Chapter 7: BIOS
7-9
Slot1 PCI-Exp. x8, Slot2 PCI-Exp. x8 and Slot3 PCI-Exp. x4
Access the submenu for each of the settings above to make changes to the
following:
Option ROM Scan
When enabled, this setting will initialize the device expansion ROM. The options
are
Enabled
and Disabled.
Enable Master
This setting allows you to enable the selected device as the PCI bus master.
The options are
Enabled
and Disabled.
Latency Timer
This setting allows you to set the clock rate for Bus Master. A high-priority, high-
throughout device may benefi t from a greater clock rate. The options are
Default
,
0020h, 0040h, 0060h, 0080h, 00A0h, 00C0h, and 00E0h. For Unix, Novell and
other Operating Systems, please select the option: other. If a drive fails after
the installation of a new software, you might want to change this setting and
try again. A different OS requires a different Bus Master clock rate
.
Large Disk Access Mode
This setting determines how large hard drives are to be accessed. The options are
DOS
or Other (for Unix, Novelle NetWare and other operating systems).
Advanced Chipset Control
Access the submenu to make changes to the following settings.
Warning
: Use caution when changing the Advanced settings. Incorrect
values entered may cause system malfunction. Also, a very high DRAM
frequency or incorrect DRAM timing may cause system instability. When
this occurs, revert to the default setting.
Clock Spectrum Feature
If Enabled, the BIOS will monitor the level of Electromagnetic Interference caused
by the components and will attempt to decrease the interference whenever needed.
The options are Enabled and
Disabled
.
ECC Conditions
(
Available when supported by the memory
)
This setting specifi es ECC Error conditions that will be treated as ECC Error Events.
The options are None, Single Bit,
Multiple Bit,
and Both.
ECC Error Handler
(
Available when supported by the memory
)
This setting allows you to select the type of interrupt to be activated when an ECC
error occurs. The options are None, NMI (Non-Maskable Interrupt),
SMI
(System
Management Interrupt) and SCI (System Control Interrupt.)
!
Содержание SUPERSERVER 5025M-UR
Страница 1: ...SUPERSERVER 5025M UR USER S MANUAL 1 0 SUPER ...
Страница 5: ...v Preface Notes ...
Страница 10: ...Notes x SUPERSERVER 5025M UR User s Manual ...
Страница 21: ...Chapter 2 Server Installation 2 5 Figure 2 1 Installing Chassis Rails ...
Страница 23: ...Chapter 2 Server Installation 2 7 Figure 2 2 Installing the Server into a Rack ...
Страница 25: ...Chapter 2 Server Installation 2 9 Figure 2 3 Accessing the Inside of the System ...
Страница 30: ...SUPERSERVER 5025M UR User s Manual 3 4 Notes ...
Страница 58: ...5 24 SUPERSERVER 5025M UR User s Manual Notes ...
Страница 90: ...A 6 SUPERSERVER 5025M UR User s Manual Notes ...
Страница 96: ...B 6 SUPERSERVER 5025M UR User s Manual Notes ...
Страница 130: ...E 4 SUPERSERVER 5025M UR User s Manual Notes ...