background image

USER'S MANUAL 

Revision 1.0b

X12DAi-N6

Содержание X12DAi-N6

Страница 1: ...USER S MANUAL Revision 1 0b X12DAi N6...

Страница 2: ...ed in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause har...

Страница 3: ...address the needs of next generation workstation applications Please note that this motherboard is intended to be installed and serviced by professional technicians only For processor memory updates p...

Страница 4: ...puter B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma...

Страница 5: ...22 2 3 Motherboard Installation 40 2 4 Memory Support and Installation 42 2 5 Rear I O Ports 47 2 6 Front Control Panel 52 2 7 Connectors 58 2 8 Jumper Settings 70 2 9 LED Indicators 73 Chapter 3 Tro...

Страница 6: ...S POST Codes A 1 BIOS POST Codes 159 Appendix B Software B 1 Microsoft Windows OS Installation 160 B 2 Driver Installation 162 B 3 SuperDoctor 5 163 B 4 BMC 164 B 5 Logging into the BMC Baseboard Mana...

Страница 7: ...data from storage devices can be found at our website https www supermicro com about policies disclaimer cfm url wdl utility Lot9_Secure_Data_Deletion_Utility Firmware related and AOC user s guides h...

Страница 8: ...erboard Image Note All graphics shown in this manual were based upon the latest PCB revision available at the time of publication of the manual The motherboard you received may or may not look exactly...

Страница 9: ...AN6 FAN3 FAN4 FAN7 JNCSI JNVME1 JNVME2 JPCIE5 JPCIE4 JPCIE3 JPCIE2 JPCIE1 JF1 JUSBA JSD1 JSD2 JUSB1 JP7 JUSB31_I1 JLAN1 JPCIE6 JAUDIO1 JIPMB1 RAID KEY 1 I SATA5 I SATA4 I SATA3 I SATA2 I SATA1 I SATA0...

Страница 10: ...OT1 PCI E 4 0 X16 CPU2 SLOT2 PCI E 4 0 X16 CPU1 SLOT3 PCI E 4 0 X16 CPU2 SLOT4 PCI E 4 0 X16 CPU1 SLOT5 PCI E 4 0 X16 CPU2 SLOT6 PCI E 4 0 X8 PCH Notes See Chapter 2 for detailed information on jumper...

Страница 11: ...er supported by the Intel PCH J37 USB5 6 Front accessible USB 3 0 header with support for two USB 3 0 ports JAUDIO1 Audio port on the I O back panel JD1 Speaker buzzer header use in conjunction with a...

Страница 12: ...USB31_l1 USB7 Front accessible USB 3 2 Gen 2x1 Type C port at 10Gbps JVGA VGA port on the I O back panel JVRM1 VRM SMB clock to BMC JVRM2 VRM SMB data to BMC JSD1 JSD2 SATA DOM Disk on Module power co...

Страница 13: ...IMM Size Up to 256GB at 1 2V Note For the latest CPU memory updates please refer to our website at http www supermicro com products motherboard Chipset Intel PCH C621A Expansion Slots One PCIe 4 0 x8...

Страница 14: ...T 5V stdby 3 3V stdby 1 8V PCH 1 05V PCH 1 0V PCH CPU temperature VRM temperature PCH temperature and system temperature 7 1 CPU switch phase voltage regulator CPU thermal trip support Platform Enviro...

Страница 15: ...d heatsink cooling restrictions For proper thermal management please check the chas sis and heatsink specifications for proper CPU TDP sizing Note 2 For BMC configuration instructions please refer to...

Страница 16: ...2 C1 BMC PCIe X8 G4 CPU2 F1 SPI CPU1 CPU2 A1 UPI SPI 2666 2933 3200 7 1 PHASE 270W PCIe GEN4 X16 0 PECI 30 BT SOCKET ID 0 SOCKET ID 1 PCIe X16 G4 CPU2 D1 2666 2933 3200 CPU2 H1 AST2600 BXNBPO traQMO P...

Страница 17: ...With the support of the new Intel Microarchitecture the X12DAi N6 dramatically increases system performance for a multitude of workstation applications Features supported Performance improvements with...

Страница 18: ...oltage monitor Fan Status Monitor with Firmware Control The system health monitor embedded in the BMC chip can check the RPM status of the cooling fans The CPU and chassis fans are controlled via lPMI...

Страница 19: ...t for processors that have high CPU clock rates where noisy power transmission is present The X12DAi N6 motherboard accommodates a 24 pin ATX power supply Although most power supplies generally meet t...

Страница 20: ...ane PMem offers higher capacities than the traditional DDR4 modules It also provides increased storage capabilities due to data persistence in a DDR4 form factor for higher performance computing platf...

Страница 21: ...only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the motherboard and peripherals back into their antistati...

Страница 22: ...the AC power cords from all power supplies after shutting down the system Check that the plastic protective cover is on the CPU socket and none of the socket pins are bent If they are contact your re...

Страница 23: ...23 Chapter 2 Installation Cutout CPU Key Pin 1 Processor Top View 1 The 3rd Gen Intel Xeon Scalable Processor...

Страница 24: ...24 Super X12DAi N6 User s Manual 2 The Processor Carrier Cutout CPU Key Pin 1 Carrier Bottom View Carrier Top View...

Страница 25: ...atsink Note Exercise extreme care when handling the heatsink Pay attention to the edges of heatsink fins which can be sharp To avoid damaging the heatsink please do not apply excessive force on the fi...

Страница 26: ...26 Super X12DAi N6 User s Manual Overview of the CPU Socket The CPU socket is protected by a plastic protective cover Plastic Protective Cover CPU Socket...

Страница 27: ...carrier Carefully follow the instructions given in the installation section to place a processor into the carrier to create a processor carrier 1 The 3rd Gen Intel Xeon Scalable Processor Intel Proces...

Страница 28: ...ocessor Heatsink Module The Processor Heatsink Module PHM contains a heatsink a processor carrier and the 3rd Gen Intel Xeon Scalable Processor 1 Heatsink 2 Processor Carrier 3 The 3rd Gen Intel Xeon...

Страница 29: ...h Gold CPU contacts facing down Locate the small gold triangle at the corner of the processor and the corresponding hollowed triangle on the processor carrier as shown in the graphics below Please not...

Страница 30: ...on the processor against the CPU keys on the carrier a and b as shown in the drawing below 5 Once they are properly aligned carefully place one end of the processor into the latch marked 1 on the carr...

Страница 31: ...After the processor is placed inside the carrier examine the four sides of the processor making sure that the processor is properly seated on the carrier Processor Carrier Assembly Top View Processor...

Страница 32: ...iangle on the CPU and the triangle on the carrier Triangle indicates Pin 1 3 Using Pin 1 as a guide turn the processor carrier assembly over with the gold contacts facing up Locate Pin 1 A on the proc...

Страница 33: ...rd comes with a plastic protective cover installed on the CPU socket Remove it from the socket to install the Processor Heatsink Module PHM Gently pull up one corner of the plastic protective cover to...

Страница 34: ...Rotating Wire A B C D Peek Nut 1 2 3 4 Rotating Wire a b c d Threaded Fastener Rotating Wire 3 Peek Nut A B C D Rotating Wire 1 2 Rotating Wire 4 Threaded Fastener a b c d a b c d Threaded Fasteners...

Страница 35: ...corresponding threaded fasteners on the CPU socket 2 Once they are aligned gently place the heatsink on top of the CPU socket making sure that each peek nut is properly attached to its corresponding...

Страница 36: ...ghten all peek nuts in the sequence of A B C and D with even pressure To avoid damaging the processor or socket do not use a force greater than 12 lbf in when tightening the screws 5 Examine all corne...

Страница 37: ...g down the system Then follow the steps below 1 Use a T30 bit screwdriver to loosen the four peek nuts on the heatsink in the sequence of A B C and D A B C D Peek Nut Side View Top View Unlatched Stat...

Страница 38: ...lease follow the steps below 1 Detach four plastic clips marked a b c and d on the processor carrier assembly from the four corners of heatsink marked A B C and D in the drawings below c a b d A C D B...

Страница 39: ...ocessor with care Removing the Processor from the Processor Carrier Assembly Once you have removed the processor carrier assembly from the PHM you are ready to remove the processor from the processor...

Страница 40: ...ME1 P2 DIMMF1 P2 DIMMH1 CPU2 CPU1 CPU1 SLOT1 PCI E 4 0 X16 CPU2 SLOT2 PCI E 4 0 X16 CPU1 SLOT3 PCI E 4 0 X16 CPU2 SLOT4 PCI E 4 0 X16 CPU1 SLOT5 PCI E 4 0 X16 CPU2 SLOT6 PCI E 4 0 X8 PCH 2 3 Motherboa...

Страница 41: ...4 Install standoffs in the chassis as needed 5 Install the motherboard into the chassis carefully to avoid damaging other motherboard components 6 Using the Phillips screwdriver insert a pan head 6 s...

Страница 42: ...Support for the 3rd Gen Intel Xeon Scalable Processors DDR4 Memory Support for the 3rd Gen Intel Xeon Scalable Processors Type Ranks Per DIMM Data Width DIMM Capacity GB Speed MT s Voltage V Slots Per...

Страница 43: ...1 P1 DIMMG1 CPU2 P2 DIMMA1 P2 DIMME1 2 CPUs 8 DIMMs Note CPU1 P1 DIMMA1 P1 DIMME1 P1 DIMMC1 P1 DIMMG1 CPU2 P2 DIMMA1 P2 DIMME1 P2 DIMMC1 P2 DIMMG1 2 CPUs 10 DIMMs CPU1 P1 DIMMA1 P1 DIMME1 P1 DIMMC1 P1...

Страница 44: ...on Matrix DDR4 DIMMS with PMem 200 Series DIMM Type Ranks Per DIMM Data Width Stack DIMM Capacity GB DRAM Density 8Gb 16Gb RDIMM up to 3200 1Rx8 N A N A 1Rx4 16GB 32GB 1Rx8 16GB 32GB 1Rx4 32GB 64GB RD...

Страница 45: ...N1 JPCIE6 JAUDIO1 JIPMB1 RAID KEY 1 I SATA5 I SATA4 I SATA3 I SATA2 I SATA1 I SATA0 I SATA6 I SATA7 LAN 1 2 HD AUDIO P2_NVME0 1 USB7 3 1 LED PWR USB4 3 1 P1_NVME0 1 USB5 6 3 0 USB0 1 2 3 3 0 VGA COM1...

Страница 46: ...he memory slot Warning Please do not use excessive force when pressing the release tabs on the ends of the DIMM socket to avoid causing any damage to the DIMM module or the DIMM socket Please handle D...

Страница 47: ...JNVI2C JPME1 JPL1 JWD1 JPL2 JD1 JVRM1 JVRM2 JL1 JSPDIF_IN1 JSPDIF_OUT1 JTPM1 JA1 JRK1 LEDM1 LE4 LE7 JPI2C1 JVGA FAN1 FAN2 FAN5 FAN6 FAN3 FAN4 FAN7 JNCSI JNVME1 JNVME2 JPCIE5 JPCIE4 JPCIE3 JPCIE2 JPCIE...

Страница 48: ...1 P1 DIMMC1 P1 DIMMG1 P1 DIMMF1 P1 DIMME1 P1 DIMMH1 P2 DIMMG1 P2 DIMMC1 P2 DIMMD1 P2 DIMMB1 P2 DIMMA1 P2 DIMME1 P2 DIMMF1 P2 DIMMH1 CPU2 CPU1 CPU1 SLOT1 PCI E 4 0 X16 CPU2 SLOT2 PCI E 4 0 X16 CPU1 SLO...

Страница 49: ...ATA0 I SATA6 I SATA7 LAN 1 2 HD AUDIO P2_NVME0 1 USB7 3 1 LED PWR USB4 3 1 P1_NVME0 1 USB5 6 3 0 USB0 1 2 3 3 0 VGA COM1 CMOS CLEAR TPM PORT80 JTPM1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMMC1 P1 DIMMG1 P...

Страница 50: ...6 3 0 USB0 1 2 3 3 0 VGA COM1 CMOS CLEAR TPM PORT80 JTPM1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMMC1 P1 DIMMG1 P1 DIMMF1 P1 DIMME1 P1 DIMMH1 P2 DIMMG1 P2 DIMMC1 P2 DIMMD1 P2 DIMMB1 P2 DIMMA1 P2 DIMME1 P2...

Страница 51: ...USB0 2 USB1 3 USB2 4 USB3 5 USB4 6 USB5 USB6 7 USB7 BAR CODE DESIGNED IN USA MAC CODE X12DAi N REV 1 01 BIOS LICENSE JM2_2 MH18 MH17 JM2_1 MH16 MH15 HEARTBEAT BMC FANA JBT1 T SGPIO2 T SGPIO1 BT1 JPWR3...

Страница 52: ...1 P1 DIMMA1 P1 DIMMD1 P1 DIMMC1 P1 DIMMG1 P1 DIMMF1 P1 DIMME1 P1 DIMMH1 P2 DIMMG1 P2 DIMMC1 P2 DIMMD1 P2 DIMMB1 P2 DIMMA1 P2 DIMME1 P2 DIMMF1 P2 DIMMH1 CPU2 CPU1 CPU1 SLOT1 PCI E 4 0 X16 CPU2 SLOT2 PC...

Страница 53: ...ctivity Blinking Overheat Solid On Fan Fail Blinking 1Hz Power Fail Blinking 1 4Hz Solid On Local UID On Solid On Remote UID On Blinking 1Hz Checking BMC BIOS Blinking 4HZ Recovering Updating BMC Blin...

Страница 54: ...us LED Button The Power On and BMC BIOS Status LED button is located on pins 1 and 2 of JF1 Momentarily contacting both pins will power on off the system or display BMC BIOS status Refer to the tables...

Страница 55: ...service Blinking blue 1Hz Remote UID is on Use this function to identify a unit from a remote location that might be in need of service BIOS BMC blinking blue 10Hz BIOS BMC recovery and or update in p...

Страница 56: ...LED 11 NIC 1 Activity LED 12 NIC 1 Link LED ID_UID Switch HDD LED The UID switch HDD LED connection is located on pins 13 and 14 of JF1 The UID switch is used for a chassis that supports a front UID...

Страница 57: ...NIC2 Activity LED NIC1 Link LED Key Key FP Power LED The Front Panel Power LED connection is located on pins 15 and 16 of JF1 Refer to the table below for pin definitions FP Power LED Pin Definitions...

Страница 58: ...IMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMMC1 P1 DIMMG1 P1 DIMMF1 P1 DIMME1 P1 DIMMH1 P2 DIMMG1 P2 DIMMC1 P2 DIMMD1 P2 DIMMB1 P2 DIMMA1 P2 DIMME1 P2 DIMMF1 P2 DIMMH1 CPU2 CPU1 CPU1 SLOT1 PCI E 4 0 X16 CPU2 SLOT...

Страница 59: ...PCIE4 JPCIE3 JPCIE2 JPCIE1 JF1 JUSBA JSD1 JSD2 JUSB1 JP7 JUSB31_I1 JLAN1 JPCIE6 JAUDIO1 JIPMB1 RAID KEY 1 I SATA5 I SATA4 I SATA3 I SATA2 I SATA1 I SATA0 I SATA6 I SATA7 LAN 1 2 HD AUDIO P2_NVME0 1 US...

Страница 60: ...USB0 1 2 3 3 0 VGA COM1 CMOS CLEAR TPM PORT80 JTPM1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMMC1 P1 DIMMG1 P1 DIMMF1 P1 DIMME1 P1 DIMMH1 P2 DIMMG1 P2 DIMMC1 P2 DIMMD1 P2 DIMMB1 P2 DIMMA1 P2 DIMME1 P2 DIMM...

Страница 61: ...1 P1 DIMME1 P1 DIMMH1 P2 DIMMG1 P2 DIMMC1 P2 DIMMD1 P2 DIMMB1 P2 DIMMA1 P2 DIMME1 P2 DIMMF1 P2 DIMMH1 CPU2 CPU1 CPU1 SLOT1 PCI E 4 0 X16 CPU2 SLOT2 PCI E 4 0 X16 CPU1 SLOT3 PCI E 4 0 X16 CPU2 SLOT4 PC...

Страница 62: ...VGA COM1 CMOS CLEAR TPM PORT80 JTPM1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMMC1 P1 DIMMG1 P1 DIMMF1 P1 DIMME1 P1 DIMMH1 P2 DIMMG1 P2 DIMMC1 P2 DIMMD1 P2 DIMMB1 P2 DIMMA1 P2 DIMME1 P2 DIMMF1 P2 DIMMH1 CP...

Страница 63: ...DIMMA1 P1 DIMMD1 P1 DIMMC1 P1 DIMMG1 P1 DIMMF1 P1 DIMME1 P1 DIMMH1 P2 DIMMG1 P2 DIMMC1 P2 DIMMD1 P2 DIMMB1 P2 DIMMA1 P2 DIMME1 P2 DIMMF1 P2 DIMMH1 CPU2 CPU1 CPU1 SLOT1 PCI E 4 0 X16 CPU2 SLOT2 PCI E 4...

Страница 64: ...P1 DIMME1 P1 DIMMH1 P2 DIMMG1 P2 DIMMC1 P2 DIMMD1 P2 DIMMB1 P2 DIMMA1 P2 DIMME1 P2 DIMMF1 P2 DIMMH1 CPU2 CPU1 CPU1 SLOT1 PCI E 4 0 X16 CPU2 SLOT2 PCI E 4 0 X16 CPU1 SLOT3 PCI E 4 0 X16 CPU2 SLOT4 PCI...

Страница 65: ...7 LAN 1 2 HD AUDIO P2_NVME0 1 USB7 3 1 LED PWR USB4 3 1 P1_NVME0 1 USB5 6 3 0 USB0 1 2 3 3 0 VGA COM1 CMOS CLEAR TPM PORT80 JTPM1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMMC1 P1 DIMMG1 P1 DIMMF1 P1 DIMME1...

Страница 66: ...I SATA7 LAN 1 2 HD AUDIO P2_NVME0 1 USB7 3 1 LED PWR USB4 3 1 P1_NVME0 1 USB5 6 3 0 USB0 1 2 3 3 0 VGA COM1 CMOS CLEAR TPM PORT80 JTPM1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMMC1 P1 DIMMG1 P1 DIMMF1 P1...

Страница 67: ...U2 SLOT2 PCI E 4 0 X16 CPU1 SLOT3 PCI E 4 0 X16 CPU2 SLOT4 PCI E 4 0 X16 CPU1 SLOT5 PCI E 4 0 X16 CPU2 SLOT6 PCI E 4 0 X8 PCH SATA Ports Six SATA 3 0 ports I SATA0 1 2 3 4 5 supported by the Intel C62...

Страница 68: ...DIMMG1 P2 DIMMC1 P2 DIMMD1 P2 DIMMB1 P2 DIMMA1 P2 DIMME1 P2 DIMMF1 P2 DIMMH1 CPU2 CPU1 CPU1 SLOT1 PCI E 4 0 X16 CPU2 SLOT2 PCI E 4 0 X16 CPU1 SLOT3 PCI E 4 0 X16 CPU2 SLOT4 PCI E 4 0 X16 CPU1 SLOT5 PC...

Страница 69: ...2 T SGPIO1 BT1 JPWR3 J37 SATA4 SATA6 SATA5 SATA8 SATA7 SATA1 SATA3 SATA2 JPWR2 JPWR1 JPWR4 JPRG1 JNVI2C JPME1 JPL1 JWD1 JPL2 JD1 JVRM1 JVRM2 JL1 JSPDIF_IN1 JSPDIF_OUT1 JTPM1 JA1 JRK1 LEDM1 LE4 LE7 JPI...

Страница 70: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearin...

Страница 71: ...NVME0 1 USB5 6 3 0 USB0 1 2 3 3 0 VGA COM1 CMOS CLEAR TPM PORT80 JTPM1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMMC1 P1 DIMMG1 P1 DIMMF1 P1 DIMME1 P1 DIMMH1 P2 DIMMG1 P2 DIMMC1 P2 DIMMD1 P2 DIMMB1 P2 DIMMA1...

Страница 72: ...4 3 1 P1_NVME0 1 USB5 6 3 0 USB0 1 2 3 3 0 VGA COM1 CMOS CLEAR TPM PORT80 JTPM1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMMC1 P1 DIMMG1 P1 DIMMF1 P1 DIMME1 P1 DIMMH1 P2 DIMMG1 P2 DIMMC1 P2 DIMMD1 P2 DIMMB1...

Страница 73: ...1 2 3 3 0 VGA COM1 CMOS CLEAR TPM PORT80 JTPM1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMMC1 P1 DIMMG1 P1 DIMMF1 P1 DIMME1 P1 DIMMH1 P2 DIMMG1 P2 DIMMC1 P2 DIMMD1 P2 DIMMB1 P2 DIMMA1 P2 DIMME1 P2 DIMMF1 P2...

Страница 74: ...SATA3 I SATA2 I SATA1 I SATA0 I SATA6 I SATA7 LAN 1 2 HD AUDIO P2_NVME0 1 USB7 3 1 LED PWR USB4 3 1 P1_NVME0 1 USB5 6 3 0 USB0 1 2 3 3 0 VGA COM1 CMOS CLEAR TPM PORT80 JTPM1 P1 DIMMB1 P1 DIMMA1 P1 DI...

Страница 75: ...1 DIMMC1 P1 DIMMG1 P1 DIMMF1 P1 DIMME1 P1 DIMMH1 P2 DIMMG1 P2 DIMMC1 P2 DIMMD1 P2 DIMMB1 P2 DIMMA1 P2 DIMME1 P2 DIMMF1 P2 DIMMH1 CPU2 CPU1 CPU1 SLOT1 PCI E 4 0 X16 CPU2 SLOT2 PCI E 4 0 X16 CPU1 SLOT3...

Страница 76: ...ween the motherboard and chassis 2 Disconnect all ribbon wire cables from the motherboard including those for the keyboard and mouse 3 Remove all add on cards 4 Install the CPU making sure it is fully...

Страница 77: ...by the system check the following 1 Make sure that the memory modules are compatible with the system and are properly installed See Chapter 2 for installation instructions For memory compatibility ref...

Страница 78: ...power to the system Make sure that all power connectors are connected Please refer to our website for more information on the minimum power requirements 6 Proper software support Make sure that the co...

Страница 79: ...was sold to you 1 Please go through the Troubleshooting Procedures and Frequently Asked Questions FAQ sections in this chapter or see the FAQs on our website http www supermicro com FAQ index php befo...

Страница 80: ...tion How do I update my BIOS Answer It is recommended that you do not upgrade your BIOS if you are not experiencing any problems with your system Updated BIOS files are located on our website at http...

Страница 81: ...ged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by your local hazardous was...

Страница 82: ...y displayed on the outside of the shipping carton and the shipping package is mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when servi...

Страница 83: ...ach main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured Th...

Страница 84: ...ime Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY form...

Страница 85: ...Chapter 4 BIOS 85 CPLD Version This item displays the Complex Programmable Logic Device version Memory Information Total Memory This item displays the total size of memory available in the system...

Страница 86: ...s feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal...

Страница 87: ...ely and allow the drives that are attached to these host adapters to function as bootable disks If this feature is set to Postponed the ROM BIOS of the host adapters will not capture Interrupt 19 imme...

Страница 88: ...Dynamic to allow or disallow this particular type of USB devices to be used in the rear USB ports without rebooting the system The options are Enabled Disabled and Enabled Dynamic EuP Energy Using Pr...

Страница 89: ...wing CPU information will display Processor BSP Revision Processor Socket Processor ID Processor Frequency Processor Max Ratio Processor Min Ratio Microcode Revision L1 Cache RAM L2 Cache RAM L3 Cache...

Страница 90: ...che lines for 64 bytes The options are Disable and Enable Note Refer to Intel s website for detailed information DCU Streamer Prefetcher If this feature is set to Enable the DCU Data Cache Unit stream...

Страница 91: ...re Unlock Enable and Lock Disable AES NI Select Enable to use the Intel Advanced Encryption Standard AES New Instructions NI to ensure data security The options are Enable and Disable TME TME MT TDX T...

Страница 92: ...TME MT is set to Enabled and the SGX feature is supported by the CPU used in the system Select Enabled to support Software Guard Extensions SGX for memory data security enhancement The options are Di...

Страница 93: ...ce bias tuning The options are OS Controls EPB or BIOS Controls EPB If the item above is set to BIOS Controls EPB the following item will be displayed ENERGY_PERF_BIAS_CFG Mode ENERGY PERFORMANCE BIAS...

Страница 94: ...le when SpeedStep is set to Enable Select enable to allow the CPU to operate at the manufacturer defined turbo speed by increasing CPU clock frequency This feature is available when it is supported by...

Страница 95: ...State is set to Disable Select Enable to enable Enhanced Halt State support which will significantly reduce the CPU s power consumption by minimizing CPU s clock cycles and reduce voltage during a Hal...

Страница 96: ...tion North Bridge This feature allows the user to configure Intel North Bridge parameters Uncore Configuration This section allows the user to configure the following Uncore settings Number of CPU Nu...

Страница 97: ...an attempt to save power This feature is available for the system that uses Intel processors with UPI technology support The options are Disable Enable and Auto Note You can change the performance set...

Страница 98: ...erate snoops instead of memory lockups for WCiLF Cores The options are Disable Auto Enable for Remote InvItoM Hybrid Push InvItoM AllocFlow Enable for Remote InvItoM Hybrid AllocNonAlloc and Enable fo...

Страница 99: ...this is the case a snoop will return the modified data However it may be the case that a line reads in an A state and all the snoops come back with a miss This can happen if another socket reads the l...

Страница 100: ...longer time to provide a permanent repair on a raw element The options are Soft PPR Hard PPR and PPR Disabled Memory Frequency Use this feature to set the maximum memory frequency for onboard memory...

Страница 101: ...cted installed in the system Select Enable to automatically restore the functionality and the features of NVDIMM modules The options are Enable and Disable Interleave NVDIMMs Available when Enabled AD...

Страница 102: ...instruction The options are Disabled and Enabled Mirror Mode Unavailable when UEFI ARM Mirror below is set to Enabled and ADDDC Sparing below is set to Disabled Use this feature to configure the mirro...

Страница 103: ...ed Patrol Scrub Patrol Scrubbing is a process that allows the CPU to correct correctable memory errors detected in a memory module and send the corrections to the requestor the original source When th...

Страница 104: ...to allow certain transactions to be processed and completed before other transactions that have already been enqueued The options are Yes and No Intel VT for Directed I O VT d Intel VT for Directed I...

Страница 105: ...enable Intel Volume Management Device Technology support for the root port The options are Enable and Disable Hot Plug Capable Select Enable to enable Hot Plug support for the root ports specified by...

Страница 106: ...will display for the port selected P1_NVME0 P1_NVME1 P1_M 2_0 P1_M 2_1 Available for onboard NVMe ports only Select Enable to enable Intel Volume Management Device Technology support for the root port...

Страница 107: ...4A 4B 4C 4D Available for onboard NVMe ports only Select Enable to enable Intel Volume Management Device Technology support for the root port The options are Enable and Disable Hot Plug Capable Select...

Страница 108: ...al and Non Fatal Error to enable IIO eDPC support when an error fatal or non fatal has occurred The options are On Fatal Error On Fatal and Non Fatal Errors and Disable If this feature is set to On Fa...

Страница 109: ...tions only The options are Enabled Disabled and Auto XHCI Hand Off This is a work around solution for operating systems that do not support XHCI Extensible Host Controller Interface hand off The XHCI...

Страница 110: ...he options are Enabled and Disabled Port 61h Bit 4 Emulation Select Enabled to enable the emulation of Port 61h bit 4 toggling in SMM System Management Mode The options are Disabled and Enabled Server...

Страница 111: ...oot Info Available when Configure SATA as is set to RAID Select Enable for full int13h support which will allow the system to boot using a device attached to the SATA controller The options are Disabl...

Страница 112: ...the device installed in the slot without shutting down the system The options are Enable and Disable Spin Up Device Select Enable for Staggered Spin Up support which will allow the SATA devices speci...

Страница 113: ...e 4G Address The options are Enabled and Disabled SR IOV Support Available if the system supports Single Root Virtualization Select Enabled for Single Root IO Virtualization support The options are En...

Страница 114: ...e of M 2 drive EFI OpROM firmware The options are Vendor defined Firmware and AMI Native Support VGA Priority Use this feature to select the graphics device to be used as the primary video display for...

Страница 115: ...ector specified by the user The options are Disabled and EFI Onboard LAN1 Option ROM Onboard LAN2 Option ROM Select PXE to boot up your system using a legacy device installed on LAN 1 port and LAN 2 p...

Страница 116: ...4 IO 2F8h IRQ 4 IO 3E8h IRQ 4 and IO 2E8h IRQ 4 Serial Port 2 Configuration Serial Port Select Enabled to enable Serial Port 1 The options are Enabled and Disabled Device Settings Available when Seri...

Страница 117: ...ing items will become available for configuration Console Redirection Settings Terminal Type Use this feature to select the target terminal emulation type for Console Redirection Select VT100 to use t...

Страница 118: ...along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the n...

Страница 119: ...sabled and Enabled Putty KeyPad This feature selects Function Keys and KeyPad settings for Putty which is a terminal emulator designed for the Windows OS The options are VT100 LINUX XTERMR6 SCO ESCN a...

Страница 120: ...along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the n...

Страница 121: ...Enabled to enable VT UTF8 Combination Key support for ANSI VT100 terminals The options are Enabled and Disabled Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as...

Страница 122: ...Services EMS The feature allows the user to configure Console Redirection settings to support Out of Band Serial Port management Console Redirection for EMS Select Enabled to use a COM port specified...

Страница 123: ...he options are 9600 19200 57600 and 115200 bits per second Flow Control Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop sign...

Страница 124: ...the UMA Uniform Memory Access Based Clustering option The options are Hemisphere 20clusters and Disabled All2All WHEA Support Select Enabled to support the Windows Hardware Error Architecture WHEA pl...

Страница 125: ...and data security If there is a TPM jumper installed on the motherboard please also enable the jumper for this feature to work properly Please note that the OS will not show the security device when t...

Страница 126: ...ecurity of the platform firmware used in a host system via a TPM device The options are Enabled and Disabled Storage Hierarchy Select Enabled for TPM Storage Hierarchy support that is intended to be u...

Страница 127: ...ta security The options are Disabled and Enabled Note 1 If the option for this feature TXT Support is set to Enabled be sure to dis able EV DFX Device Function On Hide support when it is present in th...

Страница 128: ...Pv6 PXE boot option The options are Disabled and Enabled IPv6 HTTP Support Select Enabled to enable IPv4 HTTP boot support If this feature is disabled it will not create the IPv6 HTTP boot option The...

Страница 129: ...t IPv4 or IPv6 Use this feature to select Internet Protocol version for the targeted LAN port The options are IPv6 and IPv4 Boot Description Use this feature to input description for the HTTP Boot Max...

Страница 130: ...is to be used by the server Enroll Cert This feature allows the user to enroll the certificate in the system Enroll Cert Certification Using File This feature allows the user to enroll the security c...

Страница 131: ...ws the user to enroll the certificate in the system Enroll Cert Certification Using File This feature allows the user to enroll the security certificate in the system by using a file Cert Certificatio...

Страница 132: ...ink Speed This feature displays the connection speed of a LAN port specified by the user Wake On LAN If this feature is set to Enabled the LAN port specified by the user will be enabled when the syste...

Страница 133: ...Chapter 4 BIOS 133 UEFI Driver Adapter PBA Device Name Chip Type PCI Device ID PCI Address Link Status MAC Address Virtual MAC Address...

Страница 134: ...ID Enter a valid value between 0 4094 Priority Use this feature to enter the 802 1Q Priority Enter a valid value between 0 7 Add VLAN This feature allows the user to add a new VLAN Configured VLAN Lis...

Страница 135: ...display Interface Name Interface Type MAC Address Host Addresses Route Table Gateway Addresses DNS Addresses Interface ID This feature displays the Interface ID used in the network DAD Duplicate Addr...

Страница 136: ...er s Manual 136 Policy Use this feature to select how the policy is to be configured The options are Automatic and Manual Save Changes and Exit Select Yes to save the changes that you ve made and exit...

Страница 137: ...search for a DHCP server attached to the network and request the next available IP address for this computer The options are Disabled and Enabled Local Address Use this feature to enter an IP address...

Страница 138: ...isplayed Option ROM Version Unique NVM EEPROM ID NVM Version NIC Configuration Link Speed This feature displays the connection speed of a LAN port specified by the user Wake On LAN If this feature is...

Страница 139: ...ays the number of blinking LED indicators of the LAN port specified by the user The following information will be displayed as well UEFI Driver Adapter PBA Device Name Chip Type PCI Device ID PCI Addr...

Страница 140: ...LAN ID by using an existing VLAN or creating a new VLAN ID Enter a valid value between 0 4094 Priority Use this feature to enter the 802 1Q Priority Enter a valid value between 0 7 Add VLAN This feat...

Страница 141: ...display Interface Name Interface Type MAC Address Host Addresses Route Table Gateway Addresses DNS Addresses Interface ID This feature displays the Interface ID used in the network DAD Duplicate Addr...

Страница 142: ...er s Manual 142 Policy Use this feature to select how the policy is to be configured The options are Automatic and Manual Save Changes and Exit Select Yes to save the changes that you ve made and exit...

Страница 143: ...search for a DHCP server attached to the network and request the next available IP address for this computer The options are Disabled and Enabled Local Address Use this feature to enter an IP address...

Страница 144: ...Super X12DAi N6 User s Manual 144 Driver Health This feature displays the following driver health information...

Страница 145: ...Event Log Settings Enabling Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Enabled and Disabled Erasing Sett...

Страница 146: ...The options are Enabled and Disabled MECI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multipl...

Страница 147: ...installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings Erase SE...

Страница 148: ...tting is Dedicated LAN Configuration Address Source This feature allows the user to select the source of the IP address for this computer If Static is selected you will need to know the IP address of...

Страница 149: ...and Disabled Configuration Address Source This feature allows the user to select the source of the IP address for this computer If Static is selected you will need to know the IP address of this compu...

Страница 150: ...hen an Administrator Password is entered This feature indicates if a user s password has been installed It also allows the user to set the user s password which is required to enter the BIOS setup uti...

Страница 151: ...ord Security Function Select Password to set an HDD SATA password which will allow the user to configure the security settings of the HDD SATA device Select Security Erase Password to enter a SATA use...

Страница 152: ...nuals When you select this submenu and press the Enter key the following items will display Secure Mode Secure Boot Select Enabled to use Secure Boot settings The options are Enabled and Disabled Secu...

Страница 153: ...the system to Setup Mode The options are Yes and No Enter Audit Mode This feature to set the system to boot into the Audit Mode Key Management Available when Secure Boot Mode is set to Custom Vendor K...

Страница 154: ...aults Select Yes to restore database variables to the manufacturer default settings The options are Yes and No Secure Boot Variable Size Keys Key Source Platform Key PK Use this feature to enter and c...

Страница 155: ...s Select Append to append your Forbidden Signatures The options are Details Export Update Append and Delete Authorized TimeStamps This feature allows the user to set and save the timestamps for the au...

Страница 156: ...e device from which the system will boot Press Enter on each item sequentially to select devices When the feature Boot Mode Select is set to Dual default the following items will be displayed for the...

Страница 157: ...ows the user to remove an EFI boot option from the boot priority list Delete Driver Option This feature allows the user to select a boot driver to delete from the boot priority list Delete Drive Optio...

Страница 158: ...er Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility and reboot the computer for the new system configuration parameter...

Страница 159: ...all changes on the default values entered by the user to the BIOS setup utility for future use Restore the User Defaults To set this feature select Restore the User Default Values from the Exit menu...

Страница 160: ...upermicro com support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a...

Страница 161: ...at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash...

Страница 162: ...river browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the...

Страница 163: ...rred Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash dri...

Страница 164: ...s alerts via email or Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With Supe...

Страница 165: ...nfo BMC cfm B 5 Logging into the BMC Baseboard Management Controller Supermicro ships standard products with a unique password for the BMC ADMIN user This password can be found on a label on the mothe...

Страница 166: ...fore installing or configuring components These warnings may also be found on our website at http www supermicro com about policies safety_information cfm Battery Handling Warnung Bei Einsetzen einer...

Страница 167: ...ffingsgevaar indien de batterij verkeerd vervangen wordt Vervang de batterij slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen wordt Gebruikte batterijen dienen overeenkoms...

Страница 168: ...tos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent...

Отзывы: