...
Страница 34: ...SUPERSERVER 2027TR D70RF USER S MANUAL 3 4 Notes...
Страница 54: ...4 20 SUPERSERVER servername User s Manual Notes...
Страница 82: ...5 28 SUPERSERVER 2027TR D70RF USER S MANUAL Notes...
Страница 89: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 6 Replacing a System Fan in the Fan Housing...
Страница 96: ...6 14 SUPERSERVER 2027TR D70RF USER S MANUAL Figure 6 13 Removing a System Node 1 3 1 2 1 2...
Страница 138: ...7 34 SUPERSERVER 2027TR D70RF USER S MANUAL Notes...
Страница 140: ...A 2 SUPERSERVER 2027TR D70RF USER S MANUAL Notes...
Страница 143: ...B 3 Appendix B System Specifications Notes...