background image

X10SDE-DF User's Manual

50

Power/Performance Switch

This feature allows dynamic switching between Power and Performance power efficiency. 

The options are Disable and 

Enable

.

Workload Configuration

This feature allows for optimization of workload. Balanced is recommended. The options 
are 

Balanced 

and I/O Sensitive.

Program PowerCTL_MSR

PKG C-state Lat. Neg.

Use this feature to indicate whether latency should be negotiated with PCH for packaging 
C-States. The options are 

Enable

 and Disable.

SAPM Control

This feature indicates whether the PCU should control the System Agent PM using its 
power-performance tuning algorithm. The options are 

Enable

 and Disable.

Energy Efficient Turbo

Use  this  feature  to  enable  energy  efficient  turbo  mode.  The  options  are 

Enable

 and 

Disable.

DRAM RAPL Configuration

Override BW_LIMIT_TF

Use this feature to allow custom tuning of BW_LIMIT_TF when DRAM RAPL is enabled. 
Press the "+" or "-" key to change the value. The default value is 

1

DRAM RAPL Extended Range

Use this feature to set the DRAM Running Average Power Limit (RAPL) Extended Range. 
The options are Disable and 

Enable

Chipset Configuration

Warning: 

Setting the wrong values in the following features may cause the system to malfunc-

tion.

North Bridge

This feature allows the user to configure the following North Bridge settings.

Содержание X10SDE-DF

Страница 1: ...USER MANUAL Revision 1 0a X10SDE DF...

Страница 2: ...s operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may c...

Страница 3: ...ed by professional technicians only For processor memory updates please refer to our website at http www supermicro com products Conventions Used in the Manual Special attention should be given to the...

Страница 4: ...puter B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma...

Страница 5: ...nitor with Firmware Control 16 Environmental Temperature Control 16 System Resource Alert 16 1 5 ACPI Features 16 1 6 Power Supply 17 1 7 Serial Port 17 Chapter 2 Installation 2 1 Static Sensitive Dev...

Страница 6: ...3 3 Frequently Asked Questions 38 3 4 Battery Removal and Installation 39 3 5 Returning Merchandise for Service 40 Chapter 4 BIOS 4 1 Introduction 41 4 2 Main Setup 42 4 3 Advanced Setup Configuration...

Страница 7: ...anything listed is damaged or missing please contact your retailer 1 1 Checklist Important Links For your system to work properly please follow the links below to download all necessary drivers utilit...

Страница 8: ...herboard Image Note All graphics shown in this manual were based upon the latest PCB revision available at the time of publication of the manual The motherboard you received may or may not look exactl...

Страница 9: ...1 00 J27 P1 JBT1 P1 JPME1 P1 JPME2 P2 JPME2 P2 JPME1 P1 BT1 P2 BT1 P2 JBT1 P2 DIMMA1 P2 DIMMA2 P2 DIMMB1 P2 DIMMB2 P1 DIMMB2 P1 DIMMB1 P1 DIMMA2 P1 DIMMA1 BAR CODE MAC CODE MAC CODE P1 JPL1 LEDM2 LED...

Страница 10: ...id possible explosion BMC SW2 CPU2 CPU1 X10SDE DF Rev 1 00 J27 P1 JBT1 P1 JPME1 P1 JPME2 P2 JPME2 P2 JPME1 P1 BT1 P2 BT1 P2 JBT1 P2 DIMMA1 P2 DIMMA2 P2 DIMMB1 P2 DIMMB2 P1 DIMMB2 P1 DIMMB1 P1 DIMMA2 P...

Страница 11: ...P2 JWD1 Watch Dog Enable Pins 1 2 Reset LED Description Status LED7 UID LED Blue Blinking Unit Identified LED8 Overheat Power Fail LED Bottom of the board Red Solid On Overheat Blink Power Fail LEDM1...

Страница 12: ...B for RDIMM memory or up to 64GB for UDIMM memory at 1 2V Note 1 Memory speed support depends on the processors used in the system Note 2 For the latest CPU memory updates please refer to our website...

Страница 13: ...Platform Service LED Indicators CPU system overheat LED Power suspend state indicator LED UID remote UID LED LAN activity LED Dimensions 18 495 L x 4 66 W 469 773 mm x 118 364 mm Note 1 The CPU maximu...

Страница 14: ...PI B1 B2 DIMMB1 DIMMB2 DIMMA1 DIMMA2 LPC LPC SOC PEG 4 AST2400 PCIE x 1 COM2 UART1 UART2 TX RX debug 0Ohm NI FLASH 128Mbit VGA1 SPI COM1 LPC AST2400 UART1 UART2 TX RX debug PCIE x 1 0Ohm NI COM USB VG...

Страница 15: ...mption Server Class Reliability Availability and Serviceability RAS Intel Hyper Threading Intel Turbo Boost and AVX2 Intel Virtualization Technology VT x VT d 10 Gigabit Ethernet Controller Built In D...

Страница 16: ...sure to provide adequate air flow to your system System Resource Alert This feature is available when used with SuperDoctor 5 SuperDoctor 5 is used to notify the user of certain system events For exam...

Страница 17: ...may choose to install a line filter to shield the computer from noise It is recommended that you also install a power surge protector to help avoid problems caused by power surges 1 7 Serial Port The...

Страница 18: ...uch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the motherboard and peripherals back into their antistatic bags when no...

Страница 19: ...es for both the motherboard and the chassis match Although a chassis may have both plastic and metal mounting fasteners metal ones are highly recommended because they ground the motherboard to the cha...

Страница 20: ...o avoid damaging motherboard components 4 Insert a Pan head 6 screw into a mounting hole on the motherboard and its matching mounting hole on the chassis using the Philips screwdriver 5 Repeat Step 4...

Страница 21: ...MMB2 Populating these DIMM modules with a pair of memory modules of the same type and size will result in interleaved memory which will improve memory performance DIMM Module Population Configuration...

Страница 22: ...lot Towards the edge of the motherboard Towards the CPU DIMMB2 DIMMA2 DIMM Module Population Sequence When installing memory modules the DIMM slots must be populated in the following order P1 DIMMA1 P...

Страница 23: ...P2 DIMMA2 P2 DIMMB2 For the system to work properly please use memory modules of the same type and speed on the motherboard 2 Push the release tabs outwards on both ends of the DIMM slot to unlock it...

Страница 24: ...KVM SW1 P2 Power LED P1 Power LED IPMI_LAN P1 JPB1 P2 JPL1 LED7 P2 JPB1 P1 LAN1 P2 LAN1 P1 LAN2 P2 LAN2 BMC i350 LAN i350 LAN P1 JBR1 P2 JBR1 2 4 Front I O Ports See Figure 2 2 below for the location...

Страница 25: ...e 1 are located at P1 LAN1 and P1 LAN2 LAN ports 1 2 for Node 2 are located at P2 LAN1 and P2 LAN2 In addition an IPMI LAN port which provides a network connection via the IPMI 2 0 interface is locate...

Страница 26: ...T1 P1 JPME1 P1 JPME2 P2 JPME2 P2 JPME1 P1 BT1 P2 BT1 P2 JBT1 P2 DIMMA1 P2 DIMMA2 P2 DIMMB1 P2 DIMMB2 P1 DIMMB2 P1 DIMMB1 P1 DIMMA2 P1 DIMMA1 BAR CODE MAC CODE MAC CODE P1 JPL1 LEDM2 LEDM1 P2 JPG1 P1 J...

Страница 27: ...tween two pins to change the function of the connector Pin 1 is identified with a square solder pad on the printed circuit board See the diagram below for an example of jumping pins 1 and 2 Refer to t...

Страница 28: ...table below for jumper settings The default setting is Enabled VGA Enable Disable Jumper Settings Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled CMOS Clear P1 JBT1 is used to clear the s...

Страница 29: ...to reset the system if an application hangs Close pins 2 3 of P1 JWD1 or P2 JWD1 to generate a non maskable interrupt signal for the application that hangs Refer to the table below for jumper setting...

Страница 30: ...ble Node 1 2 BMC Enable Disable Node 2 3 LAN Enable Disable Node 1 4 LAN Enable Disable Node 2 2 LAN Ports Enable Disable Jumper JPL1 enables or disables Ethernet LAN ports on the motherboard P1 JPL1...

Страница 31: ...ins 2 3 ME Recovery Management Engine ME Recovery Set jumpers P1 JPME1 P2 JPME1 to select ME Firmware Recovery mode for Node 1 P1 JPME1 or Node 2 P2 JPME1 ME Recovery limits system resource for essent...

Страница 32: ...right indicates the link The Activity LED on the left may be green amber or off to indicate the speed Refer to the tables below for more information 1 P1 LAN1 LAN2 LEDs 2 P2 LAN1 LAN2 LEDs 3 IPMI LAN...

Страница 33: ...on the motherboard Press the UID button again to turn off the LED Indicator The UID Indicator provides easy identification of a system unit that may be in need of service Note UID can also be trigger...

Страница 34: ...olor State Definition Green Blinking BMC Normal 1 BMC LED Node 1 2 BMC LED Node 2 2 1 BMC Heartbeat LEDs Two BMC Heartbeat LEDs are located on the motherboard When LEDM1 is blinking the BMC is functio...

Страница 35: ...motherboard and chassis 3 Disconnect all ribbon wire cables from the motherboard including those for the keyboard and mouse Also be sure to remove all add on cards 4 Install a CPU and heatsink be sure...

Страница 36: ...t sizes different speeds and different types on the same motherboard 3 Check for bad DIMM modules or slots by swapping modules between slots to see if you can locate the faulty ones 4 Check the switch...

Страница 37: ...in this chapter or see the FAQs on our website before contacting Technical Support 2 BIOS upgrades can be downloaded from our website Note Not all BIOS can be flashed depending on the modifications t...

Страница 38: ...humb drive To flash the BIOS run the batch file named flash bat with the new BIOS ROM file from your bootable device or USB pen thumb drive Use the following format F flash bat BIOS ROM filename xxx E...

Страница 39: ...e the battery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set...

Страница 40: ...ly displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when service is complete For fast...

Страница 41: ...c Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured...

Страница 42: ...nd time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY...

Страница 43: ...Chapter 4 BIOS 43 Memory Information Total Memory This item displays the total size of memory available in the system Memory Speed This item displays the memory speed...

Страница 44: ...ure to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST m...

Страница 45: ...e Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function If enabled the Watch Dog Timer will allow the system to reset or generate NMI based on jumper settings when it is expired for...

Страница 46: ...mation Enter 0 to enable all cores Monitor Mwait Select Enabled to enable the Monitor MWait instructions The Monitor instruction monitors a region of memory for writes and MWait instructions instruct...

Страница 47: ...DCU Data Cache Unit IP Prefetcher support which will prefetch IP addresses to improve network connectivity and system performance The options are Disable and Enable Direct Cache Access DCA Select Enab...

Страница 48: ...HW_All SW_ALL and SW_ANY Energy Efficient P State Select Enable to support power saving mode for P State The options are Disable and Enable Boot Performance Mode This feature allows the user to select...

Страница 49: ...which will significantly reduce the CPU s power consumption by reducing the CPU s clock cycle and voltage during a Halt state The options are Disable and Enable CPU T State Control ACPI Advanced Confi...

Страница 50: ...l the System Agent PM using its power performance tuning algorithm The options are Enable and Disable Energy Efficient Turbo Use this feature to enable energy efficient turbo mode The options are Enab...

Страница 51: ...ected I O VT d Intel VT for Directed I O VT d Select Enable to use Intel Virtualization Technology support for Direct I O VT d support by reporting the I O device assignments to the VMM Virtual Machin...

Страница 52: ...dle states The options are Disabled and CLTT Closed Loop Thermal Throttling A7 Mode Select Enabled to support the A7 Addressing mode to improve memory performance The options are Disable and Enable DI...

Страница 53: ...gging that generates stuck bits or hard errors The options are Disable and Enable South Bridge The following South Bridge information will display USB Configuration USB Module Version USB Devices Lega...

Страница 54: ...are Enabled and Disabled Configure SATA as Select IDE to configure a SATA drive specified by the user as an IDE drive Select AHCI to configure a SATA drive specified by the user as an AHCI drive Sele...

Страница 55: ...item to allow the PCH to initialize the device The options are Enabled and Disabled P1 SATA0 P1 SATA1 SATA Device Type Use this item to specify if the SATA port specified by the user should be connec...

Страница 56: ...abled and Enabled ARI Forwarding When this feature is enabled the Downstream Port disables its traditional device number to 0 when turning Type1 Configuration Request into a Type0 Configuration Reques...

Страница 57: ...abled and Disabled IPv6 PXE Support Select Enabled to enable IPv6 PXE boot support The options are Enabled and Disabled PXE boot wait time Use this option to specify the wait time to press the ESC key...

Страница 58: ...eature allows the user to specify how the host computer will exchange data with the client computer which is the remote computer used by the user Terminal Type This feature allows the user to select t...

Страница 59: ...ta when the receiving buffer is empty The options are None and Hardware RTS CTS VT UTF8 Combo Key Support Select Enabled to enable VT UTF8 Combination Key support for ANSI VT100 terminals The options...

Страница 60: ...Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 38400 57600...

Страница 61: ...acy OS Redirection Resolution Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support The options are 80x24 and 80x25 Putty KeyPad This feature sele...

Страница 62: ...to use the extended ASCII character set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are VT100 VT100 VT UTF8 and ANSI Bits Per Second This item sets...

Страница 63: ...nabled to activate the High Performance Event Timer HPET that produces periodic interrupts at a much higher frequency than a Real time Clock RTC does in synchronizing multimedia streams providing smoo...

Страница 64: ...ng Support Select Enable to support Runtime Error Logging The options are Enable and Disable If this item is set to Enable the following item will be available for configuration Memory Corrected Error...

Страница 65: ...is full The options are Do Nothing and Erase Immediately SMBIOS Event Long Standard Settings Log System Boot Event This option toggles the System Boot Event logging to enabled or disabled The options...

Страница 66: ...firmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Setting...

Страница 67: ...et to Yes Configuration Address Source and VLAN options become available for user configuration Configuration Address Source This feature allows the user to select the source of the IP address for thi...

Страница 68: ...IP Address This item displays the Gateway IP address for this computer This should be in decimal and in dotted quad form i e 172 31 0 1 VLAN Use this item to enable or disable the IPMI VLAN function...

Страница 69: ...he BIOS Setup utility The options are Setup and Always Administrator Password Press Enter to create a new or change an existing Administrator password CSM Support Select Enabled to support the EFI Com...

Страница 70: ...is feature allows the user to decide if all secure boot variables should be saved Platform Key PK This feature allows the user to configure the settings of the platform keys Set New Key Select Yes to...

Страница 71: ...le The options are Yes and No Append Key Select Yes to add the DBX from the manufacturer s defaults to the existing DBX Select No to load the DBX from a file The options are Yes and No Authorized Time...

Страница 72: ...l The default setting is Dual FIXED BOOT ORDER Priorities This option prioritizes the order of bootable devices that the system to boot from Press Enter on each entry from top to bottom to select devi...

Страница 73: ...al Boot Order 15 Delete Boot Option Use this feature to remove a pre defined boot device from which the system will boot during startup The settings are any pre defined boot device NETWORK Drive BBS P...

Страница 74: ...ter Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility and reboot the computer so the new system configuration parameter...

Страница 75: ...t Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defa...

Страница 76: ...the Supermicro website at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and utilities After creating a CD DVD with the ISO...

Страница 77: ...umption and fan speed and provides alerts via email or the Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize y...

Страница 78: ...talling or configuring components These warnings may also be found on our website at http www supermicro com about policies safety_information cfm Battery Handling Warnung Bei Einsetzen einer falschen...

Страница 79: ...evaar indien de batterij verkeerd vervangen wordt Vervang de batterij slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fab...

Страница 80: ...nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Waa...

Страница 81: ...ecovering the UEFI BIOS Image An AMIBIOS flash chip consists of a boot sector block and a main BIOS code block a main BIOS image The boot sector block contains critical BIOS codes including memory det...

Страница 82: ...nto your USB drive and power on the system 3 While powering on the system keep pressing Ctrl and Home simultaneously on your PS2 or USB keyboard until your hear two short beeps This may take from a fe...

Страница 83: ...American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 12 1211 Copyright C 2011 American Meg...

Страница 84: ...from the power supply clear CMOS then plug the AC power cable in the power supply again to power on the system 10 Press Del continuously to enter the BIOS Setup utility 11 Press F3 to load the default...

Отзывы: