background image

USER’S MANUAL

Revision 1.0a

S

UPER

S

ERVER

®

5038MR-H8TRF

Содержание SuperServer 5038MR-H8TRF

Страница 1: ...USER S MANUAL Revision 1 0a SUPERSERVER 5038MR H8TRF...

Страница 2: ...f any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limit...

Страница 3: ...and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities ftp ftp supermicro com Product safety info http www supermicro co...

Страница 4: ...1 Choosing a Setup Location 2 1 2 3 Warnings and Precautions 2 2 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2 3 Ambient Operating Temperature 2 3 Reduced Airflow 2 3 Mech...

Страница 5: ...ndant Power Supplies if applicable to your system 4 12 Backplane Voltage if applicable to your system 4 13 Comply with Local and National Electrical Codes 4 14 Product Disposal 4 15 Hot Swap Fan Warni...

Страница 6: ...Removing Motherboard Nodes 6 5 6 6 Installing Hard Drives 6 6 6 7 Installing an Air Shroud 6 9 6 8 System Fans 6 10 6 9 Power Supply 6 11 Replacing a Power Supply Module 6 11 6 10 Removing and Install...

Страница 7: ...uper Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technica...

Страница 8: ...8 SUPERSERVER 5038MR H8TRF User s Manual Notes...

Страница 9: ...cm system cooling fans FAN 0133L4 One rackmount rail kit MCP 290 00057 0N Per node Expansion card AOC CGP I2 O P Heatsink SNK P0047PS One air shroud MCP 310 93802 0B Riser Card RSC RR1U E8 O P Note F...

Страница 10: ...GA2011 sockets Socket R3 Refer to the Supermicro web site for a complete listing of supported processors www supermicro com Memory The serverboard has four memory sockets that can support up to 256 GB...

Страница 11: ...apter 5 for details LPC JPCIE1 PCIE 3 0 x16 DDR3 DIMM B1 DDR3 DIMM A1 DMI USB PROCESSOR QPI1 QPI0 PCI E x1 PCH DMI HEADER Vertical USB CONN 6 USB 3 0 1 2 DDR3 DIMM C1 D1 DDR3 DIMM Socket 00 CPU0 BMC A...

Страница 12: ...or is replaced Hard Drives The chassis supports up to sixteen 3 5 hot swap hard drives connected through a SAS backplane PCI Expansion Slots Each node allows one PCI E x8 low profile expansion card u...

Страница 13: ...e Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro...

Страница 14: ...1 6 SUPERSERVER 5038MR H8TRF User s Manual Notes...

Страница 15: ...ed Avoid areas where heat electrical noise and electromagnetic fields are generated A nearby grounded power outlet is required The box your chassis was shipped in should include two sets of rail assem...

Страница 16: ...two or more simultaneously may cause the rack to become unstable Server Precautions Review the electrical and general safety precautions in Chapter 4 Determine the placement of each component in the r...

Страница 17: ...ve on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable Ground A reliable ground must be main...

Страница 18: ...26 5 and 36 4 deep Identifying the Sections of the Rack Rails The chassis package includes two rail assemblies Each assembly consists of three sections An inner rail that secures directly to the chas...

Страница 19: ...ack when when the chassis is pulled out for servicing To mount the rail onto the chassis first release the inner rail from the outer rails Releasing Inner Rail from the Outer Rails 1 Pull the inner ra...

Страница 20: ...he inner rail firmly against the side of the chassis aligning the hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassis until...

Страница 21: ...r rails to the rack 4 Pull out the rear of the outer rail adjusting the length until it just fits within the posts of the rack 5 Hang the hooks of the rear section of the outer rail onto the square ho...

Страница 22: ...illustrated above 2 Align the inner rails of the chassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has bee...

Страница 23: ...on the front that houses the chassis power buttons and status monitoring lights Each node has a power button and status lights on the rear There are status lights on each of the hard drives and statu...

Страница 24: ...the server system Turning off system power with this button removes the main power but keeps standby power supplied to the system Therefore you must unplug system before servicing Reset The reset butt...

Страница 25: ...d operating normally Blinking Green The node is in the process of shutting down Solid Red The node is detecting an overheated condition 1Hz Blinking Red The node is detecting a fan failure 25Hz Blinki...

Страница 26: ...ing Pattern Behavior for Device Activity LED Blue Solid On SAS drive installed Blue Blinking I O activity Status LED Red Solid On Failed drive for SAS SATA with RSTe support Red Blinking at 1 Hz Rebui...

Страница 27: ...ailure LED Red Power Button and LED Green Figure 3 3 Rear Node LED Indicators Power Button and LED This button will power on the node individually It is illuminated green when the node is powered on i...

Страница 28: ...fully inserted into its bay 3 6 Power Supply LEDs On the rear of the power supply module an LED displays the status Solid Green When illuminated indicates that the power supply is on Solid Amber When...

Страница 29: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis Th...

Страница 30: ...considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar...

Страница 31: ...l kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard proc...

Страница 32: ...ie en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de branch...

Страница 33: ...talliert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuitos o sobrecorrient...

Страница 34: ...um Systemsbestandteile anzubringen oder zu entfernen Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the c...

Страница 35: ...nentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enle...

Страница 36: ...arnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o...

Страница 37: ...stallation in Bereichen mit beschr nktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m gli...

Страница 38: ...ame or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een...

Страница 39: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 40: ...para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour suppri...

Страница 41: ...ero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circulent sur le fond de panier Prendre des pr cautions lors de la maintenanc...

Страница 42: ...lectrical codes Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Bac...

Страница 43: ...re install conform ment aux normes lectriques nationales et locales Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften Warnung Di...

Страница 44: ...rdous moving parts Keep away from moving fan blades The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from the openings...

Страница 45: ...s destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soien...

Страница 46: ...the code for any other electrical devices than products designated by Supermicro only Power Cable and AC Adapter Warnung Nutzen Sie beim Installieren des Produkts ausschlie lich die von uns zur Verf g...

Страница 47: ...ros dispositivos el ctricos que los productos designados nicamente por Supermicro Attention Attention Lors de l installation du produit utilisez les cables de connection fournis ou d sign ou achetez d...

Страница 48: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storing...

Страница 49: ...hat the size and weight of the serverboard can cause it to bend if handled improperly which may result in damage To prevent the serverboard from bending keep one hand under the center of the board to...

Страница 50: ...e only an Intel certified multi directional heatsink Avoid placing direct pressure to the top of the processor package Install the processor into the CPU socket before installing the heatsink Refer to...

Страница 51: ...edges will fit the socket OPEN1st IMPORTANT Caution You can only install the CPU into the socket in one direction Make sure that the CPU is properly inserted into the socket before closing the load pl...

Страница 52: ...and lock the Close 1st lever Push down and lock the lever labeled Open 1st OPEN1st OPEN1st Push down and lock the lever labeled Close 1st 9 Close and lock the Open 1st lever Engage the lip of the loa...

Страница 53: ...to loosen it from the CPU Do not use excessive force 4 Once the heatsink is loosened remove it from the CPU 5 Clean the surface of the CPU and the heatsink to get rid of the old thermal grease Reappl...

Страница 54: ...5038MR H8TRF User s Manual 5 3 Input Output Ports The I O ports at the rear of the server are pictured below Figure 5 2 Rear Panel I O Ports 1 4 3 2 1 KVM Port 2 IPMI dedicated LAN 3 Power Button and...

Страница 55: ...IMMA1 DIMMB1 DIMMC1 and DIMMD1 Always use DDR4 DIMM modules of the same size type and speed Mixed DIMM speeds can be installed However all DIMMs will run at the speed of the slowest DIMM The motherboa...

Страница 56: ...3 0 X8 USB1 3 0 JUSB2 DIMMC1 DIMMD1 DIMMA1 DIMMB1 Figure 5 3 DIMM Slot Labels Figure 5 4 Installing DIMM into Slot Socket Key Release Tab Release Tab Insert the desired number of DIMMs into the memory...

Страница 57: ...JBR1 JWD1 JVRM1 JVRM2 JBT1 JIPMB1 LEDM1 LED2 LED1 JUIDB1 S SGPIO1 S SGPIO2 JSD1 KVM IPMI_LAN FAN1 USB0 1 P1 DIMMD1 P1 DIMMC1 P1 DIMMB1 UID P1 DIMMA1 CPU1 SLOT1 PCI E 3 0 X8 CPU1 MICRO LP PCI E 3 0 X8...

Страница 58: ...tem Fan Header IPMI_LAN IPMI Dedicated LAN Port I SATA4 I SATA5 SATA 3 0 Ports supported by Intel PCH JIPMB1 System Management Bus Header for the IPMI Slot JPCIE1 MicroLP PCI E 3 0 X8 Slot JPCIE2 Slot...

Страница 59: ...t IPMI Port A dedicated IPMI LAN port is located next to the KVM port to provide dedicated network connection for IPMI 2 0 Power Button LED A power button SW1 and LED is located next to the IPMI port...

Страница 60: ...the table on the right for pin definitions Trusted Platform Module Header Pin Definitions Pin Definition Pin Definition 1 LCLK 2 GND 3 LFRAME 4 No Pin 5 LRESET 6 VCC5 7 LAD3 8 LAD2 9 VCC3 10 LAD1 11...

Страница 61: ...ns only The fan speeds are controlled by Thermal Management via the IPMI 2 0 interface Internal Buzzer The internal buzzer located at SP1 can be used to provide audible alarms for various beep codes I...

Страница 62: ...ound 7 Clock 8 N NC No Connection Unit Identifier Buttons UID LED Indicators A rear unit identifier button JUIDB2 is located next to the COM port The connection for the front UID button is located on...

Страница 63: ...e pins CMOS Clear JBT1 is used to clear CMOS and will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS...

Страница 64: ...signal for the application that hangs Watch Dog must also be enabled in the BIOS Watch Dog Jumper Settings Pin Definition 1 2 Reset default 2 3 NMI Open Disabled Manufacturing Mode Close pins 2 and 3...

Страница 65: ...for VRM Jumpers JVRM1 and JVRM2 allow the BMC or the PCH to access CPU and memory VRM controllers VRM Pin Defintions Pin Definition 1 2 BMC Default 2 3 PCH Power Force On Enable Disable Jumpers JPF1 a...

Страница 66: ...bles the user to pinpoint this particular motherboard that may be in need of service Turn on the UID button in the front of the chassis or on the motherboard s I O panel to identify the unit in need o...

Страница 67: ...rts Two SATA 3 0 connectors I SATA4 I SATA5 and two SAS 3 0 connectors SAS0 SAS1 are located on the motherboard to provide Serial Link connections I SATA ports are supported by the Intel PCH C612 chip...

Страница 68: ...Website at http www supermicro com products Find the product page for your serverboard here where you may download individual drivers and utilities After creating a CD DVD with the ISO files insert t...

Страница 69: ...a email or Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 M...

Страница 70: ...ndfill Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly Figure 5 9 Installing the Onboard Battery OR Note The SuperDoc...

Страница 71: ...Chapter 5 Advanced Serverboard Setup 5 23 Notes...

Страница 72: ...y tool required is a Phillips screwdriver Review the warnings and precautions listed in the manual before setting up or servicing this chassis These include information in Chapter 2 Warning Statements...

Страница 73: ...rocedure to ensure that power has been removed from the system 1 Use the operating system to power down the system following the on screen prompts 2 After the system has completely shut down carefully...

Страница 74: ...he three screws which secure the top cover to the chassis as illustrated above 3 Lift the top cover up and off the chassis 4 Peel off the protective film covering the top cover and the top of the chas...

Страница 75: ...ote that if a node is pulled out of the chassis the hard drives associated with that node will power down Corresponding Nodes Fans and HDDs Node Fan HDDs Node 1 Fan 1 HDDs A1 and A2 Node 2 Fan 1 HDDs...

Страница 76: ...g Nodes from the System Release Tab Node Power LED Node Power Button Node Handle Removing Nodes from the System 1 Power down the individual node by pressing that node s power button 2 Press and hold d...

Страница 77: ...xteen hot swappable hard drives These hard drives are contained in drive carriers and may be removed without powering down the system Removing Hard Drive Carriers from the Chassis 1 Press the release...

Страница 78: ...e Drive Carrier 1 Remove the hard drive carrier from the chassis as described in the previous section and lay the drive carrier on a flat surface 2 Remove the two screws securing the dummy drive to th...

Страница 79: ...e hard drive to the carrier with the four screws included with the hard drive 4 Use the open handle of the drive carrier to insert the drive carrier into the open drive bay 5 Secure the drive carrier...

Страница 80: ...e Make sure that the expansion card if present and all components are installed in each node before installing the air shroud Installing the Air Shroud Place the air shroud over the motherboard The ai...

Страница 81: ...ystem is operating and observe Do not run the server for an extended period of time with the top cover open 2 Remove the failed fan s power cord from the backplane 3 Simultaneously squeeze both releas...

Страница 82: ...icates that the power supply is operating Replacing a Power Supply Module If either of the two power supply modules fail the other module will take the full load and allow the system to continue opera...

Страница 83: ...pply The system can continue running 2 Press the release tab at the top of the power supply 3 Push and hold the release tab on the back of the power supply 4 Pull the power supply out using the handle...

Страница 84: ...of a backplane failure follow the instructions below to replace it Removing the Backplane and Fan Bracket Assembly Removing the Backplane and Fan Bracket from the Chassis 1 Power down the system and d...

Страница 85: ...brackets to the sides of the fan bracket and set them aside for later use Remove the side mounting brackets 2 Remove the eleven screws securing the backplane to the fan bracket and set these screws as...

Страница 86: ...sis 2 Hold the backplane by its edges and carefully place it against the fan mounting bracket aligning the mounting holes in the backplane with those in the fan bracket 3 Secure the two side mounting...

Страница 87: ...Assembly Installing the Backplane and Fan Bracket 1 Ensure that the chassis has been disconnected from any power source 2 Reconnect the wiring to the backplane 3 Insert the fan bracket and backplane a...

Страница 88: ...a reserved for informational text When an option is selected in the left frame it is highlighted in white Often informational text will accompany it Note The AMI BIOS has default informational message...

Страница 89: ...he wrong BIOS can cause irreparable damage to the system In no event shall the manufacturer be liable for direct indirect special incidental or consequential damage arising from a BIOS update If you h...

Страница 90: ...F BIOS Version This item displays the version of the BIOS ROM used in this system Build Date This item displays the date that the BIOS setup utility was built Memory Information Total Memory This dis...

Страница 91: ...his occurs revert to the default setting BOOT Feature Quiet Boot This option allows the bootup screen options to be modified between POST mes sages or the OEM logo Select Disabled to display the POST...

Страница 92: ...the Watch Dog timer will allow the system to automatically reboot when a non recoverable error occurs that lasts for more than five minutes The options are Enabled and Disabled Power Button Function...

Страница 93: ...abled and Enabled Hyper Threading ALL Set to Enabled to use the processor s Hyper Threading Technology feature The options are Enabled and Disabled Cores Enabled Set a numeric value to enable the numb...

Страница 94: ...Enabled to activate the L1 Data Prefetcher based on sequential load history The options are Enable and Disable Direct Cache Access DCA Select Enabled to use Intel s DCA Direct Cache Access Technology...

Страница 95: ...ormance Balanced Performance Balanced Power and Power Energy Efficient Turbo Use this feature to enable energy efficient turbo mode The options are Enable and Disable CPU P State Control EIST P States...

Страница 96: ...operating system During the CPU C6 state power to all caches is turned off The options are Enable and Disable Enhanced Halt State C1E Select Enabled to enable Enhanced Halt State support which will si...

Страница 97: ...tion 3 8 GT s IOAT Configuration Enable I OAT Select Enable to enable Intel I OAT I O Acceleration Technology which signifi cantly reduces CPU overhead by leveraging CPU architectural improvements and...

Страница 98: ...Enable Available when the OS and the CPU support this feature Select Enabled for Cluster On Die support to enhance system performance in cloud computing The options are Enabled and Disable Early Snoo...

Страница 99: ...mance The options are Enabled and Disabled DRAM RAPL Running Average Power Limit Baseline Use this feature to set the run time power limit baseline for DRAM modules The options are Disable DRAM RAPL M...

Страница 100: ...ne cache line every 16K cycles if there is no delay caused by internal processing By using this method roughly 64 GB of memory behind the IO hub will be scrubbed every day The options are Enable and D...

Страница 101: ...by the XHCI driver The settings are Enabled and Disabled EHCI Hand Off This item is for operating systems that do not support Enhanced Host Controller Interface EHCI hand off When this item is enabled...

Страница 102: ...are Enabled and Disabled Configure SATA as Select IDE to configure a SATA drive specified by the user as an IDE drive Select AHCI to configure a SATA drive specified by the user as an AHCI drive Sele...

Страница 103: ...set to IDE the following items will display Serial ATA Port 0 Port 5 This item indicates that a SATA port specified by the user is not installed or not present Port 0 Port 5 SATA Device Type Availabl...

Страница 104: ...ithout shutting down the system The options are Enabled and Disabled Port 0 Port 5 Spin Up Device On an edge detect from 0 to 1 set this item to allow the PCH to start a COMRESET initialization to the...

Страница 105: ...gle Root IO Virtualization support The options are Enabled and Disabled Maximum Payload Select Auto for the system BIOS to automatically set the maximum payload value for a PCI E device to enhance sys...

Страница 106: ...I Onboard Video Option ROM Use this item to select the Onboard Video Option ROM type The options are Legacy and EFI VGA Priority Use this item to select the graphics device to be used as the primary v...

Страница 107: ...1 Console Redirection Select Enabled to enable COM Port 1 for Console Redirection which will allow a client machine to be connected to a host machine at a remote site for networking The options are E...

Страница 108: ...l data communication Select 2 Stop Bits if slower devices are used The options are 1 and 2 Flow Control Use this item to set the flow control for Console Redirection to prevent data loss caused by buf...

Страница 109: ...L COM2 Console Redirection Settings Use this feature to specify how the host computer will exchange data with the client computer which is the remote computer used by the user Terminal Type Use this f...

Страница 110: ...Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start sending data when the receiving buffer...

Страница 111: ...ngs This feature allows the user to specify how the host computer will exchange data with the client computer which is the remote computer used by the user Out of Band Management Port The feature sele...

Страница 112: ...HEA plat form and provide a common infrastructure for the system to handle hardware errors within the Windows OS environment to reduce system crashes and to enhance system recovery and health monitori...

Страница 113: ...d Runtime Error Logging Support Change this item to enable or disable runtime error logging The options are En abled and Disabled Memory Correction Error Threshold Change this item to define the syste...

Страница 114: ...Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This item is used...

Страница 115: ...stem Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings Erase SEL Select Yes On next reset...

Страница 116: ...Update IPMI LAN Configuration This feature allows the user to decide if the BIOS should configure the IPMI setting at next system boot The options are No and Yes If the option is set to Yes the user...

Страница 117: ...the Gateway or Router address i e 192 168 10 1 7 6 Security This menu allows the user to configure the following security settings for the system Password Check Select Setup for the system to check fo...

Страница 118: ...nagement This submenu allows the user to configure the following Key Management settings Default Key Provision Select Enabled to install the default Secure Boot keys set by the manufacturer The option...

Страница 119: ...from a file The options are Yes and No Append DB Select Yes to add the DB from the manufacturer s defaults list to the existing DBT Select No to load the DBT from a file The options are Yes and No Au...

Страница 120: ...BIOS to wait before rebooting the system when the setup activation key is pressed Enter the value of 65535 0xFFFF for the BIOS to wait indefinitely The default setting is 1 Boot Mode Select Use this...

Страница 121: ...priority list Delete Boot Option Select the target boot device to delete Network Drive BBS Priorities Legacy Boot Order 1 This feature sets the system boot order of detected devices The options are t...

Страница 122: ...hanges and Reset When you have completed the system configuration changes select this option to leave the BIOS Setup Utility and reboot the computer so the new system con figuration parameters can tak...

Страница 123: ...faults from the Exit menu and press En ter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Ex...

Страница 124: ...fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the corresponding error X10 Serverboard BIOS Error Bee...

Страница 125: ...A 2 SUPERSERVER 5038MR H8TRF User s Manual Notes...

Страница 126: ...off control to a computer system at bootup B 2 How to Recover the UEFI BIOS Image the Main BIOS Block A UEFI BIOS flash chip consists of a recovery BIOS block and a main BIOS block a main BIOS image...

Страница 127: ...ur website at www supermicro com to download the BIOS image into a USB flash device and rename it Super ROM for BIOS recovery use 2 Insert the USB device that contains the new BIOS image Super ROM int...

Страница 128: ...u want to start with BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 5 When the screen as shown above displays using the arrow key select the item Proceed with fl...

Страница 129: ...prompt Note Do not interrupt this process until BIOS flashing is completed 9 After seeing the message that BIOS update is completed unplug the AC power cable from the power supply to clear the CMOS a...

Страница 130: ...t BIOS 128 Mb SPI AMI BIOS SM Flash BIOS Memory Capacity Per node four sockets supporting up to 256 GB RDIMM and LRDIMM ECC DDR4 2133 1866 1600 Hz SATA Controller Two SATA3 ports on the back panel two...

Страница 131: ...ted Output Voltages 1000W 12V 84A 5Vsb 4A 1200W 12V 100A 5Vsb 4A 1620W 12V 150A 5Vsb 4A Operating Environment Operating Temperature 10 C to 35 C 50 F to 95 F Expanded Operating Temperature 5 C to 40 C...

Страница 132: ...1000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe California Best Management Practices Regulations...

Страница 133: ...erform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such...

Отзывы: