S

UPER

S

ERVER 

 

1027R-72RFTP

   

S

UPER

®

USER’S MANUAL

 

 

1.0a

Содержание SUPERSERVER 1027R-72RFTP

Страница 1: ...SUPERSERVER 1027R 72RFTP SUPER USER S MANUAL 1 0a...

Страница 2: ...any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits...

Страница 3: ...or to powering up the system If your server was ordered without processor and memory components this chapter will refer you to the appropriate sections of the manual for their installation Chapter 3 S...

Страница 4: ...low the procedures given in this chapter when installing removing or reconfiguring SAS or peripheral drives and when replacing system power supply modules and cooling fans Chapter 7 BIOS The BIOS chap...

Страница 5: ...v Preface Notes...

Страница 6: ...er Installation 2 1 Overview 2 1 2 2 Unpacking the System 2 1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 1 2 4 Warnings and Precautions 2 2 Rack Precautions 2 2 Server Precautions 2 2 Rac...

Страница 7: ...tallation 4 8 Restricted Area 4 9 Battery Handling 4 10 Redundant Power Supplies 4 12 Backplane Voltage 4 13 Comply with Local and National Electrical Codes 4 14 Product Disposal 4 15 Hot Swap Fan War...

Страница 8: ...es 6 1 Precautions 6 1 6 2 Control Panel 6 2 6 3 System Fans 6 2 System Fan Failure 6 2 Air Shroud 6 4 Hard Drive Installation 6 7 Hard Drive Backplane 6 9 DVD ROM Drive Installation 6 9 6 4 Power Sup...

Страница 9: ...s hardware components have been included with the 1027R 72RFTP as listed below Six sets of 4 cm counter rotating fans FAN 0101L4 One air shroud and one air baffle MCP 310 19003 0N MCP 310 19013 0B Two...

Страница 10: ...support eight SAS 2 0 ports The hot swap SAS drives are connected to a backplane that provides power bus ter mination and configuration settings Unless otherwise stated SAS is used in this server by...

Страница 11: ...the right side of the chassis and supports one low profile max length 6 6 PCI E x8 card The RSC R1UW 2E16 is located on the left side of the chassis and supports two full height half length PCI E x16...

Страница 12: ...N PHY1 RTL8201F x16 CPU1 PE3 x16 CPU1 PE2 DDR3 DIMM H G 2 1 DDR3 DIMM 2 1 P1 P0 PE3 PE2 DMI DMI PCH C602 C602J SPI SATA SCU USB USB LPC PEG0 PEG1 4 1 PEG1_8 PCI AT25321 BMC57810S 10G SFP Chipset SAS22...

Страница 13: ...e Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro...

Страница 14: ...1 6 SUPERSERVER 1027R 72RFTP User s Manual Notes...

Страница 15: ...e location for the rack unit that will hold the server It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are ge...

Страница 16: ...make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more si multaneously may cause the rack to become unstable Serve...

Страница 17: ...sible overloading of circuits might have on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable...

Страница 18: ...lso refer to the installation instructions that came with the rack unit you are using Identifying the Sections of the Rack Rails You should have received two rack rail assemblies in the rack mounting...

Страница 19: ...lize the chassis within the rack Installing the Inner Rails 1 Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes Make sure the e...

Страница 20: ...rter outer rail to the rear rack with three screws 5 Repeat steps 1 4 for the remaining outer rail Locking Tabs Both chassis rails have a locking tab which serves two functions The first is to lock th...

Страница 21: ...on the chassis with the front of the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides it may be necessary to depress the locking tabs when...

Страница 22: ...the two front brackets to each side of the chassis then the two rear brackets positioned with just enough space to accommodate the width of the telco rack Finish by sliding the chassis into the rack a...

Страница 23: ...rol Panel Buttons There are three push buttons located on the front of the chassis UID button a reset button and a power on off button UID Depressing the UID unit identifier button illuminates an LED...

Страница 24: ...may need to take Information LED This LED will be blue when the UID function has been activated When this LED flashes red it indicates a fan failure When red continuously it indicates an overheat con...

Страница 25: ...Carrier LEDs Green Each hard drive carrier has a green LED When illuminated this green LED indicates drive activity A connection to the SAS backplane enables this LED to blink on and off when that pa...

Страница 26: ...3 4 SUPERSERVER 1027R 72RFTP User s Manual Notes...

Страница 27: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 28: ...considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar...

Страница 29: ...l kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard proc...

Страница 30: ...ie en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de branch...

Страница 31: ...ert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuitos o sobrecorrientes de...

Страница 32: ...eift um Systemsbestandteile anzubringen oder zu entfernen Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing t...

Страница 33: ...nentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enle...

Страница 34: ...arnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o...

Страница 35: ...stallation in Bereichen mit beschr nktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m gli...

Страница 36: ...ame or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een...

Страница 37: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 38: ...para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour suppri...

Страница 39: ...ero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circulent sur le fond de panier Prendre des pr cautions lors de la maintenanc...

Страница 40: ...lectrical codes Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Bac...

Страница 41: ...ional laws and regulations Attention L quipement doit tre install conform ment aux normes lectriques nationales et locales Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lok...

Страница 42: ...seguir todas las leyes y reglamentos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vo...

Страница 43: ...dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilat...

Страница 44: ...Adapter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r alle an...

Страница 45: ...utres appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bi...

Страница 46: ...4 20 SUPERSERVER 1027R 72RFTP User s Manual Notes...

Страница 47: ...that the size and weight of the serverboard can cause it to bend if handled improperly which may result in damage To prevent the serverboard from bending keep one hand under the center of the board t...

Страница 48: ...only Make sure to install the serverboard into the chassis before you install the CPU heatsinks When receiving a serverboard without a processor pre installed make sure that the plastic CPU socket ca...

Страница 49: ...remove the WARNING plastic cap from the socket 5 Use your thumb and index finger to hold the CPU by its edges Align the CPU keys which are semi circle cutouts against the socket keys 6 Once they are a...

Страница 50: ...d plate again and double check that the CPU is aligned properly 7 With the CPU in the socket in spect the four corners of the CPU to make sure that they are flush with the socket 8 Close the load plat...

Страница 51: ...ink is loosened remove it from the CPU 5 Clean the surface of the CPU and the heatsink to get rid of the old thermal grease Reapply the proper amount of thermal grease before you re install the heatsi...

Страница 52: ...xt page Connecting Power Cables The X9DRW 7TPF has a 24 pin primary power supply connector designated JPW1 for connection to the ATX power supply Connect the appropriate connec tor from the power supp...

Страница 53: ...r Fail UID LED Power Fail LED Ground Ground 2 1 20 19 5 4 I O Ports The I O ports are color coded in conformance with the PC 99 specification See Figure 5 2 below for the colors and locations of the v...

Страница 54: ...vent inserting the DIMM module incorrectly see Figure 5 5 3 Gently press down on the DIMM module until it snaps into place in the slot Repeat for all modules Memory Support The X9DRW 7TPF supports up...

Страница 55: ...PU 2 DIMMs CPU1 P1 DIMMA1 P1 DIMMB1 1 CPU 4 DIMMs CPU1 P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 1 CPU 5 8 DIMMs CPU1 P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 Any memory pairs in P1 DIMMA2 P1 DIMMB2 P1 D...

Страница 56: ...ke sure you power off the system first Begin by removing the top chassis cover Two riser cards should be pre installed into the system Remove the screws that secure the riser cards to the rear of the...

Страница 57: ...TA3 S SATA0S SATA1 I SATA0 SXB2 SXB1_2 SXB1_1 SXB1_3 SFP1 SXB1D SXB1C SCU SGPIO1 T SGPIO2 T SGPIO1 COM1 USB0 1 SAS4 7 P2 DIMMF1 P2 DIMMF2 P1 DIMMA1 SXB1B SXB1A USB4 5 USB2 3 COM2 P1 DIMMD1 BATTERY P1...

Страница 58: ...4 pin External BMC I2 C Header for IPMI Card IPMI LAN Dedicated IPMI LAN I SATA 0 5 Intel SB SATA Connectors 0 5 JF1 Control Panel Header JL1 Chassis Intrusion JOH1 Overheat Fan Fail LED JPI2 C Power...

Страница 59: ...Chapter 5 Advanced Serverboard Setup 5 13 LED Description LED1 Power LED LED2 UID LED LED3 BMC Heartbeat LED LED4 SAS Activity LED LED5 SAS Heartbeat LED LED6 SAS Error LED LED7 UID LED...

Страница 60: ...connected to your power supply See the table on the right for pin definitions ATX Power 24 pin Connector Pin Definitions Pin Definition Pin Definition 13 3 3V 1 3 3V 14 12V 2 3 3V 15 COM 3 COM 16 PS_O...

Страница 61: ...lue LED by default Refer to the table on the right for pin definitions OH Fan Fail PWR Fail Blue_UID LED Pin Definitions JF1 Pin Definition 7 Red_LED Cathode OH Fan Fail Power Fail5 5V SB 8 Blue_UID L...

Страница 62: ...e Refer to the table on the right for pin definitions Reset Button Pin Definitions JF1 Pin Definition 3 Reset 4 Ground Power Button The Power Button connection is located on pins 1 and 2 of JF1 Mo men...

Страница 63: ...ed See the tables on the right for pin definitions FP USB 2 3 6 Pin Definitions USB 2 6 Pin Definition USB 3 Pin Definition 1 5V 1 5V 2 PO 2 PO 3 PO 3 PO 4 Ground 4 Ground 5 NC 5 Key NC No connection...

Страница 64: ...nagement via IPMI interface See the table on the right for pin definitions Fan Header Pin Definitions Pin Definition 1 Ground 2 12V 3 Tachometer 4 Pulse Width Modu lation PWM Chassis Intrusion A Chass...

Страница 65: ...ATA 0 3 connections See the table on the right for pin definitions Note NC No Connection T SGPIO S SGPIO Pin Definitions Pin Definition Pin Definition 1 NC 2 NC 3 Ground 4 Data 5 Load 6 Ground 7 Clock...

Страница 66: ...gabit small form factor pluggable SFP transceivers optimized for on board telecommunication and data communications In addition to LAN TLAN ports an IPMI_Dedicated LAN located above USB 0 1 ports on t...

Страница 67: ..._CLK4 14 SMB_DAT4 15 3V_DUAL 16 SERIRQ 17 GND 18 CLKRUN X 19 LPCPD 20 LDRQ X Front Panel LEDs for TLAN1 TLAN2 The Front Panel LED indicator for TLAN port 1 is located on pins 3 and 4 of JF2 and for TL...

Страница 68: ...ear CMOS and will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS 1 First power down the system and un...

Страница 69: ...angs See the table on the right for jumper settings Watch Dog must also be enabled in the BIOS Watch Dog Jumper Settings Jumper Setting Definition Pins 1 2 Reset default Pins 2 3 NMI Open Disabled BMC...

Страница 70: ...setting is to close 2 3 for normal operation See the table on the right for jumper settings Flash Descriptor Security Overwrite Jumper Settings Jumper Setting Definition 1 2 Enabled 2 3 Normal Defaul...

Страница 71: ...n nections ME Mode Select Jumper Settings Jumper Setting Definition Pins 1 2 Manufacture Mode Pins 2 3 Normal Default Manufacture Mode Jumper JPME1 allows the user to flash the system firmware from a...

Страница 72: ...g the power cord before removing or installing components See the tables at right for more information Onboard PWR LED Indicator LE1 LED Settings LED Color Status Off System Off PWR cable not connecte...

Страница 73: ...aster than the connec tions of Parallel ATA In addition I SATA5 also functions as a wireless SATA DOM that can be used to provide power supply to onboard SATA DOM devices See the table on the right fo...

Страница 74: ...ebsite at http www supermicro com products Find the product page for your motherboard here where you may down load individual drivers and utilities After creating a CD DVD with the ISO files insert th...

Страница 75: ...mperature system voltages and fan status See the figures below for examples of the SuperDoctor III interface Note The default User Name and Password for SuperDoctor III is ADMIN ADMIN Note When SuperD...

Страница 76: ...User s Manual can be downloaded from the Supermicro web site at http www supermicro com products accessories soft ware SuperDoctorIII cfm For Linux we recommend that you use the SuperDoctor II applica...

Страница 77: ...tly followed Figure 5 5 Installing the Onboard Battery LITHIUM BATTERY BATTERY HOLDER BATTERY HOLDER LITHIUM BATTERY OR Please handle used batteries carefully Do not damage the battery in any way a da...

Страница 78: ...5 32 SUPERSERVER 1027R 72RFTP User s Manual Notes...

Страница 79: ...t damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a gr...

Страница 80: ...ol panel buttons Details on JF1 can be found in Chapter 5 Advanced Serverboard Setup 6 3 System Fans The 1027R 72RFTP contains six counter rotating fans Each fan unit is actually made up of two fans j...

Страница 81: ...direc tion as the arrows on the other fans 4 Connect the fan wires to the fan headers on the serverboard 5 Power up the system and check that the fan is working properly before re placing the chassis...

Страница 82: ...ews to set up Air Shroud Installation 1 Disconnect the chassis from any power souce 2 Lower the air baffle MCP 310 19013 0B into place in between the third and fourth system fans seperating the CPU an...

Страница 83: ...Chapter 6 Advanced Chassis Setup 6 5 Figure 6 4 Air Shroud Installation Screw Notch Figure 6 3 Air Baffle Installation Air Baffle...

Страница 84: ...alling removing a DVD ROM drive you will need to gain access to the inside of the server by removing the top cover of the chassis Proceed to the DVD ROM Drive Installation section later in this chapte...

Страница 85: ...rives installed must remain in the chassis Removing Hard Drive Carrier from the Chassis 1 Press the release button on the drive carrier This extends the drive carrier handle 2 Use the handle to pull t...

Страница 86: ...of the carrier 3 Align the drive in the carrier so that the screw holes of both line up Note that there are holes in the carrier marked SAS to aid in correct installation 4 Secure the drive to the ca...

Страница 87: ...y remove the server from the rack 2 Remove the chassis cover 3 Unplug the drive s power and data cables from the serverboard and or back plane 4 Unlock the mini bezel lock scew and remove the mini bez...

Страница 88: ...on until the failed unit has been replaced Replace ment units can be ordered directly from Supermicro The power supply units have a hot swap capability meaning you can replace the failed unit without...

Страница 89: ...Chapter 6 Advanced Chassis Setup 6 11 Figure 6 7 Removing Replacing the Power Supply...

Страница 90: ...6 12 SUPERSERVER 1027R 72RFTP User s Manual Notes...

Страница 91: ...he options that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved...

Страница 92: ...n access the other setup screens An AMI BIOS identification string is displayed at the left bottom corner of the screen below the copyright message Warning Do not upgrade the BIOS unless your system h...

Страница 93: ...The date must be entered in Day MM DD YY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 Supermicro X9DRW 7 iTPF Version...

Страница 94: ...POST messages The op tions are Enabled and Disabled AddOn ROM Display Mode Use this item to set the display mode for the Option ROM Select Keep Current to use the current AddOn ROM Display setting Sel...

Страница 95: ...than five minutes The options are Enabled and Disabled Power Button Function If this feature is set to Instant Off the system will power off immediately as soon as the user presses the power button If...

Страница 96: ...n Socket 1 or Socket 2 supports 64 bit technology Clock Spread Spectrum Select Enable to enable Clock Spectrum support which will allow the BIOS to moni tor and attempt to reduce the level of Electrom...

Страница 97: ...o use the Intel Advanced Encryption Standard AES New Instruc tions NI to ensure data security The options are Enabled and Disabled MLC Streamer Prefetcher Available when supported by the CPU If set to...

Страница 98: ...sable power saving settings The options are Disabled Energy Efficient and Custom If the option is set to Custom the following items will display EIST Available when Power Technology is set to Custom E...

Страница 99: ...um system performance with maximum cooling or maximum energy efficiency with maxi mum power saving The fan speeds are controlled by the firmware management via IPMI 2 0 The options are Performance Bal...

Страница 100: ...feature offers fully protected I O resource sharing across Intel platforms providing greater reliability security and availability in networking and data sharing The options are Enabled and Disabled...

Страница 101: ...tions are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto IIO 2 PCIe Port Bifurcation Control This submenu configures the following IO PCIe Port Bifurcation Control settings for IIO 2 PCIe ports to determine...

Страница 102: ...connections The options are Slow and Fast QPI Link Frequency Select Use this feature to select the desired QPI frequency The options are Auto 6 4 GT s 7 2 GT s and 8 0 GT s DIMM Configuration This sec...

Страница 103: ...y saving The options are Performance and Energy Saving DDR Speed Use this feature to force a DDR3 memory module to run at a frequency other than what is specified in the specification The options are...

Страница 104: ...rottling improves reliability and reduces power consumption in the proces sor via automatic voltage control during processor idle states The options are Disabled and CLTT Closed Loop Thermal Throttlin...

Страница 105: ...e EHCI hand off When enabled EHCI ownership change will be claimed by the EHCI driver The options are Disabled and Enabled SATA Configuration When this submenu is selected the AMI BIOS automatically d...

Страница 106: ...Spin up support to prevent excessive power consumption caused by multiple HDDs spinning up simultaneously The options are Enabled and Disabled RAID Mode The following items are displayed when RAID Mo...

Страница 107: ...automatically set the maximum payload value for a PCI E device to enhance system performance The options are Auto 128 Bytes and 256 Bytes Maximum Read Request Select Auto to allow the system BIOS to...

Страница 108: ...sabled Load Onboard SAS Option ROM Select Enabled to use the onboard SAS Option ROM to boot the computer using a SAS device The options are Enabled and Disabled VGA Priority This feature allows the us...

Страница 109: ...is feature to select the desired mode for a serial port specified The options are Normal and High Speed Serial Port 2 Configuration SOL Serial Port Select Enabled to enable serial port 2 The options a...

Страница 110: ...00 to use the ASCII Character set Select VT100 to add color and function key support Select ANSI to use the Extended ASCII Char acter Set Select VT UTF8 to use UTF8 encoding to map Unicode characters...

Страница 111: ...support for ANSI VT100 terminals The options are Enabled and Disabled Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server The optio...

Страница 112: ...ation type for Con sole Redirection Select VT100 to use the ASCII character set Select VT100 to add color and function key support Select ANSI to use the extended ASCII character set Select VT UTF8 to...

Страница 113: ...nabled and Disabled High Precision Event Timer Select Enabled to activate the High Precision Event Timer HPET that produces periodic interrupts at a much higher frequency than a Real time Clock RTC do...

Страница 114: ...ve Status This item displays the status of TPM Support to indicate if TPM is currently ac tive or deactivated TPM Owner Status This item displays the status of TPM Ownership Intel TXT LT SX Configurat...

Страница 115: ...tate Trusted Platform state ME Subsystem This feature displays the following ME Subsystem Configuration settings ME BIOS Interface Version ME Version iSCSI Configuration This item displays iSCSI confi...

Страница 116: ...AutoNeg 10Mbps Half 10Mbps Full 100Mbps Half and 100Mbps full Wake on LAN Select enabled to wake the system with a magic packet The options are En abled and Disabled Blink LEDs This feature allows the...

Страница 117: ...em Management BIOS Event Logging during system boot The options are Enabled and Disabled Runtime Error Logging Support Select Enabled to support Runtime Error Logging The options are Enabled and Disab...

Страница 118: ...ons are Do Nothing and Erase Immediately SMBIOS Event Log Standard Settings Log System Boot Event Select Enabled to log system boot events The options are Disabled and Enabled MECI Multiple Event Coun...

Страница 119: ...stalled in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings Erase SEL...

Страница 120: ...effect when the system is rebooted The options are No and Yes Configuration Address Source This feature allows the user to select the source of the IP address for this computer If Static is selected y...

Страница 121: ...ce etc Use these items to specify the sequence of boot device priority Delete Boot Option This feature allows the user to select a boot device to delete from the boot priority list Delete Boot Option...

Страница 122: ...n a password entry is required Select Setup to require the password only when entering setup Select Always to require the pass word when entering setup and on each boot The options are Setup and Alway...

Страница 123: ...Reset When you have completed the system configuration changes select this option to save the changes and reboot the computer so that the new system configuration settings can take effect Select Save...

Страница 124: ...faults Select this feature and press Enter to save the current settings as the user s defaults When the dialog box appears asking you if you want to save values as user s defaults select Yes to save t...

Страница 125: ...eries of audible beeps The numbers on the fatal error list correspond to the number of beeps for the corresponding error BIOS Error Beep Codes Beep Code LED Error Message Description 1 beep Refresh Ci...

Страница 126: ...A 2 SUPERSERVER 1027R 72RFTP User s Manual Notes...

Страница 127: ...00 SDRAM or 128 GB of ECC UDIMM type memory See the memory section in Chapter 5 for details SAS Controller LSI 2208 SAS2 controller with 1GB cache for up to sixteen port SAS2 which supports hardware R...

Страница 128: ...Input Frequency 50 to 60 Hz Power Supply Rated Output Power 700W Part PWS 703P 1R Rated Output Voltages 12V 58A 5Vsb 3A Operating Environment Operating Temperature 10 to 35 C 50 to 95 F Non operating...

Страница 129: ...nd Canada CE Marking Europe California Best Management Practices Regulations for Perchlorate Materials This Perchlorate warning applies only to products containing CR Manganese Dioxide Lithium coin ce...

Страница 130: ...erform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such...