UEFI USB Key Drive BBS Priorities

This feature is displayed when a storage media is detected.

UEFI Network Drive BBS Priorities

• 

Boot Option # - This feature sets the system boot order of detected devices. The options 
are 

[the list of detected boot device(s)] 

and Disabled. 

Add New Boot Option

This feature is displayed when a storage media is detected.

Delete Boot Option

Use this item to select a boot device to delete from the boot priority list.

Delete Boot Option

Select the target boot device to delete.

Содержание SuperServer E302-9A

Страница 1: ...USER S MANUAL Revision 1 0a SuperServer E302 9A ...

Страница 2: ...environment or residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful interference with radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case you will be required to correct the interfe...

Страница 3: ...ro com about policies safety_information cfm If you have any questions please contact our support team at support supermicro com This manual may be periodically updated without notice Please check the Supermicro website http www supermicro com for possible updates to the manual revision level Secure Data Deletion A secure data deletion tool designed to fully erase all data from storage devices can...

Страница 4: ... Choosing a Setup Location 16 Rack Precautions 16 Server Precautions 17 Rack Mounting Considerations 17 Ambient Operating Temperature 17 Airflow 17 Mechanical Loading 18 Circuit Overloading 18 Reliable Ground 18 Adding Components to your System 19 2 3 Mounting on a Wall 20 Chapter 3 Maintenance and Component Installation 3 1 Removing Power 23 3 2 Accessing the System 24 3 3 Motherboard Components ...

Страница 5: ...rs 42 4 6 LED Indicators 45 Chapter 5 Software 5 1 Microsoft Windows OS Installation 46 5 2 Driver Installation 48 5 3 SuperDoctor 5 49 5 4 IPMI 50 Chapter 6 UEFI BIOS 6 1 Introduction 51 Starting the Setup Utility 51 6 2 Main Menu 52 6 3 Advanced Settings Menu 53 6 4 Event Logs 77 6 5 IPMI 79 6 6 Security 82 6 7 Boot 85 6 8 Save Exit 87 Appendix A BIOS POST Codes Appendix B Standardized Warning S...

Страница 6: ...ddress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Website www supermicro nl Asia Pacific Address Super Micro Computer Inc 3F No 150 Jian 1st Rd Zhonghe Dist New Taipei City 235 Taiwan R O C Tel 886...

Страница 7: ...atures In addition to the motherboard and chassis several important parts that are included with the system are listed below Main Parts List Description Part Number Quantity 12V 60W DC Power Adapter MCP 250 10134 0N 1 Wall Mount Kit MCP 290 30201 0B Optional Cable CBL SAST 1034 Optional Cable CBL 0483L Optional Note the following safety models associated with the E302 9A have been certified as com...

Страница 8: ...speed Expansion Slots One 1 PCI Express 3 0 x4 Slot only supports Networking card with maximum 2x SSD not occupied One 1 M 2 PCI Express 3 0 x2 Slot Storage Drives Supports two 2 5 drives of 7mm height or one 2 5 of 15mm height Power Supply 60W DC Power Adapter Input Output Ports One dedicated IPMI One VGA Two 2 USB 2 0 ports on the rear I O panel USB0 1 Four 1GbE Cooling Fanless Dimensions 11 6 W...

Страница 9: ...Panel Features Item Features Description 1 Power button The main power switch applies or removes primary power from the power supply to the server but maintains standby power To perform most maintenance tasks unplug the system to remove all power 2 Power LED HDD LED Indicates power is being supplied to the system power supply units This LED is illuminated when the system is operating normally Indi...

Страница 10: ... power switch applies or removes primary power from the power supply to the server but maintains standby power To perform most maintenance tasks unplug the system to remove all power 2 I O ports IPMI LAN USB LAN and VGA described in Chapter 4 3 PCI window Standard low profile PCI E slot optional may add fan to front I O plate 4 K slot for lock Accepts a standard Kensington cable locking device not...

Страница 11: ...ter 1 Introduction Figure 1 4 Chassis Dimensions I O View Figure 1 3 Chassis Dimensions Top View Chassis Dimensions The compact chassis measures 295 x 206 mm from the top view and 295 x 76 mm from the I O view ...

Страница 12: ... FIT JSAS2 JMD1 JB3 LED1 JD1 JSMB1 JGP1 1 JBT1 JPH1 JPV1 FANA FAN1 FAN2 JF1 JTPM1 JL1 JRT4 JRT3 I SATA2 I SATA1 I SATA3 I SATA0 JUSB3A1 UIDLED1 A LEDM1 FANA FAN3 SUPERDOM SATA DOM POWER 8 11 4 7 I SATA I SATA IPMI LAN DIMMA1 DIMMA2 DIMMB2 DIMMB1 CPU ALWAYS POPULATE DIMMA1 FIRST CPU SLOT7 PCI E 3 0 X4 M 2 PCI E 3 0 X2 I SATA LAN4 INTRUSION JD1 1 4 SPEAKER CHASSIS JL1 JPB1 BMC 1 2 ENABLE 2 3 DISABLE...

Страница 13: ...cated IPMI LAN Port I SATA0 I SATA3 Intel SATA 3 0 Ports I SATA0 supports SuperDOM JD1 Speaker Header JF1 Front Control Panel Header JGP1 General Purpose I O Header JL1 Chassis Intrusion Header JMD1 M 2 PCI E 3 0 x2 I SATA Slot Not available on 2C model JPH1 4 pin Power Connector for HDD use To provide power from the motherboard to onboard HDD devices JPI2 C1 Power Supply SMBbus I2 C Header JPV1 4...

Страница 14: ...nector Description SLOT7 CPU PCI E 3 0 x4 Slot SRW1 SRW2 M 2 Holding Screws UID Unit ID Button USB0 1 Back Panel Universal Serial Bus USB 2 0 Ports USB2 3 Front Accessible USB 2 0 Header USB4 Front Accessible USB 3 0 Type A Port VGA VGA Port ...

Страница 15: ...E1543 1G BaseT SGMII AST2400 COM1 HEADER TPM1 2 Header LPC HSIO 14 PCIEX1 LAN 0 LAN 1 SVID VR13 VGA 6Gb s SATA PCIE SSD SATA III M 2 2280 2242 PCIe 3 0_x2 8GT s PCIE SLOT X4 PCIe 3 0_x4 8GT s HSIO 3 0 PCIEX4 HSIO 13 12 SATA PCIEX2 HSIO 18 15 SATA III 6Gb s 4 X SATA III PORT SATA III 6Gb s mini SAS CONNX2 HSIO 11 4 SATA PORT11 4 RJ45 RTL8211F RGMII2 GIGALAN SGPIO 1 0 8 X SATA III 1 X USB3 0 Type A ...

Страница 16: ...on in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated Leave at least 25 inches of clearance in front of the rack so that you can open the front door completely Leave approximately 30 inches of clearance behind the ...

Страница 17: ...eight with the lightest component at the top Use a regulating uninterruptible power supply UPS to protect the server from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep the front door of the rack and all covers and panels closed to maintain proper cool...

Страница 18: ...s They are designed to pull the system from a rack only Mounted equipment is not to be used as a shelf or a work space Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possi...

Страница 19: ...o Chapter 3 for details on compatible types of memory and the installation procedure Drives and Storage To add storage capabilities to your server see Chapter 3 Input Output See Chapter 4 for I O ports and connect them as needed Software See Chapter 5 for description and procedures for installing software including drivers and monitoring programs ...

Страница 20: ... 0B 1 Secure the bracket to the wall where you want the server to be mounted by using four screws through the holes around the center of the bracket as shown below 2 Flip the tab of the latch on the top of the chassis bracket to unlock the latch then slide the latch upward Chassis Bracket Latch Locking Tab of Chassis Bracket Latch Bracket Screws Figure 2 2 Chassis Bracket Latch ...

Страница 21: ...n additional bracket for a power adapter can be attached to the bottom of the chassis bracket with a screw as pictured below 3 With the input output ports facing up hang the server on the mounting bracket by hooking the four keyholes on the bottom of the chassis on the four knobs of the bracket Figure 2 4 Chassis Bracket with Power Adapter Bracket Attached Power Adapter Bracket Screw ...

Страница 22: ...s lower bracket by partially unscrewing its latch sliding the latch upward placing the power adapter in the bracket lowering the latch and tightening the screw to secure it in place Figure 2 5 Power Adapter Bracket Power Adapter Bracket Latch Screw of Power Adapter Bracket Latch ...

Страница 23: ...mponents require that power first be removed from the system Please follow the procedures given in each section 3 1 Removing Power Use the following procedure to ensure that power has been removed from the system This step is necessary when removing or installing non hot swap components or when replacing a non redundant power supply 1 Use the operating system to power down the system 2 After the s...

Страница 24: ...wer down the system as described in section 3 1 2 Remove the six screws that hold the cover in place 3 Lift the cover up and off the chassis Caution Except for short periods of time do not operate the server without the cover in place The chassis cover must be in place to allow proper airflow and prevent overheating Figure 3 1 Removing the Chassis Cover Screws Screws ...

Страница 25: ...up to 2400MHz in four memory slots Populating these DIMM slots with memory modules of the same type and size will result in interleaved memory which will improve memory performance Note Check the Supermicro website for recommended memory modules DIMM Module Population Configuration For optimal memory performance follow the table below when populating memory Memory Population Balanced DIMMA1 DIMMB1...

Страница 26: ...C 1 2 ENABLE 2 3 DISABLE 1 2 ENABLE JI2C1 2 3 DISABLE JI2C2 1 2 ENABLE 2 3 DISABLE 1 2 NORMAL JPME2 2 3 ME MANUFACTURING MODE RST JF1 ON PWR 2 NIC OH FF X 2 3 NMI 1 2 RST JWD1 WATCH DOG PWR 1 LED HDD NIC LED JPI2C1 JBR1 1 2 NORMAL 2 3 BIOS RECOVERY LAN2 USB0 1 USB2 3 USB4 3 0 VGA LAN1 LAN3 BT1 DIMM Module Population Sequence When installing memory modules the DIMM slots should be populated in the ...

Страница 27: ... 3 NMI 1 2 RST JWD1 WATCH DOG PWR 1 LED HDD NIC LED JPI2C1 JBR1 1 2 NORMAL 2 3 BIOS RECOVERY LAN2 USB0 1 USB2 3 USB4 3 0 VGA LAN1 LAN3 BT1 DIMM Installation 1 Insert DIMM modules in the following order DIMMA1 DIMMB1 then DIMMA2 DIMMB2 For the system to work properly please use memory modules of the same type and speed 2 Push the release tabs outwards on both ends of the DIMM slot to unlock it 3 Al...

Страница 28: ... with the positive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully Do not damage the battery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by your local hazardous waste management agency to di...

Страница 29: ...tallation 3 4 Chassis Components Installing the Storage Drive The E302iL can accommodate two 2 5 drives of 7mm height or one 2 5 drive of 15mm height installed to a mounting tray inside the chassis Figure 3 4 Preparing to Install the Hard Drive ...

Страница 30: ... section 3 2 for instructions on how to remove the top cover 3 Lift the hard drive tray from the chassis as shown in Figure 3 4 4 Place one 7mm 2 5 drives directly into the tray and secure it to the tray with the standoff plugs on the sides of the tray 5 Optionally for 7 mm 2 5 drives slide them inside the tray first then secure them to the drive tray with the standoff plugs as shown above Figure ...

Страница 31: ...the drive data and power cables 7 Secure the tray to the chassis by pushing the tray down into the slots 8 Attach the cables to the appropriate motherboard connector s 9 Reinstall the chassis cover and power up the system Figure 3 6 Installing 7 mm 2 5 Hard Drives ...

Страница 32: ...s Pin Definition Pin Definition 13 3 3V 1 3 3V 14 12V 2 3 3V 15 COM 3 COM 16 PS_ON 4 5V 17 COM 5 COM 18 COM 6 5V 19 COM 7 COM 20 Res NC 8 PWR_OK 21 5V 9 5VSB 22 5V 10 12V 23 5V 11 12V 24 COM 12 3 3V Required Connection 4 pin HDD Power Pin Definitions Pin Definition 1 12V 2 3 Ground 4 5V 12V 4 pin Power Pin Definitions Pin Definition 1 2 Ground 3 4 12V 1 1 4 4 2 3 JPH1 JPV1 BIOS LICENSE JTGLED1 JPW...

Страница 33: ...1 JRT4 JRT3 I SATA2 I SATA1 I SATA3 I SATA0 JUSB3A1 UIDLED1 A LEDM1 FANA FAN3 SUPERDOM SATA DOM POWER 8 11 4 7 I SATA I SATA IPMI LAN DIMMA1 DIMMA2 DIMMB2 DIMMB1 CPU ALWAYS POPULATE DIMMA1 FIRST CPU SLOT7 PCI E 3 0 X4 M 2 PCI E 3 0 X2 I SATA LAN4 INTRUSION JD1 1 4 SPEAKER CHASSIS JL1 JPB1 BMC 1 2 ENABLE 2 3 DISABLE 1 2 ENABLE JI2C1 2 3 DISABLE JI2C2 1 2 ENABLE 2 3 DISABLE 1 2 NORMAL JPME2 2 3 ME M...

Страница 34: ...anel USB 2 0 Header Pin Definitions Pin Definition Pin Definition 1 5V 2 5V 3 USB_PN2 4 USB_PN3 5 USB_PP2 6 USB_PP3 7 Ground 8 Ground 9 Key 10 Ground Universal Serial Bus USB Ports There are two USB ports USB0 1 on the I O back panel The motherboard also has one front access USB 2 0 header USB2 3 and one USB 3 0 Type A header USB4 The onboard headers can be used to provide front side USB access wi...

Страница 35: ...Di 2C HLN4F REV 1 00 DESIGNED IN USA BAR CODE COM1 JPCIE1 JSD1 1 SRW1 SRW2 JUIDB JPL1 JWD1 JPG1 JBR1 JPME2 JI2C1 JI2C2 PRESS FIT JSAS1 PRESS FIT JSAS2 JMD1 JB3 LED1 JD1 JSMB1 JGP1 1 JBT1 JPH1 JPV1 FANA FAN1 FAN2 JF1 JTPM1 JL1 JRT4 JRT3 I SATA2 I SATA1 I SATA3 I SATA0 JUSB3A1 UIDLED1 A LEDM1 FANA FAN3 SUPERDOM SATA DOM POWER 8 11 4 7 I SATA I SATA IPMI LAN DIMMA1 DIMMA2 DIMMB2 DIMMB1 CPU ALWAYS POP...

Страница 36: ...n The Power Button connection is located on pins 1 and 2 of JF1 Momentarily contacting both pins will power on off the system This button can also be configured to function as a suspend button with a setting in the BIOS see Chapter 4 To turn off the power in the suspend mode press the button for at least 4 seconds Refer to the table below for pin definitions Reset Button The Reset Button connectio...

Страница 37: ... Fail Indicator Status Pin Definition Off Normal On Overheat Flashing Fan Fail NIC1 NIC2 LAN1 LAN2 The NIC Network Interface Controller LED connection for LAN port 1 is located on pins 11 and 12 of JF1 and the LED connection for LAN Port 2 is on pins 9 and 10 NIC1 LED and NIC2 LED are 2 pin NIC LED headers Attach NIC LED cables to NIC1 and NIC2 LED indicators to display network activities Refer to...

Страница 38: ... Control Speaker JD1 is the speaker header Connect the cable of the external speaker to pins 1 4 Speaker Connector Pin Definitions Pin Definition Pins 1 4 Speaker General Purpose I O Header JGPIO1 is a 10 pin general purpose I O header located near the IPMI port Each pin can be configured to be an input or output pin The GPIO is controlled via the PCA9554 8 bit GPIO expansion The base address is 0...

Страница 39: ... Refer the table below for pin definitions Note Please go to the following link for information on TPM http www supermicro com manuals other TPM pdf 1 2 20 19 JTGLED1 JPW1 DESIGNED IN USA LED1 JBT1 JPH1 JPV1 FANA FAN1 FAN2 JF1 JTPM1 JRT4 JRT3 FAN3 CPU RST JF1 ON PWR 2 NIC OH FF X PWR 1 LED HDD NIC LED BT1 Disk On Module Power Connector The Disk On Module DOM power connector at JSD1 provides 5V pow...

Страница 40: ...ave devices or sensors is located at JSMB1 Refer to the table below for pin definitions LAN Port Activity LED Headers JTGLED1 is the activity header for LAN3 and LAN4 LAN Activity LED Pin Definitions Pin Definition 1 3V3 Stby 2 LAN3_ACT_N 3 3V3 Stby 4 LAN4_ACT_N Thermal Diode Headers JRT3 is the thermal diode 1 header and JRT4 is the thermal diode 2 header They are thermal sensor headers that prov...

Страница 41: ... motherboard The UID switch is located at UID which is next to the VGA port on the back panel The UID LED UIDLED1 is located next to the UID switch When you press the UID switch the UID LED will be turned on Press the UID switch again to turn off the LED indicator The UID Indicator provides easy identification of a system unit that may be in need of service Note UID can also be triggered via IPMI ...

Страница 42: ... Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To Clear CMOS 1 First power down the system and unplug the power cord s 2 Remove the cover of the chassis to access the motherboard 3 Remove the onboard battery from the mother...

Страница 43: ...s 2 3 Manufacturing Mode BIOS Recovery Use jumper JBR1 to recover the BIOS settings The default setting is Normal See the table below for jumper settings BIOS Recovery Jumper Settings Jumper Setting Definition Pins 1 2 Normal Default Pins 2 3 BIOS Recovery Watch Dog JWD1 controls the Watch Dog function Watch Dog is a monitor that can reboot the system when a software application hangs Jumping pins...

Страница 44: ...bled SMBus to PCI Slots Jumpers JI2 C1 and JI2 C2 allow you to connect the System Management Bus I2 C to the PCI E slots Both jumpers must be set to the same setting JI2 C1 controls the clock and JI2 C2 controls the data The default setting is Disabled SMBus to PCI Slots Jumper Settings JI2 C1 Setting JI2 C2 Setting Definition JI2 C1 Pins 1 2 JI2 C2 Pins 1 2 Enabled JI2 C1 Pins 2 3 JI2 C2 Pins 2 3...

Страница 45: ... Activity LED Link LED LAN 1 LAN 2 IPMI LAN X8ST3 F Link LED Indicator LED Color Definition Off No Connection or 10 Mb s Green 100 Mb s Amber 1 Gb s Activity Indicator Color Status Definition Off No Connection Yellow Flashing Active Activity LED Link LED Onboard Power LED LED1 is an Onboard Power LED When this LED is lit it means power is present on the motherboard In suspend mode this LED will bl...

Страница 46: ... at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash drive or the IPMI KVM console 2 Retrieve the proper RST RSTe driver Go to the Supermicro web page for your motherboard and click on Download the Latest Drivers and Utilities select the proper driver...

Страница 47: ...river browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the SATA sSATA AHCI driver indicated then choose the storage drive on which you want to install it 5 Once all devices are specified continue with the installation 6 After the Windows OS installation has c...

Страница 48: ...ferred Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive or disk and the screenshot shown below should appear Figure 5 3 Driver Tool Installation Screen Note Click the icons showing a hand writing on paper to view the readme files for each item Click t...

Страница 49: ...you can remotely control the power status and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SD5 Management Server monitors HTTP FTP and SMTP services to optimize the efficiency of your operation Note The default username and password for SuperDoctor 5 is ADMIN ADMIN Figure 5 4 SuperDoctor 5 Interface Display Screen Health Information Note 2 When making a storage driver di...

Страница 50: ...te access monitoring and management There are several BIOS settings that are related to IPMI Supermicro ships standard products with a unique password for the BMC ADMIN user This password can be found on a label on the motherboard For general documentation and information on IPMI please visit our website at http www supermicro com products nfo IPMI cfm ...

Страница 51: ...as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often a text mes...

Страница 52: ... Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 The date s default value is the BIOS build date after RTC reset Supermicro A2SDi 4C HLN4F BIOS Version This item displays the version of the BIOS ROM used in the system Build ...

Страница 53: ...manufacturer settings Boot Feature Quiet Boot Use this feature to select the screen display between POST messages or the OEM logo at bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST messages The options are Disabled and Enabled Bootup NumLock State Use this feature to set the Power on state for the Numlock key The options are Off...

Страница 54: ... the power state after a power outage Select Power Off for the system power to remain off after a power loss Select Power On for the system power to be turned on after a power loss Select Last State to allow the system to resume its last power state before a power loss The options are Stay Off Power On and Last State CPU Configuration The following CPU information will display Displays the CPU mod...

Страница 55: ...t Eanbled to enhance the Cx state of the CPU Reboot the system for this feature to take effect The options are Disable and Enable Package C State limit Use this item to set the limit on the C State package register The options are No Pkg C State No S0Ix and No Limit The feature above is not available when CPU C State is disabled Max Core C State Use this feature to select the CPU C state The optio...

Страница 56: ...ow the processor to designate areas in the system memory where an application code can execute and where it cannot thus preventing a worm or a virus from flooding illegal codes to overwhelm the processor or damaging the system during a virus attack The options are Disable and Enable Refer to Intel and Microsoft websites for more information Virtualization Technology Select Enable to use Intel Virt...

Страница 57: ...ach CPU Select 0 to activate all processor cores Chipset Configuration Warning Setting the wrong values in the following sections may cause the system to malfunc tion North Bridge Configuration North Bridge Configuration Memory Information MRC Version Total Memory Memory Frequency VT d Select Enabled to enable Intel Virtualization Technology support for Direct I O VT d by reporting the I O device ...

Страница 58: ...feature to select whether the ADR State source is internal or external The op tions are external and internal Internal Pwr Loss Event Setup SoC Pwr Loss Support The feature is always Disabled PMC Reset Enable this feature to receive a notification when there is a global reset because of an SMBus slave power down The options are Disabled and Enabled Power Button Override When this feature is set to...

Страница 59: ...t power to system components is stable The options are Disabled and Enabled PMC Parity Error Set this feature to Enabled to receive PMC parity error notifications The options are Disabled and Enabled Return Power Set this feature to Enabled for the system to power up within four seconds after an ADR entry The options are Disabled and Enabled Interleaving Set this feature to Enabled for NVDIMM inte...

Страница 60: ...ze BMBOUND Base Use this feature to select the memory mapped IO size and BMBOUND base setting The low for the two settings will always be 4GB The options are Auto 1024M 3072M and 3072M 1024M TCL Performance Use this feature to enable the CAS Latency tCL to increase memory performance The options are Disabled and Enabled Memory Preservation Enable this feature for the memory content to be preserved...

Страница 61: ... the memory refresh rate The options are 1x 2x and 1x 2x 4x CKE Power Down Clock enable CKE Power Down controls the low power down for the memory The options are Disabled Active Power Down and Precharge Power Down Memory Thermal Throttling Memory thermal throttling is a power management feature that monitors read and write activities to control power consumption The options are Auto and Disabled I...

Страница 62: ...ort 60h 64h emulation support which in turn will provide complete legacy USB keyboard support for the operating systems that do not support legacy USB devices The options are Disabled and Enabled The following two options are displayed if they are detected by and available on the system Flexible I O Selection This is a feature on the 2C 4C models only Up to a total of 8 in selected combinations of...

Страница 63: ...e to enable or disable Aggressive Link Power Management The options are Enabled and Disabled SATA 0 SGPIO LED Use this feature to select SATA SGPIO or SATA LED The options are SATA SGPIO and SATA LED I SATA4 I SATA11 This following information is displayed for each SATA drive entry Device Information Device Size Enable disable port Use this feature to disable or enable the SATA port number The opt...

Страница 64: ...to enable or disable Aggressive Link Power Management The options are Enabled and Disabled SATA 1 SGPIO LED Use this feature to select SATA SGPIO or SATA LED The options are SATA SGPIO and SATA LED I SATA0 I SATA3 I SATA M 2 This following information is displayed for each SATA drive entry Device Information Device Size Enable disable port Use this feature to disable or enable the SATA port number...

Страница 65: ...4 bit in the space above 4G Address The options are Enabled and Disabled SR IOV Support Available if the system supports Single Root Virtualization Select Enabled for Single Root IO Virtualization SR IOV support SR IOV is an extension of the PCI Express interface and consists of two functions physical functions PF and virtual functions VF PF is the primary function and is used to control and confi...

Страница 66: ...ly below the port The options are Disabled and Enabled CPU SLOT7 PCI E 3 0 X4 OPROM Use this item to select the firmware type for the add on card for this slot The options are Disabled Legacy and EFI M 2 PCI E 3 0 X2 OPROM Use this item to select the firmware type for the add on card for this slot The options are Disabled Legacy and EFI Onboard LAN Option ROM Type Use this item to select the Onboa...

Страница 67: ... This item displays the base I O port address and the Interrupt Request address of a serial port specified by the user Note This item is hidden when Serial Port 1 is set to Disabled Serial Port 1 Change Settings This feature specifies the base I O port address and the Interrupt Request address of Serial Port 1 Select Auto for the BIOS to automatically assign the base I O and IRQ address to a seria...

Страница 68: ...OM1 Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits is odd Select None if you do not want to send a parity bit with your data bits in transmission Select Mark to add a mark as a parity bit to...

Страница 69: ...feature to specify how the host computer will exchange data with the client computer which is the remote computer used by the user SOL Terminal Type Use this feature to select the target terminal emulation type for Console Redirection Select VT100 to use the ASCII Character set Select VT100 to add color and function key support Select ANSI to use the Extended ASCII Character Set Select VT UTF8 to ...

Страница 70: ...g data when the receiving buffer is full Send a Start signal to start sending data when the receiving buffer is empty The options are None and Hardware RTS CTS SOL VT UTF8 Combo Key Support Select Enabled to enable VT UTF8 Combination Key support for ANSI VT100 terminals The options are Disabled and Enabled SOL Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as...

Страница 71: ...re that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 57600 and 115200 bits per second Flow Control Use this item to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full S...

Страница 72: ...s installed and detected by the BIOS The features from here to Current Status Information are displayed if a TPM module is detected Security Device Support If this feature and the TPM jumper on the motherboard are both set to Enabled onboard security devices will be enabled for TPM support to enhance data integrity and network security Please reboot the system for a change on this setting to take ...

Страница 73: ...re and the TPM jumper on the motherboard are both set to Enabled onboard security devices will be enabled for TPM support to enhance data integrity and network security Please reboot the system for a change on this setting to take effect The options are Disable and Enable The following TPM information will be displayed Active PCR banks Available PCR banks If the feature Security Device Support is ...

Страница 74: ...e Disabled and Enabled Endorsement Hierarchy Use this item to disable or enable endorsement hierarchy for privacy control The options are Disabled and Enabled TPM2 0 UEFI Spec Version Use this feature to specify the TPM UEFI spec version TCG 1 2 has support for Windows 2012 Windows 8 and Windows 10 TCG 2 has support for Windows 10 or later The options are TCG_1_2 and TCG_2 Physical Presence Spec V...

Страница 75: ...These items display the following information NIC Configuration Link Speed Use this feature to change the link speed and duplex for the current port The options are Auto Negotiated 10Mbps Half 10Mbps Full 100Mbps Half and 100Mbps full Wake On LAN Select enabled to wake the system with a magic packet The options are Enabled and Disabled Blink LEDs This feature allows the user to specify the duratio...

Страница 76: ...e PCI address for this computer PCI addresses are three two digit hexadecimal numbers Link Status This item displays the connection status MAC Address This item displays the MAC address for this computer Mac addresses are six two digit hexadecimal numbers Virtual MAC Address This item displays the Virtual MAC address for this computer Mac addresses are six two digit hexadecimal numbers ...

Страница 77: ...Support Use this feature to enable or disable memory error logging suport The options are Disabled and Enabled SMBIOS Event Log Change this item to enable or disable all features of the SMBIOS Event Logging during system boot The options are Enabled and Disabled Erasing Settings Erase Event Log Select Enabled to erase all error events in the SMBIOS System Management BIOS log before an event loggin...

Страница 78: ...nabled and Disabled MECI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This item is used to determine how long in minutes should the multiple event counter wait before generating a new event log Enter a number between 0 to 99 The default setting is 60 Note Please...

Страница 79: ...alled in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Disabled and Enabled Erasing Settings Erase SEL Select Yes On next reset to erase all system event logs upon next system reboot Select Yes On every reset to erase all system event logs upon each system reboot Select No to keep all system event logs a...

Страница 80: ...and VLAN will become available for configuration Configuration Address Source Use this item to select the source of the IP address for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually in the field If DHCP is selected the BIOS will search for a DHCP Dynamic Host Configuration Protocol server in the network that is attached...

Страница 81: ... Function Support Use this feature to enable IPMI support The options are Enabled and Disabled When disabled the system powers on quicker by removing BIOS support for extended IPMI features The Disable option is for applications that require faster power on time wthout using Supermicro Update Manager SUM or extended IPMI features The BMC network configuration in the BIOS setup is also invalid when...

Страница 82: ...nd Always Administrator Password Use this feature to set the administrator password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long The feature below is displayed if an Administrator Password is set User Password Use this feature to set a user password Secure Boot Platform Mode Setup Secure Boot Not Active Vendor Keys N...

Страница 83: ...ettings Provision Factory Defaults Select Enabled to install the default Secure Boot keys set by the manufacturer The options are Disabled and Enabled Install Factory Default Keys Select Yes to install the default settings for all keys The options are Yes and No Enroll Efi Image This feature allows the image to run in Secure Boot mode Save All Secure Boot Variables This feature allows the user to ...

Страница 84: ... Append Select Yes to add the DBX from the manufacturer s defaults to the existing DBX Select No to load the DBX from a file The options are Yes and No Authorized TimeStamps Set New Select Yes to load the DBT from the manufacturer s defaults Select No to load the DBT from a file The options are Yes and No Append Select Yes to add the DBT from the manufacturer s defaults list to the existing DBT Se...

Страница 85: ...ter on each entry from top to bottom to select devices UEFI Boot Option 1 UEFI Boot Option 2 UEFI Boot Option 3 UEFI Boot Option 4 UEFI Boot Option 5 UEFI Boot Option 6 UEFI Boot Option 7 UEFI Boot Option 8 UEFI Boot Option 9 UEFI Application Boot Priorities Boot Option This feature sets the system boot order of detected devices The options are the list of detected boot device s and Disabled ...

Страница 86: ...oot Option This feature sets the system boot order of detected devices The options are the list of detected boot device s and Disabled Add New Boot Option This feature is displayed when a storage media is detected Delete Boot Option Use this item to select a boot device to delete from the boot priority list Delete Boot Option Select the target boot device to delete ...

Страница 87: ...ystem configuration and reboot the computer Select Discard Changes and Exit from the Exit menu and press Enter Save Changes When you have completed the system configuration changes select this option to save all changes made This will not reset reboot the system Discard Changes Select this option and press Enter to discard all the changes and return to the AMI BIOS Utility Program Default Options ...

Страница 88: ...ss Enter Use this feature to retrieve user defined settings that were saved previously Boot Override This feature allows the user to override the Boot Option Priorities sequence in the Boot menu and immediately boot the system with another device specified by the user This is a one time override UEFI Built in EFI Shell UEFI PXE IP4 Intel Ethernet Connection X553 1GbE UEFI PXE IP4 Intel Ethernet Co...

Страница 89: ...permicro com support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnostic card can be attached to the computer to read I O port 0080h Supermicro p n AOC LPC80 20 For information on AMI updates please refer to http www ami com products ...

Страница 90: ...figuring components in the Supermicro chassis These warnings may also be found on our website at http www supermicro com about policies safety_information cfm Warning Definition 警告の定義 この警告サインは危険を意味します 人身事故につながる可能性がありますので いずれの機器でも動作させる前に 電気回路に含まれる危険性に注意して 標準的な事故防止策に精通して下さい 此警告符号代表危险 您正处于可能受到严重伤害的工作环境中 在您使用设备开始工作之前 必须充分意识到触电 的危险 并熟练掌握防止事故发生的标准工作程序 请根据每项警告结尾的声明号码找到此设 备的安全性警告说明的翻译文本 此警告符號代表危險 您正處於可能身體...

Страница 91: ...rará el número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels Avant de travailler sur un équipement soyez conscient des dangers liés a...

Страница 92: ...n risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE INSTRUCTIES Installation Instructions Warning Read the installation instructions before connecting the system to the power source 設置手順書 システムを電源に接続する前に 設置手順書をお読み下さい 警告 将此系统连接电源前 请先阅读安装说...

Страница 93: ...에 설치 안내를 읽어주십시오 Waarschuwing Raadpleeg de installatie instructies voordat u het systeem op de voedingsbron aansluit サーキッ ト ブレーカー この製品は 短絡 過電流 保護装置がある建物での設置を前提としています 保護装置の定格が250 V 20 Aを超えないこ とを確認下さい 警告 此产品的短路 过载电流 保护由建筑物的供电系统提供 确保短路保护设备的额定电流不大于 250V 20A 警告 此產品的短路 過載電流 保護由建築物的供電系統提供 確保短路保護設備的額定電流不大於 250V 20A Warning This product relies on the building s installation for short circuit overcurrent pro...

Страница 94: ...rtension ce produit dépend de l installation électrique du local Vérifiez que le courant nominal du dispositif de protection n est pas supérieur à 250 V 20 A 경고 이 제품은 전원의 단락 과전류 방지에 대해서 전적으로 건물의 관련 설비에 의존합니다 보호장치의 정격이 반드시 250V 볼트 20A 암페어 를 초과하지 않도록 해야 합니다 Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging overspanning van uw electrische installatie Controleer of het beveiligde apa...

Страница 95: ...as fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le système doit être débranché de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d accéder à l intérieur du chassis pour installer ou enlever des composants de sys...

Страница 96: ...Warning Only trained and qualified personnel should be allowed to install replace or service this equipment 機器の設置 トレーニングを受け認定された人だけがこの装置の設置 交換 またはサービスを許可されていま す 警告 只有经过培训且具有资格的人员才能进行此设备的安装 更换和维修 警告 只有經過受訓且具資格人員才可安裝 更換與維修此設備 Warnung Das Installieren Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado de...

Страница 97: ...僅限安裝於進出管制區域 進出管制區域係指僅能以特殊工具 鎖頭及鑰匙或其他安全 方式才能進入的區域 Attention Il est vivement recommandé de confier l installation le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of securit...

Страница 98: ...cès réservés L accès à une zone d accès réservé n est possible qu en utilisant un outil spécial un mécanisme de verrouillage et une clé ou tout autre moyen de sécurité 경고 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다 특수도구 잠금 장치 및 키 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다 Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen verkreg...

Страница 99: ...manera incorrecta Reemplazar la batería exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante Desechar las baterías gastadas según las instrucciones del fabricante 電池の取り扱い 電池交換が正しく行われなかった場合 破裂の危険性があります 交換する電池はメーカーが推 奨する型 または同等のものを使用下さい 使用済電池は製造元の指示に従って処分して下さい 警告 电池更换不当会有爆炸危险 请只使用同类电池或制造商推荐的功能相当的电池更换原有电 池 请按制造商的说明处理废旧电池 警告 電池更換不當會有爆炸危險 請使用製造商建議之相同或功能相當的電池更換原有電池 請按 照製造商的說明指...

Страница 100: ... Supplies Warning This unit might have more than one power supply connection All connec tions must be removed to de energize the unit 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります ユニッ トの電源を切るためには すべての接続を取り外さなければなりません 警告 此部件连接的电源可能不止一个 必须将所有电源断开才能停止给该部件供电 警告 此裝置連接的電源可能不只一個 必須切斷所有電源才能停止對該裝置的供電 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugeführt w...

Страница 101: ...na conexión para fuentes de alimentación Para cortar por completo el suministro de energía deben desconectarse todas las conexiones Attention Cette unité peut avoir plus d une connexion d alimentation Pour supprimer toute tension et tout courant électrique de l unité toutes les connexions d alimentation doivent être débranchées אחד מספק יותר קיים אם אזהרה לרוקן מנת על החיבורים כל את להסיר יש ספק ש...

Страница 102: ...ht bei der Wartung Advertencia Cuando el sistema está en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le système est en fonctionnement des tensions électriques circulent sur le fond de panier Prendre des précautions lors de la maintenance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use cau...

Страница 103: ...kplane 에는 위험한 전압이나 에너지가 발생 합니다 서비스 작업 시 주의하십시오 Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden tijdens het onderhoud Attention L équipement doit être installé conformément aux normes électriques nationales et locales 警告 设备安装必须符合本地与本国电气法规 警告 設備安裝必須符合本地與本國電氣法規 Warning Installation of the equipment must comply w...

Страница 104: ...據所有國家的法律和規章進行 Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled according to all national laws and regulations Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales הארצי החשמל חוקי תיאום אזהרה והארציים המקומיים החשמל לחוקי תואמת ל...

Страница 105: ...arts Keep away from moving fan blades The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from the openings in the fan assembly s housing ファン ホッ トスワップの警告 警告 回転部品に注意 運転中は回転部 羽根 に触れないでく ださい シャーシから冷却ファン装 置を取り外した際 ファンがまだ回転している可能性があります ファンの開口部に 指 ドライバ ー およびその他のものを近づけないで下さい 警告 警告 危险的可移动性零件 请务必与转动的风扇叶片保持距离 当您从机架移除风扇装置 风扇可能仍在转动...

Страница 106: ...Prenez garde à ce que doigts tournevis et autres objets soient éloignés du logement du bloc ventilateur 경고 움직이는 위험한 부품 회전하는 송풍 날개에 접근하지 마세요 섀시로부터 팬 조립품을 제거할 때 팬은 여전히 회전하고 있을 수 있습니다 팬 조림품 외관의 열려있는 부분들로부터 손가락 및 스크류드라이버 다른 물체들이 가까이 하지 않도록 배치해 주십시오 Waarschuwing Gevaarlijk bewegende onderdelen Houd voldoende afstand tot de bewegende ventilatorbladen Het is mogelijk dat de ventilator nog draait tijdens ...

Страница 107: ...グと共に使用下さい 他のケー ブルやアダプタを使用すると故障や火災の原因になるこ とがあります 電気用品安全法は ULまたはCSA認定のケーブル UL CSAマークがコードに表記 を Supermicro が指定する製品以外に使用するこ とを禁止しています 警告 安装此产品时 请使用本身提供的或指定的或采购的连接线 电源线和电源适配器 包含遵照当 地法规和安全要求的合规的电源线尺寸和插头 使用其它线材或适配器可能会引起故障或火灾 除了Supermicro所指定的产品 电气用品和材料安全法律规定禁止 使用未经UL或CSA认证的线材 线材上会显示UL CSA符号 警告 安裝此產品時 請使用本身提供的或指定的或採購的連接線 電源線和電源適配器 包含遵照當 地法規和安全要求的合規的電源線尺寸和插頭 使用其它線材或適配器可能會引起故障或火災 除了Supermicro所指定的產品 電氣用品和材料安全法...

Страница 108: ...חשמל במכשירי השימוש לחוקי UL ב או CSA קוד עליהם מופיע כאשר של UL CSA ע י הותאם אשר במוצר רק אלא אחר חשמלי מוצר כל עבור Supermicro בלבד ذلك يف مبا املحلية السالمة ومتطلبات بقوانني ام ز االلت مع املرتدد التيار ومحوالت الكهربائية الكابالت اء رش ب قم أو املحددة أو املتوفرة التوصيالت باستخدام قم املنتج تركيب عند املعتمدة الكابالت استخدام واملعدات الكهربائية لألجهزة السالمة قانون يحظر حريق أو عطل يف يتس...

Страница 109: ...sluiten van het Product uitsluitend gebruik maken van de geleverde Kabels of een andere geschikte aan te schaffen Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storing of brand veroorzaken Wetgeving voor Elektrische apparatuur en Materiaalveiligheid ver...

Страница 110: ... consists of a recovery BIOS block and a main BIOS block a main BIOS image The boot block contains critical BIOS codes including memory detection and recovery codes for the user to flash a new BIOS image if the original main BIOS image is corrupted When the system power is on the boot block codes execute first Once it is completed the main BIOS code will continue with system initialization and boo...

Страница 111: ...SB attached device follow the instructions below 1 Using a different machine copy the Super ROM binary image file into the disc Root Directory of a USB device or a writeable CD DVD Note If you cannot locate the Super ROM file in your driver disk visit our website at www supermicro com to download the BIOS image into a USB flash device and rename it Super ROM for BIOS recovery use 2 Insert the USB ...

Страница 112: ... you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 5 When the screen as shown above displays use the arrow keys to select the item Proceed with flash update and press the Enter key You will see the BIOS recovery progress as shown in the screen below Note Do not interrupt the BIOS flashing process until it has completed ...

Страница 113: ... into a USB flash drive 8 Press Del continuously to enter the BIOS setup utility Set the item Boot Option 1 to UEFI AP UEFI Built in EFI Shell Press F4 to save the settings and exit the BIOS setup utility 6 After the BIOS recovery process is completed press any key to reboot the system ...

Страница 114: ...rrupt this process until the BIOS flashing is complete 10 The screen above indicates that the BIOS update process is completed When you see the screen above unplug the AC power cable from the power supply clear CMOS and plug the AC power cable in the power supply again to power on the system 11 Press Del continuously to enter the BIOS setup utility 12 Press F3 to load the default settings 13 After...

Страница 115: ...ts Drive Bay Supports two 2 5 drives Expansion Slots One 1 PCI Express 3 0 x4 Slot combined number of SATA ports and PCIe lane on slot is up to eight on 4C models One 1 M 2 PCI Express 3 0 x2 Slot Motherboard A2SDi 4C HLN4F Dimensions 6 7 L x 6 7 W 170 18 mm x 170 18 mm Chassis E302iL Dimensions WxHxD 11 6 x 3 x 8 1 in 295 x 76 x 206 mm System Cooling Fanless Power Supply 60W DC Power Adapter Weig...

Страница 116: ...0 4 6 BS EN 61000 4 8 BS EN 61000 4 11 Product Safety 2014 35 EU LVD Directive UL CSA 60950 1 2nd Edition UL CSA 62368 1 USA and Canada Electrical Equipment Safety Regulations 2016 IEC 60950 1 2nd Edition IEC BS EN 62368 1 Environment 2011 65 EU RoHS Directive EC 1907 2006 REACH 2012 19 EU WEEE Directive California Proposition 65 Perchlorate Warning California Best Management Practices Regulations...

Отзывы: