Installing a Passive CPU Heatsink
1. Do not apply any thermal grease to the heatsink or the CPU die -- the
required amount has already been applied.
2. Place the heatsink on top of the CPU so that the four mounting holes
are aligned with those on the Motherboard's and the Heatsink Bracket
underneath.
3. Screw in two diagonal screws (i.e., the #1 and the #2 screws) until just snug
(-do not over-tighten the screws to avoid possible damage to the CPU.)
4. Finish the installation by fully tightening all four screws.
OPEN 1st
Motherboard
Screw#1
Screw#2
Mounting Holes
Screw#3
Screw#4
Direction
of Airfl ow
Note:
Make sure the heatsink is placed so that the fi ns of the heatsink are in the
direction of the airfl ow in your system.