39
Chapter 2: Maintenance and Component Installation
3. Place the air shroud. The small rectangular portion covers the DIMMA1/DIMMB1/
DIMMC1 memory modules.
4. Replace the chassis cross bracket.
Checking the Server Air Flow
•
Make sure there are no objects to obstruct airflow in and out of the server.
•
Do not operate the server without drives or drive carriers in the drive bays.
•
Use only recommended server parts.
•
Make sure no wires or foreign objects obstruct air flow through the chassis. Pull all excess
cabling out of the airflow path or use shorter cables.
The control panel LEDs display system heat status. See “Control Panel” in Chapter 1 for
details.
Overheating
There are several possible responses if the system overheats.
•
Use the LEDs to determine the nature of the overheating condition.
•
Confirm that the chassis covers are installed properly.
•
Make sure all fans are present and operating normally.
•
Check the routing of the cables.
•
Verify that the heatsinks are installed properly.
Expansion Cards
The system supports up to three PCIe cards on a riser card: One PCIe 3.0 x16 slot and two
PCIe 3.0 x8 slots, OR two PCIe 3.0 x16 slots. Use the jumper on the riser card, JSEL1, to
configure.
Riser Card Jumper, JSEL1
Jumper
Setting
Slot1
Slot2
Slot3
1-2
x16
N/A
x16
2-3 (default)
x8
x8
x16
The system supports full height or low profile expansion cards, although you must modify the
air shroud when using full height.