Console Redirection
Access the submenu to make changes to the following settings.
COM Port Address
This item allows you to specify which COM port to direct Console to:
Onboard COM A or Onboard COM B. This setting can also be Disabled.
BAUD Rate
This item allows you to set the BAUD rate for console redirection. The
options are 300, 1200, 2400, 9600, 19.2K, 38.4K, 57.6K, and 115.2K.
Console Type
This item allows you to select the console type for console redirection.
The options are VT100, VT100,8bit, PC-ANSI, 7bit, PC ANSI, VT100+,
and VT-UTF8.
Flow Control
This item allows you to choose select the flow control type for console
redirection. The options are: None, XON/XOFF, and CTS/RTS.
Console Connection
This item allows you to decide how you want console redirection to be
connected: either Direct or Via Modem.
Continue CR after POST
This item allows you to decide if you want to continue with console
redirection after the POST routine. The options are On and Off.