11
Chapter 1: Introduction
1.2 System Features
The following views of the system display the main features. Refer to
Appendix B
for additional
specifications.
Front View
Figure 1-1. Front View
Logical Storage Drive Numbers
Item
Description
0-5
3.5" hot-swap SAS3*/SATA/NVMe* drive bays (NVMe from CPU1)
6-11
3.5" hot-swap SAS3*/SATA/NVMe* drive bays (NVMe from CPU2)
* SAS3 and NVMe support requires with additional parts
Drive Carrier Indicators
Each drive carrier has two LED indicators: an activity indicator and a status indicator. For RAID
configurations using a controller, the meaning of the status indicator is described in the table
below. For OS RAID or non-RAID configurations, some LED indications are not supported,
such as hot spare. For VROC configurations, refer to the
VROC section
in this manual.
Drive Carrier LED Indicators
Color
Blinking Pattern
Behavior for Device
Activity
LED
Blue
Solid On
Idle SAS or NVMe drive installed
Blue
Blinking
I/O activity
Off
Idle SATA or no drive
10
11
1
2
4
7
0
3
5
8
9
6
Control Panel
Service/Asset Tag
with BMC Password