SuperServer 5019S-WR User's Manual

Appendix B: Standardized Warning Statements

Warnung
Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen 
wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des 
Lüftergehäuses entfernt.

¡Advertencia! 

Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis. 
Mandtenga  los  dedos,  los  destornilladores  y  todos  los  objetos  lejos  de  las  aberturas  del 

ventilador

Attention 

Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc 
ventilateur du châssis. Prenez garde à ce que doigts, tournevis et autres objets soient éloignés 

du logement du bloc ventilateur.

!הרהזא

 

יקלח תא םיריסמ רשאכ

 

 שי .םידבוע ןיידע םיררוואמהו ןכתי ,זראמהמ ררוואמה

 קיחרהל

ל

ררוואמה ךותב םיחתפהמ םינוש הדובע ילכו תועבצאה תא חוטב קחרמ

 

 

هكممنا هم

 

حوارمنا نأ

 

لاست لا

 

ةنازإ دنعرودت

 

ةهتك

 

ةحورمنا

 

مكيهنا هم

 

بجي

 

ءاقبإ

 

عباصلأا

 

و

يغاربنا تاكفم

 

.

ءايشلأا هم اهريغو

 

اديعب

 

هع

 

تاحتفنا

 

يف

 

ةهتك

 

ةحورمنا

  

 

 

경고!

섀시로부터 팬 조립품을 제거할 때 팬은 여전히 회전하고 있을 수 있습니다. 팬 조림품 
외관의 열려있는 부분들로부터 손가락 및 스크류드라이버, 다른 물체들이 가까이 하지 
않도록 배치해 주십시오. 

Waarschuwing

Het is mogelijk dat de ventilator nog draait tijdens het verwijderen van het ventilatorsamenstel 

uit het chassis. Houd uw vingers, schroevendraaiers en eventuele andere voorwerpen uit de 
buurt van de openingen in de ventilatorbehuizing.

Power Cable and AC Adapter 

Warnung 
Bei der Installation des Produkts, die zur Verfügung gestellten oder benannt Anschlusskabel, 
Stromkabel und Netzteile. Verwendung anderer Kabel und Adapter kann zu einer Fehlfunktion 
oder ein Brand entstehen. Elektrische Geräte und Material Safety Law verbietet die 

Verwendung von UL-oder CSA-zertifizierte Kabel, UL oder CSA auf der Code für alle anderen 

elektrischen Geräte als Produkte von Supermicro nur bezeichnet gezeigt haben.

¡Advertencia! 
Al instalar el producto, utilice los cables de conexión previstos o designados, los cables y 
adaptadores de CA. La utilización de otros cables y adaptadores podría ocasionar un mal 
funcionamiento o un incendio. Aparatos Eléctricos y la Ley de Seguridad del Material prohíbe 

el uso de UL o CSA cables certificados que tienen UL o CSA se muestra en el código de 

otros dispositivos eléctricos que los productos designados por Supermicro solamente.

電源コードとACアダプター
製品を設置する場合、提供または指定された接続ケーブル、電源コードとACアダプターを使用下さ
い。 他のケーブルやアダプタを使用すると故障や火災の原因になることがあります。 電気用品安全
法は、ULまたはCSA認定のケーブル(UL/CSEマークがコードに表記)を  Supermicroが指定する製
品以外に使用することを禁止しています。

警告
安装此产品时,请使用本身提供的或指定的连接线,电源线和电源适配器.使用其它线材或适配
器可能会引起故障或火灾。除了Supermicro所指定的产品,电气用品和材料安全法律规定禁止
使用未经UL或CSA认证的线材。(线材上会显示UL/CSA符号)。

警告
安裝此產品時,請使用本身提供的或指定的連接線,電源線和電源適配器.使用其它線材或適配
器可能會引起故障或火災。除了Supermicro所指定的產品,電氣用品和材料安全法律規定禁止
使用未經UL或CSA認證的線材。(線材上會顯示UL/CSA符號)。

Warning! 

When installing the product, use the provided or designated connection 

cables, power cables and AC adaptors. Using any other cables and adaptors could 

cause a malfunction or a fire. Electrical Appliance and Material Safety Law prohibits 
the use of UL or  CSA -certified cables (that have  UL/CSA shown on the code) for any 

other electrical devices than products designated by Supermicro only.

Содержание SuperServer 5019S-WR

Страница 1: ...ce when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s i...

Страница 2: ...te for possible updates to the manual revision level Warnings Special attention should be given to the following symbols used in this manual Warning Indicates high voltage may be encountered when perf...

Страница 3: ...Connectors 39 Control Panel 43 Data Cables 45 Power Cables 45 4 3 Ports 46 Rear I O Ports 46 4 4 Jumpers 48 Explanation of Jumpers 48 4 5 LED Indicators 51 Chapter 5 Software 5 1 OS Installation 52 I...

Страница 4: ...r Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical S...

Страница 5: ...ions noted in Appendix B Main Parts List Description Part Number Quantity Passive Heatsink for 1U System SNK P0046P 1 4 cm Cooling Fan FAN 0156L4 or FAN 0086L4 4 Backplane BPN SAS3 815TQ P 1 Hot swap...

Страница 6: ...t maintains standby power To perform many maintenance tasks you must also unplug system before servicing Figure 1 1 Control Panel View 1 4 Server Chassis Features Control Panel The switches and LEDs l...

Страница 7: ...Below is a layout of the X11SSW F with jumper connector and LED locations shown See the table on the following page for descriptions For detailed descriptions pinout information and jumper settings r...

Страница 8: ...IO 1 2 Serial Link General Purpose I O Connection Headers for I SATA 3 0 Ports I SGPIO1 for I SATA2 3 I SGPIO2 for I SATA4 7 J23 M 2 Socket 3 supports 2260 2280 22110 for NVMe and SATA SSDs JD1 Speake...

Страница 9: ...5 Gb S USB 2 0 14 USB2 0 5 6 7 8 PCH 6 0 Gb S USB 2 0 LPC USB 1 0 5 4 RTL8211F CG 3 2 RJ45 SPI Temp Sensor TPM HEADER BIOS SPI AST2400 BMC 9 10 11 12 13 RMII NCSI COM1 Connector COM2 Header VGA CONN B...

Страница 10: ...se read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where heat...

Страница 11: ...the racks should be coupled together Always make sure the rack is stable before extending a server or other component from the rack You should extend only one server or component at a time extending t...

Страница 12: ...ded from the rack This prevents the server from coming completely out of the rack when you pull it out for servicing Figure 2 2 Installing the Rails Warning Stability hazard The rack stabilizing mecha...

Страница 13: ...iding the chassis into the rack and tightening the brackets to the rack See Figure 2 4 Figure 2 4 Installing the Server into a Telco Rack Figure 2 3 Installing the Server into a Rack Note Figure is fo...

Страница 14: ...a click 3 Depress the two buttons on the top of the chassis to release the top cover and at the same time push the cover away from you until it stops 4 Lift the top cover from the chassis to gain full...

Страница 15: ...processor inserted into the socket inspect the four corners of the CPU to make sure that it is properly installed and flush with the socket 6 Carefully press the processor load lever down until it loc...

Страница 16: ...up to 64GB of ECC DDR4 2133 1866 1600 1333 unbuffered UDIMM memory in four memory slots Populating two adjacent slots at a time with memory modules of the same size and type will result in interleave...

Страница 17: ...hassis cover to access the inside of the system 2 Remove the PCI slot shield on the chassis by releasing the locking tab 3 Insert the expansion add on card into the riser card 4 Secure the card with t...

Страница 18: ...without removing power from the system Removing a Hot Swap Drive Carrier 1 Push the release button on the carrier 2 Swing the handle fully out 3 Grasp the handle and use it to pull the drive carrier o...

Страница 19: ...mpening vibration levels The chassis provides two additional open fan housings where an additional system fan may be added for optimal cooling It is very important that the chassis top cover is instal...

Страница 20: ...g you can replace the failed module without powering down the system Removing the Power Supply You do not need to shut down the system to replace a power supply module The redundant feature will keep...

Страница 21: ...COM 3 COM 16 PS_ON 4 5V 17 COM 5 COM 18 COM 6 5V 19 COM 7 COM 20 Res NC 8 PWR_OK 21 5V 9 5VSB 22 5V 10 12V 23 5V 11 12V 24 COM 12 3 3V Required Connection Important To provide adequate power to the m...

Страница 22: ...rt 80 header is located at JTPM1 to provide TPM support and a Port 80 connection Use this header to enhance system performance and data security SGPIO Headers Two SGPIO Serial General Purpose Input Ou...

Страница 23: ...iggered via IPMI on the motherboard For more information on IPMI please refer to the IPMI User s Guide posted on our website at http www supermicro com UID Switch Pin Definitions Pin Definition 1 Grou...

Страница 24: ...13 to use UID switch OH Fan Fail LED Pin Definitions JF1 Pins Definition 7 Blue LED 8 OH Fan Fail LED OH Fan Fail Indicator Status State Definition Off Normal On Overheat Flashing Fan Fail LAN1 LAN2...

Страница 25: ...s USB Ports Two USB 2 0 ports USB0 1 and two USB 3 0 ports USB6 7 are located on the I O back panel The motherboard also has two front access USB 2 0 headers USB2 3 and USB4 5 and one front access USB...

Страница 26: ...conds 5 Remove the screwdriver or shorting device 6 Replace the cover reconnect the power cord s and power on the system Notes Clearing CMOS will also clear all passwords Do not use the PW_ON connecto...

Страница 27: ...rd Refer to the table below for jumper settings The default setting is BMC Enable BMC Enable Jumper Settings Jumper Setting Definition Pins 1 2 BMC Enabled Pins 2 3 Disabled 4 5 LED Indicators LAN1 2...

Страница 28: ...Windows OS Setup screen will display 3 From the Windows OS Setup screen press the Enter key The OS Setup will automatically load all device files and then continue with the Windows installation 4 Aft...

Страница 29: ...ith SuperDoctor 5 Management Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SuperDoctor 5 Management Server monitor...

Страница 30: ...built in We retain the option to include omit or change any of these text messages Settings printed in Bold are the default values A indicates a submenu Highlighting such an item and pressing the Ent...

Страница 31: ...evert to the default to the manufacture default settings Boot Feature Quiet Boot Use this feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to...

Страница 32: ...or more than 5 minutes The options are Enabled and Disabled Power Button Function This feature controls how the system shuts down when the power button is pressed Select 4_Seconds_Override for the use...

Страница 33: ...to reduce power consumption and heat dissipation The options are Disabled and Enabled Turbo Mode Select Enabled for processor cores to run faster than the frequency specified by the manufacturer The o...

Страница 34: ...mption The options are Disabled and Enabled Chipset Configuration Warning Setting the wrong values in the following features may cause the system to malfunc tion System Agent SA Configuration The foll...

Страница 35: ...or on your keyboard to change this value The default setting is 75 SLOT1 Slot Power Limit Scale Use this feature to select the scale used for the slot power limit value The options are 1 0x 0 1x 0 01x...

Страница 36: ...e to enable or disable peer memory write The options are Disabled or Enabled PCH SLOT1 PCI E 3 0 X8 SLOT1 ASPM Use this item to set the Active State Power Management ASPM level for a PCI E device Sele...

Страница 37: ...64 bit in the space above 4G Address The options are Enabled and Disabled CPU SLOT1 PCI E 3 0 X16 OPROM Use this feature to select which firmware type to be loaded for the add on card in this slot The...

Страница 38: ...The options are Enabled and Disabled Logical Device Settings This item displays the status of a serial part specified by the user Serial Port 2 Change Settings This feature specifies the base I O por...

Страница 39: ...y buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start sending data when the receiving buffer is empty The options are None and Hardwa...

Страница 40: ...ed terminal resolution support The options are Disabled and Enabled COM2 Legacy OS Redirection Resolution Use this feature to select the number of rows and columns used in Console Redirection for lega...

Страница 41: ...et to Enabled onbaord security devices will be enabled for TPM Trusted Platform Module support to enhance data integrity and network security Please reboot the system for a change on this setting to t...

Страница 42: ...displays the connection status MAC Address This item displays the MAC address for this computer Mac addresses are 6 two digit hexadecimal numbers Virtual MAC Address This item displays the Virtual MA...

Страница 43: ...Options SMBIOS Event Log Change this item to enable or disable all features of the SMBIOS Event Logging during system boot The options are Enabled and Disabled Erasing Settings Erase Event Log If No...

Страница 44: ...tem for the changes to take effect View SMBIOS Event Log This section displays the contents of the SMBIOS Event Log 6 5 IPMI Use this feature to configure Intelligent Platform Management Interface IPM...

Страница 45: ...ss Source This feature allows the user to select the source of the IP address for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system m...

Страница 46: ...nu allows the user to configure the following Key Management settings Provision Factory Default Keys Select Enabled to install the default Secure Boot keys set by the manufacturer The options are Disa...

Страница 47: ...options are Yes and No Append Key Select Yes to add the DBT from the manufacturer s defaults list to the existing DBT Select No to load the DBT from a file The options are Yes and No 6 7 Boot Use this...

Страница 48: ...are boot devices UEFI Boot Order 1 6 8 Save Exit Select the Exit tab from the BIOS setup utility screen to enter the Exit BIOS Setup screen Discard Changes and Exit Select this option to quit the BIO...

Страница 49: ...ture select Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore...

Страница 50: ...y communicated through a series of audible beeps The numbers on the fatal error list on the following page correspond to the number of beeps for the corresponding error All errors listed with the exce...

Страница 51: ...it den Gefahren elektrischer Schaltungen und den blichen Verfahren zur Vorbeugung vor Unf llen vertraut Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen berset...

Страница 52: ...DEZE INSTRUCTIES Installation Instructions Warning Read the installation instructions before connecting the system to the power source Warnung Vor dem Anschlie en des Systems an die Stromquelle die In...

Страница 53: ...che installatie Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 250V 20A Power Disconnection Warning Warnung Das System muss von allen Quellen der Energie und vom Netzanschluss...

Страница 54: ...dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Restricted Area Waarschuwi...

Страница 55: ...alleen verkregen worden door gebruik te maken van speciaal gereedschap slot en sleutel of andere veiligheidsmaatregelen Battery Handling Warnung Bei Einsetzen einer falschen Batterie besteht Explosion...

Страница 56: ...e unit Warnung Dieses Ger t kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Waarschuwing Deze eenheid kan mee...

Страница 57: ...enance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing Comply with Local and National Electrical Codes Warnung Die Installation...

Страница 58: ...rtencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales Waarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemmi...

Страница 59: ...nschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von...

Страница 60: ...appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bij het...

Страница 61: ...to house four SATA drives PCI Expansion Slots One Proprietary WIO R slot using RSC R1UW E8R riser card One Proprietary WIO L slot using RSC W 68 riser card One M 2 NGFF connector supports PCIe 3 0 x4...

Страница 62: ...EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Perchlorate Warning California Best Management Practices R...

Отзывы: