UPER CSE-M34S/CSE-M34T User's Guide

8

5.  SCSI (Super) GEM Driver Installation Instructions for
Windows OS

Please refer to the following instructions to install  the SCSI GEM

Driver for the Windows OS systems.

(*Note: 

This driver is not necessary for other Operating Systems. 

 

If you

have two SCA backplanes, you will need to install the driver twice.)

The driver is located on the Super Micro motherboard driver CD or is available
for download from our FTP site: 

ftp://ftp.supermicro.com/driver/Qlogic/

Follow the procedure below to install this driver to your system.

Installing  the driver:

1) Right click on “My Computer” and choose “Property”.
2) Select “Hardware” tab and click on “Device Manager”.
3) Open “Other Devices” or wherever “GEM318” is on.
4) Right click on this device and choose “Property”.
5) Click on “Driver” tab and choose “Update Driver”.
6) Click “Next” 2 times, uncheck both “Floppy disk drives” and “CD-ROM
drives”.  Then, select the item- “Specify a location,” and choose “Next”.
7) Click on “Browse” and choose D drive or wherever Supermicro Setup CD
is in.
8) Choose “Qlogic” folder and click on “Open”.
9) System will automatically detect GEM318 and install the drive from this

point on.

or,

1) Right click the "My Computer" icon on your desktop and choose Proper-
ties.
2) Click on the Hardware tab and click on "Device Manager" to bring up the
list of system devices.
3) You may see one or two yellow question marks (?) that read QLogic
GEM354 or GEM318 SCSI Processor Device.  Right click on these, and
choose to uninstall.  If two such question marks are present, uninstall both.
4)  Click on Action tab and choose "Scan for Hardware Changes".  The
Hardware Wizard program should start up.  Click "Next".
5) At the first prompt, choose “Display a list of known device drivers for the
device so that I can choose a specific driver” and click "Next".
6) Choose “Other Devices” and click Next.
7) Choose “Have Disk”,  and specify your floppy drive location in the options
box. Then,  click "Next".
8) Highlight “Enclosure Services Device” and click "Next".
9) Ignore the warning prompt by clicking "Yes".

Содержание CSE-M34S

Страница 1: ...Rev 1 0 SUPER USER S GUIDE Mobile Rack CSE M34S CSE M34T ...

Страница 2: ...S CSE M34T User s Guide 2 Table of Contents 1 Packaging List 3 2 Technical Specifications 3 3 Jumper Settings 4 4 Hardware Installation Procedures 6 5 SCSI Super GEM Drive Installation Instructions for Windows OS 8 ...

Страница 3: ...d screws Eight 8 counts of M3 washer head screws Eighteen 18 counts of Pan head screws Drive Carrier Four 4 CSE PT10 beige only For CSE M34T only Serial ATA Backplane CSESATA M34 Four 4 Serial ATA Cables CBL 0044 Serial ATA LED cable CBL 0057 Packing List SCSI cable CBL 027 U320 SCSI Backplane CSESCA 002 For CSE M34S only 2 Technical Specifications Chassis supported SC762 SC830 SC942 Occupancy Thr...

Страница 4: ...25 Jumper Description Setting JP14 Delay Start Closed Enable Open Disable Default JP18 Buzzer Reset Closed Enable Open Disable Default JP25 Overheat Temperature Open 50o C 1 2 55o C Default 2 3 60o C JP21 SCSI Termination Closed Enable Default Open Disable JP24 SCSI ID Selection 1 2 SCSI IDs 0 1 2 3 4 Default 2 3 SCSI IDs 9 10 11 12 13 ...

Страница 5: ...emperature Open 45O C 1 2 50O C Default 2 3 55O C JP28 Fan Sense 1 2 Enabled if a fan is not present the alarm will sound Default 2 3 Disabled JP26 Common Act 1 Act 4 Connect this header to CBL 0057 SATA LED Cable JP27 Common Act In Act 1 Closed Enable Open Disable Default JP29 Common Act In Act 2 Closed Enable Open Disable Default JP30 Common Act In Act 3 Closed Enable Open Disable Default JP31 C...

Страница 6: ...are assigned automatically by the backplane Do not set IDs manually on the drives See the previous section for SCSI ID jumper settings 2 SCSI termination is enabled by default on the SCSI backplane Push the release button Pull up the handle 2 Pull out drive trays as shown below on the right 3 Mount a drive in a carrier and secure it with screws as shown below Mount a drive into a carrier Secure th...

Страница 7: ...s the backplane 2 Pull out the rear fan bracket as shown below The CSE M34T SATA Model The CSE M34S SCSI Model Pull out the rear fan bracket B Accessing the Drive Backplane 1 Remove the two screws as shown below The CSE M34T SATA Model The CSE M34S SCSI Model Remove the screws Installation Procedures ...

Страница 8: ...t the item Specify a location and choose Next 7 Click on Browse and choose D drive or wherever Supermicro Setup CD is in 8 Choose Qlogic folder and click on Open 9 System will automatically detect GEM318 and install the drive from this point on or 1 Right click the My Computer icon on your desktop and choose Proper ties 2 Click on the Hardware tab and click on Device Manager to bring up the list o...

Отзывы: