Chapter 2: Installation
Power Fail LED
The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table below
for pin definitions.
Power Fail LED
Pin Definitions (JF1)
Pin# Definition
5
3.3V
6
PWR Supply Fail
1. Power Fail LED
2. Information LED
Power Button
UID LED
NIC1 Active LED
Reset Button
HDD LED
PWR LED
Reset
PWR
3.3V Stby
3.3V Stby
Ground
19
X
Ground
X
3.3V Stby
20
1
2
Ground
Power Fail LED
NIC2 Active LED
NMI
3.3V
OH/Fan Fail/PWR Fail LED
3.3V Stby
1
2
Information LED-UID/OH/PWR Fail/Fan Fail LED
Pin Definitions (Pin 7 & Pin 8 of JF1)
Status
Description
Solid red
An overheat condition has occurred. (This may be caused by cable congestion).
Blinking red (1Hz)
Fan failure: check for an inoperative fan.
Blinking red (0.25Hz)
Power failure: check for a non-operational power supply
Solid blue
Local UID is activated. Use this function to locate a unit in a rack mount
environment that might be in need of service.
Blinking blue (300 msec)
Remote UID is on. Use this function to identify a unit from a remote location that
might be in need of service.
Information LED (OH/Fan Fail/PWR Fail/UID LED)
The Information LED (OH/Fan Fail/PWR Fail/UID LED) connection is located on pins 7 and
8 of JF1. The LED on pin 7 is active when the UID switch on the rear I/O panel is pressed.
The LED on pin 8 provides warnings of overheat, power failure, or fan failure. Refer to the
tables below for more information.