3-2
S
UPER
S
ERVER 6027R-CDNRT+ User's Manual
Universal Information LED States
State
Indication
Fast Blinking Red (1x/sec)
Fan Fail
Solid Red
CPU Overheat
Slow Blinking Red (1x/4 sec) Power Fail
Solid Blue
Local UID Button Depressed
Blinking Blue
IPMI-Activated UID
Universal Information LED
This LED will be blue when the UID function has been activated. When flashing
red it indicates a fan failure. When red continuously it indicates an overheat condi-
tion, which may be caused by cables obstructing the airflow in the system or the
ambient room temperature being too warm. Check the routing of the cables and
make sure all fans are present and operating normally. You should also check to
make sure that the chassis covers are installed. Finally, verify that the heatsinks
are installed properly (see Chapter 5). This LED will remain flashing or on as long
as the indicated condition exists.
1
3-3 Control Panel LEDs
The control panel located on the front of the chassis has several LEDs. These
LEDs provide you with critical information related to different parts of the system.
This section explains what each LED indicates when illuminated and any corrective
action you may need to take.
Power Fail
Indicates a power supply module has failed. The second power supply module will
take the load and keep the system running but the failed module will need to be
replaced. Refer to Chapter 6 for details on replacing the power supply. This LED
should be off when the system is operating normally.
NIC1
Indicates network activity on the LAN1 port when flashing.
Содержание SUPERSERVER 6027R-CDNRT+
Страница 1: ...SUPER SUPERSERVER 6027R CDNRT USER S MANUAL 1 0...
Страница 5: ...Notes Preface v...
Страница 10: ...Notes SUPERSERVER 6027R CDNRT User s Manual x...
Страница 16: ...1 6 SUPERSERVER 6027R CDNRT User s Manual Notes...
Страница 24: ...2 8 SUPERSERVER 6027R CDNRT User s Manual Notes...
Страница 48: ...4 20 SUPERSERVER 6027R CDNRT User s Manual Notes...
Страница 78: ...5 30 SUPERSERVER 6027R CDNRT User s Manual Notes...
Страница 87: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 7 Removing the Power Supply Handle Release Tab...
Страница 88: ...6 10 SUPERSERVER 6027R CDNRT User s Manual Notes...
Страница 122: ...7 34 SUPERSERVER 6027R CDNRT User s Manual Notes...
Страница 124: ...A 2 SUPERSERVER 6027R CDNRT User s Manual Notes...