Chapter 3: System Interface
3-3
•
NIC: Indicates network activity on either LAN1 or LAN2 when flashing.
Informational LED
Status
Description
Continuously on and red
An overheat condition has occured.
(This may be caused by cable congestion.)
Blinking red (1Hz)
Fan failure, check for an inoperative fan.
Blinking red (0.25Hz)
Power failure, check for a non-operational power supply.
Solid blue
Local UID has been activated. Use this function to locate
the server in a rack mount environment.
Blinking blue (300 mSEC) Remote UID is on. Use this function to identify the
server from a remote location.
•
Information LED
: Alerts operator of several states, as noted in the table below.
3-3 Control Panel LEDs
The four control panels are located on the front handle of the SC827 chassis. Each
control panel has two LEDs. These LEDs provide you with critical information related
to different parts of the system. This section explains what each LED indicates when
illuminated and any corrective action you may need to take.
Содержание 2022TG-H6IBQRF
Страница 1: ...A SERVER 2022TG H6IBQRF 2022TG H6RF SUPER USER S MANUAL Revision 1 0c ...
Страница 16: ...1 8 A SERVER 2022TG H6IBQRF H6RF USER S MANUAL Notes ...
Страница 26: ...2 10 A SERVER 2022TG H6IBQRF H6RF USER S MANUAL Notes ...
Страница 50: ...4 20 A SERVER 2022TG H6IBQRF H6RF USER S MANUAL Notes ...
Страница 97: ...Chapter 6 Advanced Chassis Setup 6 21 Release Tab Figure 6 20 Changing the Power Supply ...
Страница 98: ...6 22 A SERVER 2022TG H6IBQRF H6RF USER S MANUAL Notes ...
Страница 118: ...A 2 A SERVER 2022TG H6IBQRF H6RF USER S MANUAL Notes ...