background image

25

Chapter 3: Maintenance and Component Installation

Removing and Installing Motherboard Nodes

The chassis features twelve removable nodes. Each node contains a motherboard and hard 
drives mounted on a sled, allowing for convenient installation and removal.

Figure 3-2. Removing/Installing a Node

Release Tab

Handle

Removing Nodes from the System

1. Power down the individual node by pressing the node's power button.

2. Press and hold down the release tab on the front of the node.

3. Use the handle to pull the node from the system.

Caution:

 Except for short periods of time while swapping nodes, do not operate the server 

with the node bays empty. In the event of node failure, remove the failed node and replace 
it with the dummy node that was included with the system.

Содержание SuperServer 5039MA16-H12RFT

Страница 1: ...USER S MANUAL Revision 1 0 SuperServer 5039MA8 H12RFT 5039MA16 H12RFT...

Страница 2: ...pment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manua...

Страница 3: ...user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities https www supermicro com wftp driver Product safety info http www superm...

Страница 4: ...paring for Setup 17 Choosing a Setup Location 17 Rack Precautions 17 System Precautions 18 Rack Mounting Considerations 18 Ambient Operating Temperature 18 Airflow 18 Mechanical Loading 18 Circuit Ove...

Страница 5: ...Chapter 4 Motherboard Connections 4 1 Node Front Panel Controls 36 4 2 Headers and Connectors 36 4 3 Ports 38 I O Ports 38 4 4 Jumpers 40 4 5 LED Indicators 42 Chapter 5 Software 5 1 Microsoft Windows...

Страница 6: ...6 SuperServer 5039MA8 16 H12RFT User s Manual Appendix A BIOS Codes Appendix B Standardized Warning Statements for AC Systems Appendix C System Specifications Appendix D UEFI BIOS Recovery...

Страница 7: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermi...

Страница 8: ...Air Shroud MCP 310 93903 0N 12 Motherboard Tray MCP 220 93917 0N 12 HDD Backplane BPN SAS 939HS 1 Rail Kit MCP 290 41803 0N 1 1 2 Unpacking the System Inspect the box that the SuperServer 5039MA8 16...

Страница 9: ...m C3750F 3955F Socket Type FCBGA1310 Memory Up to 128GB of ECC VLP RDIMM and 64GB of ECC VLP UDIMM DDR4 memory with speeds of up to 2400MHz Chipset Intel C3000 SoC System on a Chip Hard Drives Interna...

Страница 10: ...ED The SC939HE R2K04BP is a twelve node chassis Each node has a main power button that also functions as a status LED See the table below for LED indications Node Power Button LED LED Appearance Node...

Страница 11: ...Chassis Features Item Feature Description 1 Node A removable motherboard node that supports two 3 5 drives or four 2 5 drives SATA3 or NVMe 2 Power Supply 2000W power supply module with LED Two module...

Страница 12: ...on 1 UID Button Unit identifier button and LED 2 Power Button Power button and LED 3 KVM Port Connect the adapter to this port to provide two USB2 ports and one serial port keyboard video mouse connec...

Страница 13: ...The illustration below shows the features included on the rear of the chassis Rear Chassis Features Item Feature Description 1 Power Port Use to connect the power supply to a grounded AC power outlet...

Страница 14: ...only JSD1 JPG1 JWD1 JVRM2 JVRM1 J2 JBT1 JTPM1 DIMMB2 DIMMB1 DIMMA2 DIMMA1 LED1 LED3 A C U15 JPME1 JBR1 JPTG1 BT1 1 J4 SW1 OSC1 1 JMD2 1 JMD1 LAN2 LAN1 I SATA2 SRW3 SRW2 SRW4 SRW1 A2SD1 3750F REV 1 01...

Страница 15: ...Status LED1 Onboard Power LED Solid Green Power On LED2 BMC Heartbeat LED Blinking Green BMC Normal LED3 UID LED Solid Blue Unit Identified Connector Description BT1 Onboard Battery I SATA2 I SATA3 SA...

Страница 16: ...ader RTL8211FS VGA AST2400 PCIe3 0_x1 8 0Gb s COM1 2 Header SATA III 6Gb s SATA III DOM USB2 0 2400 2133 1866 1600MHz U RDIMM U RDIMM RGMII 10Gbase T USB 2 0 480Mb s X557 AT2 AOM BPN MC12S R1 01 1000B...

Страница 17: ...hoosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated Leave at least...

Страница 18: ...and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep the front door of the rack and all co...

Страница 19: ...the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The following guidelines...

Страница 20: ...locations of the screws for the rails 3 In each rail set the two sections are screwed together to keep them immobile during shipping Release these screws just enough to allow the rail sections to slid...

Страница 21: ...ch handle Note These handles need only be installed when mounting the system into a short rack When mounting into a deep rack they are unnecessary and regular screws should be used instead of thumbscr...

Страница 22: ...SuperServer 5039MA8 16 H12RFT User s Manual 22 Figure 2 3 Installing the Server onto the Rails...

Страница 23: ...ed from the system or node This step is required when removing or installing non hot swap components or when replacing a non redundant power supply System Power 1 Use the operating system to power dow...

Страница 24: ...access to the inside of the chassis Removing the Top Cover 1 Remove power from the system as described in Section 3 1 2 Remove the screws securing the cover to the chassis 3 Lift the cover off the cha...

Страница 25: ...lling a Node Release Tab Handle Removing Nodes from the System 1 Power down the individual node by pressing the node s power button 2 Press and hold down the release tab on the front of the node 3 Use...

Страница 26: ...H12RFT User s Manual 26 Connecting to a Node USB and serial port capabilities can be added to any node through the KVM port on the front Plug in the adapter pictured below Figure 3 3 Adapter to Provid...

Страница 27: ...e when installing or removing DIMM modules to prevent any possible damage Memory Population Guidelines For optimal memory performance follow the table below when populating memory Populate DIMM slots...

Страница 28: ...in the following order DIMMA2 DIMMB2 then DIMMA1 DIMMB1 Use memory modules of the same type and speed for optimized performance 2 Push the release tabs outwards on both ends of the DIMM slot to unlock...

Страница 29: ...ower is removed This memory is powered by a lithium battery residing on the motherboard Replacing the Battery Begin by removing power from the system as described in Section 3 1 and remove the cover a...

Страница 30: ...ard drives in each node tray Installing Hard Drives 1 Power down the node and remove it from the chassis Refer to Section 3 2 2 Insert the hard drive with the printed circuit board side facing downwar...

Страница 31: ...ion Note Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers For information on recommended HDDs visit the Supermicro website at http www supermicro com product...

Страница 32: ...tire system This may be changed to two fan zones by opening jumper JP37 on the HDD backplane The figure below shows the two fan zone configuration Corresponding Nodes and Fans Cooling Zone Node Fans Z...

Страница 33: ...easily changed with no tools required and no need to remove any other parts inside the chassis Replacing a Fan 1 Push both release tabs on the failed fan 2 Remove the fan from the chassis The wiring...

Страница 34: ...fan efficiency Installing the Air Shroud 1 Remove the node from the chassis onto a flat non conductive surface 2 If necessary move any cables that interfere with the air shroud placement 3 Place the a...

Страница 35: ...100 120V or 180 240V An amber light will be illuminated on the power supply when the power is off An illuminated green light indicates that the power supply is operating Changing the Power Supply 1 Wi...

Страница 36: ...off the LED indicator The UID Indicator provides easy identification of a system unit that may be in need of service Note UID can also be triggered using IPMI on the motherboard For more information...

Страница 37: ...is located at JSD1 Connect appropriate cables here to provide power support for your Serial Link DOM devices DOM Power Pin Definitions Pin Definition 1 5V 2 Ground 3 Ground TPM Port 80 Header A Truste...

Страница 38: ...Serial Bus 2 0 ports USB0 1 are supported using the adapter in the KVM port M 2 Slot M 2 is formerly known as Next Generation Form Factor NGFF The A2SD1 3750F 3955F has two M 2 PCI E 3 0 slots that su...

Страница 39: ...on the back panel The UID LED LED3 is located next to the UID button When you press the UID button the UID LED will be turned on Press the UID button again to turn off the LED indicator The UID Indica...

Страница 40: ...oved Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally cl...

Страница 41: ...vailable via Recovery mode Refer to the table below for jumper settings ME Recovery Mode Jumper Settings Jumper Setting Definition Pins 1 2 Normal Pins 2 3 ME Recovery Watch Dog JWD1 controls the Watc...

Страница 42: ...w for jumper settings BIOS Recovery Jumper Settings Jumper Setting Definition Pins 1 2 Normal Pins 2 3 BIOS Recovery 10G Ethernet Enable Use JPTG1 to enable or disable 10G Ethernet support for the LAN...

Страница 43: ...e system and unplug the power cord before removing or installing components Onboard Power LED Indicator LED Color Definition Off System Off power cable not connected Green System On BMC Heartbeat LED...

Страница 44: ...site at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB...

Страница 45: ...iver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the S...

Страница 46: ...if preferred Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the f...

Страница 47: ...Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server you can r...

Страница 48: ...Intelligent Platform Management Interface IPMI IPMI is used to provide remote access monitoring and management There are several BIOS settings that are related to IPMI For general documentation and in...

Страница 49: ...F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be co...

Страница 50: ...and time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYY...

Страница 51: ...4 BIOS 51 Memory Information Total Memory This item displays the total size of memory available in the system Memory Speed This item displays the default speed of the memory modules installed in the...

Страница 52: ...feature to select the screen display between POST messages or the OEM logo at bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST mess...

Страница 53: ...tem from a Legacy boot device after its initial boot failure The options are Disabled and Legacy Boot Power Configuration Watch Dog Function If enabled the Watch Dog timer will allow the system to reb...

Страница 54: ...M1 Select Enable to activate TM1 support for system thermal monitoring TM1 allows the CPU to regulate its power consumption based upon the modulation of the CPU Internal clock when the CPU temperature...

Страница 55: ...mprove CPU performance The options are Enable and Disable ACPI 3 0 T States Available when CPU C States is set to Enabled Select Enable to support ACPI Advanced Configuration and Power Interface 3 0 T...

Страница 56: ...ity The options are Disable and Enable Lock PACKAGE_RAPL_LIMIT Use this feature to unlock the MSR 0x610 The options are Disable and Enable PL1 Time Window Use this feature to define the Running Averag...

Страница 57: ...The options are Disabled and Enabled NonVolatile Memory Setup Method Use this feature to select how data will be saved after power loss The options are Dis abled and NVDIMM If the feature above is set...

Страница 58: ...hen this feature is set to Enabled it sends a notification when ME initiates a global reset The options are Disabled and Enabled PMC WDT When this feature is Enabled it sends a notification when the P...

Страница 59: ...able or disable fast path through the memory reference code The options are Disabled and Enabled Command Address Parity Use this feature to enable or disable the DDR4 command address parity The option...

Страница 60: ...ctable error the error is corrected and sent to the requestor the original source Memory is corrected as well Select Enable to use Demand Scrubbing for ECC memory correction The options are Enabled an...

Страница 61: ...for EFI applications only The options are Enabled Disabled and Auto XHCI Hand Off This is a work around solution for operating systems that do not support XHCI Extensible Host Controller Interface han...

Страница 62: ...link in a low power mode during extended periods of I O inactivity and will return the link to an active state when I O activity resumes The options are Enabled and Disabled SATA 0 SGPIO LED Use this...

Страница 63: ...ATA 1 SGPIO LED Use this feature to select the SATA LED or SGPIO LED The options are SGPIO and SATA LED I SATA2 I SATA8 This following information is displayed for each SATA drive entry Device Informa...

Страница 64: ...ualization support SR IOV is an extension of the PCI Express interface and consists of two functions physical functions PF and virtual functions VF PF is the primary function and is used to control an...

Страница 65: ...on card for this slot The options are Disabled Legacy and EFI Onboard LAN OPROM Type Use this feature to select the Onboard LAN Option ROM type The options are Disabled Legacy and EFI Onboard Video O...

Страница 66: ...is item is hidden when Serial Port 1 is set to Disabled Serial Port 1 Change Settings This feature specifies the base I O port address and the Interrupt Request address of Serial Port 1 Select Auto fo...

Страница 67: ...bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits...

Страница 68: ...e this feature to specify how the host computer will exchange data with the client computer which is the remote computer used by the user SOL Terminal Type Use this feature to select the target termin...

Страница 69: ...to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start sending data when the receiving buffer is empty T...

Страница 70: ...lect Enabled to use a COM port selected by the user for EMS Console Redirection The options are Disabled and Enabled If the feature above is set to Enabled the following features are available for con...

Страница 71: ...Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits is odd Select None if you do not want to send...

Страница 72: ...6 PCR Bank and additional settings will become available for configuration SHA 1 PCR Bank Use this feature to disable or enable the SHA 1 Platform Configuration Register PCR bank for the installed TPM...

Страница 73: ...PM 2 0 devices Select Auto to enable support for both versions The options are TPM 1 2 TPM 2 0 and Auto iSCSI Configuration iSCSI Initiator Name This feature allows the user to enter the unique name o...

Страница 74: ...ecify the duration for LEDs to blink The range is from 0 15 seconds The default setting is 0 Port Configuration Information This section displays the following port information UEFI Driver Adapter PBA...

Страница 75: ...ature to enable or disable PCIe error logging suport The options are Disabled and Enabled Memory ELog Support Use this feature to enable or disable memory error logging suport The options are Disabled...

Страница 76: ...y SMBIOS Event Log Standard Settings Log System Boot Event Select Enabled to log system boot events The options are Enabled and Disabled MECI Multiple Event Count Increment Enter the increment value f...

Страница 77: ...your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Disabled and Enabled Erasing Settings Erase SEL Select Yes...

Страница 78: ...nd Yes If the item above is set to Yes Configuration Address Source and VLAN available for configuration Configuration Address Source Use this feature to select the source of the IP address for this c...

Страница 79: ...the IPMI VLAN function The options are Disable and Enable IPMI Function Support Use this feature to enable IPMI support The options are Disabled and Enabled When disabled the system powers on quicker...

Страница 80: ...The options are Setup and Always Administrator Password Use this feature to set the administrator password which is required to enter the BIOS setup utility The length of the password should be from...

Страница 81: ...led Restore Factory Keys Select Yes to install the default settings for all keys The options are Yes and No Enroll Efi Image This feature allows the image to run in Secure Boot mode Save All Secure Bo...

Страница 82: ...DBX from the manufacturer s defaults to the existing DBX Select No to load the DBX from a file The options are Yes and No Authorized TimeStamps Set New Select Yes to load the DBT from the manufacturer...

Страница 83: ...GACY UEFI and DUAL Fixed Boot Order Priorities This option prioritizes the order of bootable devices that the system to boot from Press Enter on each entry from top to bottom to select devices UEFI Bo...

Страница 84: ...d devices The options are the list of detected boot device s and Disabled UEFI NETWORK Drive BBS Priorities Boot Option This feature sets the system boot order of detected devices The options are the...

Страница 85: ...ges and Exit Select this feature to quit the BIOS Setup without making any permanent changes to the system configuration and reboot the computer Select Discard Changes and Exit from the Exit menu and...

Страница 86: ...the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Exit menu and p...

Страница 87: ...he boot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The tab...

Страница 88: ...ermicro com support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a d...

Страница 89: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 90: ...o considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar...

Страница 91: ...erken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aa...

Страница 92: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 93: ...entes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l in...

Страница 94: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 95: ...mkabels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment...

Страница 96: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 97: ...so a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc...

Страница 98: ...mblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorr...

Страница 99: ...nt aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All...

Страница 100: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 101: ...g Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectrique...

Страница 102: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 103: ...ionale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled acc...

Страница 104: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 105: ...s destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soien...

Страница 106: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...

Страница 107: ...sur le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto...

Страница 108: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Страница 109: ...2SD1 3750 F 3955F proprietary form factor Dimensions 4 6 x 11 70 11 68 x 29 72 cm Chassis SC939HE R2K04BP 3U rackmount Dimensions WxHxD 17 5 x 5 21 x 29 5 in 444 5 x 132 x 749 3 mm Weight Net 132 lbs...

Страница 110: ...0 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Other VCCI CISPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU and Directive 2012 19 EU Perc...

Страница 111: ...he recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the system pow...

Страница 112: ...ing a different machine copy the Super ROM binary image file into the Root directory of a USB device or a writable CD DVD Note 1 If you cannot locate the Super ROM file in your drive disk visit our we...

Страница 113: ...you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 4 When the screen as shown above displays use the arrow keys to select the item Proceed with...

Страница 114: ...m boot to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Bu...

Страница 115: ...rupt this process until the BIOS flashing is complete 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power suppl...

Отзывы: