D-10
SC815 Chassis Manual
Select the
2.
Hardware
tab and select
Device Manager
to bring up the list of
system devices.
You may see one or two yellow question marks (?) that read QLogic GEM354
3.
or GEM318 SCSI Processor Device. Right click on these, and select
uninstall
. If both devices have question marks, uninstall both.
Select the
4.
Action
tab and select
Scan for Hardware Changes
. The Hard-
ware Wizard program should start up. Click
Next
.
At the first prompt, select
5.
Display a list of known device drivers for the
device so that I can choose a specific driver
and click
Next
.
Select
6.
Other Devices
and click
Next
.
Select
7.
Have Disk
, and specify the
floppy drive location
in the options box.
Then click
Next
Select
8.
Enclosure Services Device
and click
Next
.
Ignore the warning prompt by clicking
9.
Yes
.