4-34
Supermicro C9X299-PG/-PGF/-RPGF Motherboard User’s Manual
PS Current Threshold3
The PS Current Threshold2 is defined in 1/4A (Amperes) increments
and uses the BIOS mailbox command 0x3. A value of 400 equals
100A. Range is 0-512 which translates to 0-128A. Enter 0 for AUTO.
Default is 4 for 1A.
PS3 Enable
Enable or Disables PS3. Uses BIOS VR mailbox command line 0x3.
The options are
Enabled
or Disabled.
PS4 Enable
Enable or Disables PS4. Uses BIOS VR mailbox command line 0x3.
The options are
Enabled
or Disabled.
IMON Slope
IMON (Load Current Monitor) Slope is defined in 1/100 increments
and uses the BIOS VR mailbox command 0x4. Range is 0-200. For
example, enter 125 for a 1.25 slope. Enter
0
for AUTO.
IMON Offset
IMON Offset is defined in 1/1000 increments and uses the BIOS
VR mailbox command 0x4. For example, enter 25,348 for a 25.348
offset. Range is 0-63999. The default is
0
.
IMON Prefix
This feature sets the IMON offset value to a positive or negative
number. The options are
+(Default)
or -.
VR Current Limit
This feature sets the Voltage Regulator current limit. The value
represents the maximum instantaneous current allowed at any
given time. The value is represented in 1/4A (Ampere) increments.
A value of 400 equals 100A. Set this number to
0
for Auto. This
uses the BIOS VR mailbox command 0x6.
VR Voltage Limit
This feature sets the Voltage Regulator voltage limit. The value is
represented in mV. A value of 1250 equals 1.25V. Set this number
to
0
for Auto. This uses the BIOS VR mailbox command 0x6.
Содержание C9X299-PG
Страница 1: ...C9X299 PG C9X299 PGF C9X299 RPGF USER S MANUAL Revision 1 0...
Страница 14: ...xiv Notes Supermicro C9X299 PG PGF RPGF Motherboard User s Manual...
Страница 66: ...Chapter 2 Installation 2 39 Notes...
Страница 147: ...A 2 Supermicro C9X299 PG PGF RPGF Motherboard User s Manual Notes...
Страница 153: ...C 4 Supermicro C9X299 PG PGF RPGF Motherboard User s Manual Notes...