Chapter 2: Server Installation
2-5
2-4 Rack Mounting Instructions
This section provides information on installing the SC217 chassis into a rack unit
with the quick-release rails provided. There are a variety of rack units on the market,
which may mean the assembly procedure will differ slightly. You should also refer to
the installation instructions that came with the rack unit you are using.
Note:
This rail will fi t a rack between 26" and 33.5" deep.
Separating the Sections of the Rack Rails
The chassis package includes two rail assemblies in the rack mounting kit. Each
assembly consists of two sections: an inner fi xed chassis rail that secures directly
to the server chassis and an outer fi xed rack rail that secures directly to the rack
itself.
Figure 2-2. Separating the Rack Rails
1
1
1
2
1
4
1
3
Separating the Inner and Outer Rails
Locate the rail assembly in the chassis
1.
packaging.
Extend the rail assembly by pulling it
2.
outward.
Press the quick-release tab.
3.
Separate the inner rail extension from
4.
the outer rail assembly.
Rail Assembly
Extending the Rails
Quick-
Release Tab
Separating
the Inner Rail
Extension
Содержание SuperServer 2026TT-DLIBQRF
Страница 1: ...SUPER USER S MANUAL Revision 1 0 SuperServer 2026TT DLRF 2026TT DLIBXRF 2026TT DLIBQRF...
Страница 5: ...v Preface Notes...
Страница 16: ...1 8 SUPERSERVER 2026TT DLRF DLIBXRF DLIBQRF User s Manual Notes...
Страница 27: ...Chapter 2 Server Installation 2 11 Figure 2 6 Removing a Node from the System 1 1 1 1 1 2 1 2 1 1...
Страница 28: ...2 12 SUPERSERVER 2026TT DLRF DLIBXRF DLIBQRF User s Manual Notes...
Страница 32: ...3 4 SUPERSERVER 2026TT DLRF DLIBXRF DLIBQRF User s Manual Notes...
Страница 68: ...6 10 SUPERSERVER 2026TT DLRF DLIBXRF DLIBQRF User s Manual Figure 6 8 Removing the Power Supply Release Tab...
Страница 100: ...A 2 SUPERSERVER 2026TT DLRF DLIBXRF DLIBQRF User s Manual Notes...