A-2
SUPERSERVER 5028D-TN4T User's Manual
Chassis
SC721TQ-250B mini-tower
Dimensions: height 9.45" (240.03mm), width 8.27" (210.06mm),
depth 11" (279.4mm)
System Cooling
One 12-cm fan
System Input Requirements
AC Input: 100-240 VAC, 50-60 Hz
Rated Input Current: 5 Amp
Power Supply
Part# PWS-251-1H, Flex ATX Multi-output, 80 Plus Bronze level
Rated Output Power: 250 W
Rated Output Voltages:
+12V
Max:18 Amp; Min:1 Amp @100V-240V
-12V
Max: 3 Amp; Min: 0 Amp
+5V
Max:14 Amp; Min:0.5 Amp
+3.3V
Max: 12 Amp Min: 0.3Amp
5VSB
Max: 2.5 Amp Min: 0 Amp
Operating Environment
Operating Temperature: 5°C ~ 40°C (41°F ~ 104°F)
Non-Operating Temperature: -40°C ~ 60°C (-40°F ~ 140°F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-Operating Relative Humidity: 5% to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class B, EN 55022 Class B, EN 61000-3-2/-3-
3, CISPR 22 Class B
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and
Canada), CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply.
See www.dtsc.ca.gov/hazardouswaste/perchlorate”
Содержание SUPERSERVER 5028D-TN4T
Страница 1: ...USER S MANUAL Revision 1 0a SUPERSERVER 5028D TN4T...
Страница 8: ...8 SUPERSERVER 5028D TN4T Manual Notes...
Страница 14: ...1 6 SUPERSERVER 5028D TN4T User s Manual Notes...
Страница 18: ...SUPERSERVER 5028D TN4T User s Manual 2 4 Notes...
Страница 38: ...3 20 SUPERSERVER 5028D TN4T User s Manual Notes...
Страница 118: ...A 4 SUPERSERVER 5028D TN4T User s Manual Notes...