Страница 1: ...USER S MANUAL Revision 1 0 SuperServer E50 9AP...

Страница 2: ...a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful...

Страница 3: ...lities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities ftp ftp supermicro com Product safety info http www superm...

Страница 4: ...Precautions 14 Installing Components to your System 14 Installing Mounting Brackets 15 Chapter 2 Maintenance and Component Installation 2 1 Removing Power 16 2 2 Accessing the System 16 2 3 Motherboar...

Страница 5: ...tion 38 Starting the Setup Utility 38 5 2 Main Page 39 5 3 Advanced Page 40 5 4 Security 59 5 5 Boot 63 5 6 Save Exit 65 Appendix A BIOS Error Codes Appendix B Standardized Warning Statements for DC S...

Страница 6: ...B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma superm...

Страница 7: ...at are included with the system are listed below Main Parts List Description Part Number Quantity Power Adapter MCP 250 10124 0N 1 Add on I O Module AOM PICO 01 P 1 Important Links For your system to...

Страница 8: ...tel Atom x5 E3940 System on Chip Socket BGA Cooling Fan less design Memory Supports up to 8GB DDR3L Non ECC SODIMM 1866MHz memory in one DIMM slot Expansion Slots One full size Mini PCI e slot One hal...

Страница 9: ...es Item Features Description 1 Power Button The main power switch applies or removes primary power from the power supply to the server but maintains standby power To perform most maintenance tasks unp...

Страница 10: ...re 1 2 Rear I O Rear I O Features Item Features Description 1 Power Input Port Use this port for the 12V DC power input 2 USB USB 3 0 Port 3 USB USB 3 0 Port 4 HDMI HDMI High Definition Multimedia Int...

Страница 11: ...able on the following page for descriptions For detailed descriptions pinout information and jumper settings refer to Chapter 3 Figure 1 3 Motherboard Layout Note Components not documented are for int...

Страница 12: ...udio Header Mic In Line out J6 Two USB 2 0 Headers JCOM1 Two COM Headers two RS232 422 485 JDC 12V DC Jack Power Connector JEIO1 Supermicro Extension I O HDMI DP two PCI E x1 two USB 2 0 LPC SATA SMBu...

Страница 13: ...2 LAN2 INTEL I210 PCIE 2 GLAN2 LAN1 INTEL I210 RJ45 JLAN2 PCIE 1 PCIe Gen2 x 1 5 0GT s PCIe Gen2 x 1 USB2 0 4 5 5 0GT s DDI1 PCIe Gen2 x 2 PCIE 4 5 EIO 2 ports PCIe X1 2 ports USB 2 0 HDMI LPC SATA SM...

Страница 14: ...Review the electrical and general safety precautions in Appendix B Installing Components to your System Memory If your system is not already fully integrated with system memory refer to Chapter 2 for...

Страница 15: ...rackets that allow it to be mounted in any convenient space 1 Install the brackets to the chassis with two screws in each bracket 2 Secure the brackets to the surface where you want the system to be m...

Страница 16: ...step is necessary when removing or installing non hot swap components or when replacing a non redundant power supply 1 Use the operating system to power down the system 2 After the system has complet...

Страница 17: ...d Components Processor The E50 9AP features an embedded Intel Atom x5 E3940 processor Memory Support The A2SAP H supports up to 8GB of DDR3L Non ECC SO DIMM with speeds of up to 1866MHz in one memory...

Страница 18: ...g Memory Caution Exercise extreme care when installing or removing DIMM modules to prevent damage Align SO DIMM Installation 1 Position the SODIMM module s bottom key so it aligns with the receptive p...

Страница 19: ...own until the module locks into place Locking clip Figure 2 3 M 2 B Key 2242 and Half size MiniPCIe 2 Insert the SODIMM module vertically at a 45 degree angle Press down until the module locks into pl...

Страница 20: ...e Drive The E50 9AP supports one 2 5 SSD 7 mm in height Installing the M 2 Card 1 Gently insert the M 2 card into the connector 2 Use a screw to secure the M 2 card to the M2_SRW1 or M2_SRW2 standoff...

Страница 21: ...d by a lithium battery residing on the motherboard M 2 E key 2230 and Mini PCIe The E50 9AP supports one M 2 key 2230 and one full size Mini PCIe Installation 1 Gently insert the M 2 E Key 2230 card t...

Страница 22: ...ponent locations can be found in Chapter 1 Review the Safety Precautions in Appendix B before installing or removing components 3 1 Ports LAN Ports Two LAN ports JLAN1 JLAN2 are located on the I O bac...

Страница 23: ...e USB access with a cable Two USB 2 0 cables for front panel support are included with the motherboard JDC This is a DC jack that functions as the 12V power connector 12V Stdby Power Pin Definition Pi...

Страница 24: ...ther Link LED may be green amber or off to indicate the speed of the connection LAN1 2 LED Connection Speed Indicator LED Color Definition Off 10 Mb s Green 100 Mb s Amber 1 Gb s Power LED LED1 is the...

Страница 25: ...JCOM1 header provides two RS232 422 485 COM connections Refer to the table below for pin definitions Refer to pins 1 10 for COM1 and pins 11 20 for COM2 Audio Header Pin Definition Pin Definition Pin...

Страница 26: ...ed digital interface that operates at low power It is a type of connection that is used with a LVDS LCD panel LVDS Connector Pin Definitions Pin Definition Pin Definition 39 GND 40 GND 37 LVDSB D3N 38...

Страница 27: ...designed for internal mounting devices The A2SAP H motherboard deploys a B KEY for SATA PCI E SSD devices or USB PCI E WWAN or GNSS card The A2SAP H deploys a 2280 screw hole location for a 2280 M 2 m...

Страница 28: ...0 11 GND 12 GND 13 CLK_100M_EIO_DP 14 USB_P5_DP 15 CLK_100M_EIO_DN 16 USB_P5_DN 17 GND 62 GND 18 USB_P4_DP 19 DDI1_TXP2 20 USB_P4_DN 21 DDI1_TXN2 22 GND 23 GND 24 DDI1_TXP3 25 DDI1_TXP1 26 DDI1_TXN3 2...

Страница 29: ...ee the table below for pin definitions Mini PCI E Pin Definition Pin Definition Pin Definition 52 3 3Vaux 51 NC 50 GND 49 NC 48 1 5V 47 NC 46 NC 45 NC 44 NC 43 NC 42 NC 41 3 3Vaux 40 GND 39 NC 38 USB_...

Страница 30: ...agement Bus header for additional slave devices or sensors is located at JSMBUS1 on the bottom side of the motherboard This header also serves as a 5V SATA power box header Refer to the table below fo...

Страница 31: ...L 0000 PRX PINREX 225 97 16GBEW CNT PIN HEADER 2X16 PIN PITCH 2MM VERT 1A PIN BLACK GF NY6T SMD CM 30 75C ROHS Female Mating Connector HDR 0210L 0000 PRX PINREX 620 92 16GB00 CNT PIN FEMALE HEADER 2X1...

Страница 32: ...EX 225 97 17GBEW CNT PIN HEADER 2X17 PIN PITCH 2MM VERT 1A PIN BLACK GF NY6T SMD CM 30 75C ROHS Female Mating Connector on I O Module HDR 0211L 0000 PRX PINREX 620 92 17GB00 CNT PIN FEMALE HEADER 2X17...

Страница 33: ...LED indicators Power Button 1 Reset Button 2 HDD LED Power LED Reset PWR 3 3V 3 3V Stby Ground Ground 7 8 Power Button The Power Button connection is located on pins 1 and 2 of JF1 Momentarily contact...

Страница 34: ...ition 3 Reset 4 Ground Power LED The Power LED connection is located on pins 7 and 8 of JF1 Refer to the table below for pin definitions Power LED Pin Definition JF1 Pin Definition 7 3 3VSB 8 Power LE...

Страница 35: ...the pins Connector Pins Jumper Setting 3 2 1 3 2 1 JLCDPWR1 Use this jumper to select the power voltage for the LVDS panel Make sure that the specifications of the cable is compatible with the panel t...

Страница 36: ...a DVD of the drivers and utilities it contains You may also use a utility to extract the ISO file if preferred After creating a DVD with the ISO files insert the disk into the DVD drive on your system...

Страница 37: ...nd Linux operating systems The program monitors system health information such as CPU temperature system voltages system power consumption fan speed and provides alerts via email or Simple Network Man...

Страница 38: ...few cases when other keys are used such as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be...

Страница 39: ...tem Date System Time Use this option to change the system date and time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow key...

Страница 40: ...ure to select the screen display between POST messages or the OEM logo at bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST messages...

Страница 41: ...abled and EFI Boot Power Configuration Watch Dog Function If enabled the Watch Dog timer will allow the system to reboot when it is inactive for more than 5 minutes The options are Disabled and Enable...

Страница 42: ...e Disabled and Enabled Turbo Mode Select Enabled for processor cores to run faster than the frequency specified by the manufacturer The options are Disabled and Enabled Boot performance mode This feat...

Страница 43: ...omputer The options are Disabled and Enabled VT d Select Enabled to enable Intel Virtualization Technology support for Direct I O VT d by reporting the I O device assignments to VMM through the DMAR A...

Страница 44: ...EFI protocols The options are Enable and Disable LVDS Panel Support Use this feature to select the supported IGFX graphics device ouput to the LVDS panel The options are Disabled and Enabled Panel Sup...

Страница 45: ...448M 480M and 512M DVMT Total Gfx Mem Use this feature to set the total memory size to be used by internal graphics devices based on the DVMT 5 0 platform The options are 128MB 256MB and MAX GT PM Sup...

Страница 46: ...d for the device installed in the M 2 slot The op tions are Auto Gen1 and Gen2 Intel I210 Gigabit LAN ASPM Use this item to set the Active State Power Management ASPM level for a PCI E de vice Select...

Страница 47: ...ation USB3 0 Support Select Enable for USB 3 0 support The options are Enable and Disable XHCI Pre Boot Driver Select Enabled to enable XHCI Extensible Host Controller Interface support on a pre boot...

Страница 48: ...allow the user to replace a SATA drive without shutting down the system The options are Enabled and Disabled Spin Up Device When the value of an edge detect or the value of an image binary pixel of a...

Страница 49: ...data integrity and network security Please reboot the system for a change on this setting to take effect The options are Disable and Enable ACPI Settings ACPI Sleep State Use this feature to select wh...

Страница 50: ...ode Serial Port 2 Configuration Serial Port Select Enabled to enable the onboard serial port specified by the user The options are Disabled and Enabled Device Settings This item displays the base I O...

Страница 51: ...Select VT100 to add color and function key support Select ANSI to use the Extended ASCII Character Set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options...

Страница 52: ...support for ANSI VT100 terminals The options are Disabled and Enabled COM1 Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server The...

Страница 53: ...115200 bits per second COM2 Data Bits Use this feature to set the data transmission size for Console Redirection The options are 7 and 8 COM2 Parity A parity bit can be sent along with regular data b...

Страница 54: ...e this feature to enable or disable legacy Console Redirection after BIOS POST When set to Bootloader legacy Console Redirection is disabled before booting the OS When set to Always Enable legacy Cons...

Страница 55: ...f Data Bits Parity Stop Bits PCIe PCI PnP Configuration PCI Bus Driver Version A5 01 08 PCI Devices Common Settings Above 4G Decoding Select Enabled for 64 bit devices to be decoded above the 4GB addr...

Страница 56: ...Preboot Execution Environment for boot support If this feature is set to Disabled Ipv6 PXE boot option will not be supported The options are Disabled and Enabled PXE boot wait time Use this option to...

Страница 57: ...UEFI driver version Adapter PBA This item displays the Processor Bus Adapter PBA model number The PBA number is a nine digit number i e 010B00 000 located near the serial number Device Name This item...

Страница 58: ...linking the associated LED Use the keybaord to select a value 0 is the default UEFI Driver This item displays the UEFI driver version Adapter PBA This item displays the Processor Bus Adapter PBA model...

Страница 59: ...hen entering setup Select Always to require the password when entering setup and at each bootup The options are Setup and Always Setup Administrator Password Use this feature to set the administrator...

Страница 60: ...Key Management This submenu allows the user to configure the following Key Management settings Provision Factory Default Keys Select Enabled to install the default Secure Boot keys set by the manufac...

Страница 61: ...m the manufacturer s defaults to the existing DB Select No to load the DB from a file The options are Yes and No Forbidden Signatures Set New Var Select Yes to load the DBX from the manufacturer s def...

Страница 62: ...n d EFI SERT SHA256 bin 2 EFI Time Based Authenticated Variable When prompted select Yes to load Factory Defaults or No to load from a file Set New Var Select Yes to load the DBR from the manufacturer...

Страница 63: ...boot mode The options are LEGACY UEFI and DUAL Fixed Boot Order Priorities This option prioritizes the order of bootable devices that the system can boot from Press Enter on each entry from top to bo...

Страница 64: ...boot devices UEFI Boot Option 1 UEFI NETWORK Drive BBS Priorities This feature allows the user to specify which UEFI network drive devices are boot devices Legacy Boot Option 1 Legacy Boot Option 2 De...

Страница 65: ...ter Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset When you have completed the system configuration changes select this option to save all changes made and r...

Страница 66: ...user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Exit menu and press Enter Use this feature to retrieve user de...

Страница 67: ...ir corresponding beep codes encountered by users BIOS Beep POST Codes Beep Code Error Message Description 1 beep Refresh Circuits have been reset Ready to power up 5 short 1 long Memory error No memor...

Страница 68: ...r assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These...

Страница 69: ...o considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar...

Страница 70: ...dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het...

Страница 71: ...limentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het...

Страница 72: ...es del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 12VDC 3A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l install...

Страница 73: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 74: ...ls aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Warnu...

Страница 75: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 76: ...una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s un...

Страница 77: ...mblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorr...

Страница 78: ...s ontploffingsgevaar indien de batterij verkeerd vervangen wordt Vervang de batterij slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen wordt Gebruikte batterijen dienen ove...

Страница 79: ...lacion del equipo debe cumplir con las normas de electricidad locales y nacionales Attention L quipement doit tre install conform ment aux normes lectriques nationales et locales Warning Installation...

Страница 80: ...al of this product should be handled according to all national laws and regulations Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales Attenti...

Страница 81: ...para los cables que se utilicen y tendr n que sujetar tanto el aislante como el conductor Attention Quand des fils torsad s sont n cessaires utiliser des douilles terminales homologu es telles que cel...

Страница 82: ...unten zoals het gesloten lus type of het grijperschop type waarbij de aansluitpunten omhoog wijzen Deze aansluitpunten dienen de juiste maat voor de draden te hebben en dienen zowel de isolatie als de...

Страница 83: ...F Attention Avant de pratiquer l une quelconque des proc dures ci dessous v rifier que le circuit en courant continu n est plus sous tension Waarshuwing Wanneer geslagen bedrading vereist is dient u b...

Страница 84: ...sind Stellen Sie bei Benutzung der Abdeckung sicher dass alle nicht isolierten stromf hrenden Kabel abgedeckt sind Advertencia Puede haber energ a o voltaje peligrosos en los terminales el ctricos de...

Страница 85: ...DC aansluitingspunten kunnen zich gevaarlijke voltages of energie n voordoen Plaats altijd de afsluiting wanneer de aansluitingspunten niet worden gebruikt Zorg ervoor dat blootliggende contactpunten...

Страница 86: ...emperature 40 C to 70 C 40 F to 158 F Operating Relative Humidity 8 to 90 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Clas...

Страница 87: ...arnings 87 Appendix D Traditional Chinese Safety Warnings A 1 Traditional Chinese Version Safety Warnings Additional Traditional Chinese Version warning statements are included here in this appendix W...

Страница 88: ...88 SuperServer E50 9AP User s Manual A 2 Traditional Chinese Version Safety Warnings 1 2 3 4 5 1 2 3 4 1 2 1 2 3 4...

Страница 89: ...ion of the Restricted Substances Marking Equipment name Type designation Type Restricted substances and its chemical symbols Note 1 Exceeding 0 1 wt and exceeding 0 01 wt indicate that the percentage...

Страница 90: ...in BIOS image The boot block contains critical BIOS codes including memory detection and recovery codes for the user to flash a new BIOS image if the original main BIOS image is corrupted When the sys...

Страница 91: ...covery using a USB attached device follow the instructions below 1 Using a different machine copy the Super ROM binary image file into the disc Root directory of a USB device or a writable CD DVD Note...

Страница 92: ...te At this point you may decide if you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 5 When the screen as shown above displays use the arrow k...

Страница 93: ...Do not interrupt the BIOS flashing process until it has completed 8 Press Del continuously during system boot to enter the BIOS setup utility From the top of the tool bar click on Boot and press Enter...

Страница 94: ...rrupt this process until the BIOS flashing is complete 10 The screen above indicates that the BIOS update process is completed When you see the screen above unplug the AC power cable from the power su...