background image

SuperServer 4028GR-TR(T)(2) User's Manual 

2-6

Figure 2-3. Extending and Mounting the Outer Rails

1

1

1

2

1

3

1

4

21D01

L-min=676.00(26.61")(outer rail)

Installing the Outer Rails onto the Rack

Installing the Outer Rails

1.  Press upward on the locking tab at the rear end of the middle rail. 

2.  Push the middle rail back into the outer rail.

3.  Hang the hooks on the front of the outer rail onto the square holes on the front 

of the rack. If desired, use screws to secure the outer rails to the rack.

4. 

Pull out the rear of the outer rail, adjusting the length until it just fits within the 

posts of the rack. 

5.  Hang the hooks of the rear section of the outer rail onto the square holes on the 

rear of the rack. Take care that the proper holes are used so the rails are level. 
If desired, use screws to secure the rear of the outer rail to the rear of the rack. 

6.  Repeat for the other outer rail.

Stability hazard.

 The rack stabilizing mechanism must be in place, or the rack 

must be bolted to the floor before you slide the unit out for servicing. Failure to 

stabilize the rack can cause the rack to tip over.

Do not use a two post "telco" type rack.

Содержание SUPERSERVER 4028GR-TR

Страница 1: ...USER S MANUAL Revision 1 0c SUPERSERVER 4028GR TR 4028GR TRT 4028GR TR2 4028GR TRT2 125480 33 1 site https andpro ru 7 495 545 4870 email info andpro ru AND PDF...

Страница 2: ...any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits...

Страница 3: ...lities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities ftp ftp supermicro com Product safety info http www superm...

Страница 4: ...1 7 Chapter 2 Rack Installation 2 1 Unpacking the System 2 1 2 2 Preparing for Setup 2 1 Choosing a Setup Location 2 1 2 3 Warnings and Precautions 2 2 Rack Precautions 2 2 General Server Precautions...

Страница 5: ...tandardized Warning Statements 4 1 Warning Definition 4 1 Installation Instructions 4 4 Circuit Breaker 4 5 Power Disconnection Warning 4 6 Equipment Installation 4 8 Restricted Area 4 9 Battery Handl...

Страница 6: ...PCI E Daughter Board 5 12 5 7 Connector Definitions 5 13 Power Connectors 5 13 Control Panel Connectors 5 14 Rear Input Output Connections 5 17 Internal Headers 5 18 5 8 Jumper Settings 5 20 5 9 Onboa...

Страница 7: ...the Configuration Data 7 1 Starting the Setup Utility 7 2 7 2 Main Setup 7 2 7 3 Advanced Setup Configurations 7 4 7 4 Event Logs 7 37 7 5 IPMI 7 39 7 6 Security Settings 7 42 7 7 Boot Settings 7 45...

Страница 8: ...viii Notes...

Страница 9: ...air shroud MCP 310 41808 0B over PCI slots Two passive CPU heatsinks SNK P0048PS Storage Accessories One SAS backplane BPN SAS3 216A Twenty four hot swap drive carriers MCP 220 00047 0B Riser card RSC...

Страница 10: ...ECC 288 pin at 2400 2133 1866 1600 1333 MHz DIMMs up to 64 GB at 1 2V See Chapter 5 for details Serial ATA The motherboard supports a ten SATA 3 0 ports That is four I SATA two more I SATA with SuperD...

Страница 11: ...Ports 4 5 1 U P C 2 U P C SXB2 PCH 10G LAN Ports 4 5 SATA SATA3 SATA3 port2 port3 port1 port1 port2 port3 A 2 B 2 C 1 C 2 D 1 D 2 2133 DDR4 F 1 E 1 E 2 G 1 F 2 H 2 H 1 G 2 Ports 0 3 SATA D 3 C 3 B 3...

Страница 12: ...4028GR TR T 2 server uses the SC418GTS R4000P chassis System Power The chassis features a 2 2 redundant power supply system composed of four hot plug high efficiency power modules Storage Drives The c...

Страница 13: ...to the NVIDIA web site www nvidia com for details on Tesla GPUs The GPUs process complex image calculations and then route the data out through the VGA port on the motherboard NVIDIA K40 K80 GPUs hav...

Страница 14: ...Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl...

Страница 15: ...Avoid areas where heat electrical noise and electromagnetic fields are generated A nearby grounded power outlet is required The box your chassis was shipped in should include two sets of rail assembli...

Страница 16: ...being overextended Have a rack lift in place as a precaution in case the test fails In any instance of pulling the system from the rack always use a rack lift and follow all associated safety precauti...

Страница 17: ...sideration of equipment nameplate ratings should be used when addressing this concern Reliable Ground A reliable ground must be maintained at all times To ensure this the rack itself should be grounde...

Страница 18: ...efer to the installation instructions for your rack unit Note This rail will fit a rack between 26 5 and 36 4 deep Identifying the Inner Rack Rails The chassis package includes one pair of rack rail a...

Страница 19: ...f the chassis with the inner rail holes Make sure the rail faces outward so that it will fit with the rack s mounting bracket 2 Slide the rail toward the front of the chassis to hook the inner rail on...

Страница 20: ...outer rails to the rack 4 Pull out the rear of the outer rail adjusting the length until it just fits within the posts of the rack 5 Hang the hooks of the rear section of the outer rail onto the squa...

Страница 21: ...n on both sides You may have to depress the locking tabs while inserting When the server has been pushed completely into the rack the locking tabs should click into the locked position 3 If screws are...

Страница 22: ...the heavy chassis from the rack without assistance Be sure to have sufficient assistance supporting the chassis when removing it from the rack Use a lift Removing the Chassis from the Rack 1 Pull the...

Страница 23: ...The server includes a control panel on the front that houses power buttons and status monitoring lights The externally accessible hard drives display status lights The power supply displays status lig...

Страница 24: ...intains standby power To perform most maintenance tasks unplug the system to remove all power Reset The reset button is used to reboot the system 3 2 Control Panel Buttons The chassis includes two pus...

Страница 25: ...d red An overheat condition has occured This may be caused by cable congestion Blinking red 1Hz Fan failure check for an inoperative fan Blinking red 0 25Hz Power failure check for a non operational p...

Страница 26: ...uting of the cables and make sure all fans are present and operating normally 4 Verify that the heatsinks are installed properly 3 4 Drive Carrier LEDs The chassis includes externally accessible SAS S...

Страница 27: ...supply is on Solid Amber When illuminated indicates the power supply is plugged in and turned off or the system is off but in an abnormal state Blinking Amber When blinking this system power supply te...

Страница 28: ...SuperServer 4028GR TR T 2 User s Manual 3 6 Notes...

Страница 29: ...y certified technicians should attempt to install or configure components Read this chapter in its entirety before installing or configuring components in the Supermicro chassis Some warnings may not...

Страница 30: ...considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar...

Страница 31: ...k letsel kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaa...

Страница 32: ...lie en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de branc...

Страница 33: ...ert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuitos o sobrecorrientes de...

Страница 34: ...reift um Systemsbestandteile anzubringen oder zu entfernen Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing...

Страница 35: ...nentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enle...

Страница 36: ...arnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o...

Страница 37: ...stallation in Bereichen mit beschr nktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m gli...

Страница 38: ...same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een...

Страница 39: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 40: ...de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour supprimer toute tens...

Страница 41: ...del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circulent sur le fond de panier Prendre des pr cautions lors d...

Страница 42: ...electrical codes Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Ba...

Страница 43: ...ional laws and regulations Attention L quipement doit tre install conform ment aux normes lectriques nationales et locales Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lok...

Страница 44: ...eglamentos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme co...

Страница 45: ...s destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soien...

Страница 46: ...Adapter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r alle an...

Страница 47: ...utres appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bi...

Страница 48: ...4 20 SUPERSERVER 4028GR TR T 2 User s Manual Notes...

Страница 49: ...it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a grounded wrist strap designed to prevent Electrostatic Disch...

Страница 50: ...s they were originally after reconnecting them Make sure the red wires connect to the pin 1 locations See the layout in section 5 6 for connector locations Important Make sure the the cables do not co...

Страница 51: ...LAN Port 1 2 USB 3 0 Port 6 7 LAN Port 2 3 IPMI Dedicated LAN 8 VGA Port 4 USB 3 0 Port 7 9 UID Switch 5 USB 3 0 Port 8 5 3 Input Output Ports Figure 5 1 I O Ports 1 1 9 1 7 1 8 1 6 1 3 2 For X10DRG...

Страница 52: ...e only an Intel certified multi directional heatsink Avoid placing direct pressure to the top of the processor package Install the processor into the CPU socket before installing the heatsink Refer to...

Страница 53: ...edges will fit the socket OPEN1st IMPORTANT Caution You can only install the CPU into the socket in one direction Make sure that the CPU is properly inserted into the socket before closing the load pl...

Страница 54: ...and lock the Close 1st lever Push down and lock the lever labeled Open 1st OPEN1st OPEN1st Push down and lock the lever labeled Close 1st 9 Close and lock the Open 1st lever Engage the lip of the loa...

Страница 55: ...ully tightening all four screws Installing a CPU Heatsink Removing the Heatsink Caution We do not recommend removing the CPU or the heatsink If you do need to remove the heatsink please follow the ins...

Страница 56: ...ion Exercise care installing or removing DIMM modules to avoid damage Installing Memory Modules Insert the desired number of DIMMs into the memory slots starting with P1 DIMM 1A 1 Push the release tab...

Страница 57: ...2 E3 F3 G3 H3 Populating RDIMM LRDIMM DDR4 Memory Modules Type Ranks Per DIMM and Data Width DIMM Capacity GB Speed MT s Voltage V Slots per Channel SPC and DIMMs per Channel DPC 3 Slots per Channel 1...

Страница 58: ...JPW12 JPW4 LE1 LEDM1 I SGPIO1 I SGPIO2 S SGPIO JTPM1 JF1 FAN4 FAN8 FAN3 FAN7 FAN2 FAN5 FAN1 JSD2 JSD1 S SATA3 S SATA2 S SATA1 S SATA0 I SATA5 I SATA4 I SATA3 I SATA1 I SATA2 I SATA0 BT1 1G 10GMACCODE...

Страница 59: ...W3 7 JPW12 18 12V 8 pin power connectors JPW17 JPW18 white power connectors used for BPD HDDs only JSD1 JSD2 Power connector SATA DOM JTPM1 TPM Trusted Platform Module Port 80 header JVRM1 JVRM2 VRM 1...

Страница 60: ...aughter Board for 4028GR TR T J9 FAN25 FAN24 FAN23 FAN22 FAN21 LE5 LE17 LE16 LE15 LE14 LE13 LE12 LE3 LE9 LE11 LE10 LE2 LE8 LE7 LE6 LE4 BAR CODE CPU1 SLOT11 PCI E 3 0 X16 CPU1 SLOT10 PCI E 3 0 X16 CPU1...

Страница 61: ...hite JPW17 18 connectors are reserved for BPD HDD use only 12V 8 pin Power Connector Pin Definitions Pins Definition 1 through 3 12 4 through 8 Ground Figure 5 6 X10DRG O PCIE Daughter Board for 4028G...

Страница 62: ...round x Key Power On LED HDD LED NIC1 LED Link NIC2 LED Link OH Fan Fail UID LED PWR Fail LED Ground Ground 2 1 20 19 Control Panel Connectors Power Button Connector The PW_ON connector is on pins 1 a...

Страница 63: ...ition Off Normal On Overheat Flashing Fan Fail Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1 Refer to the table on the right for pin definitions PWR Fail LED Pin Defin...

Страница 64: ...a rack Power On LED The Power On LED connector is located on pins 15 and 16 of JF1 This connection is used to provide LED indication of power being supplied to the system See the table on the right fo...

Страница 65: ...n the X10DRG O In addition an IPMI_Dedicated LAN that supports Gigabit LAN is located above USB 4 5 ports on the rear I O shield All Ethernet ports accept RJ45 type cables Video Connection A video VGA...

Страница 66: ...19 LPCPD 20 LDRQ X Fan Header Pin Definitions Pin Definition 1 Ground 2 12V 3 Tachometer 4 Pulse Width Modulation Fan Headers The motherboard has eight system CPU fan headers Fans 1 8 All are 4 pin fa...

Страница 67: ...vided on the motherboard I SGPIO1 supports I SATA 0 3 I SGPIO2 supports I SATA 4 5 S SGPIO is used for S SATA 0 3 See the table on the right for pin definitions T SGPIO Pin Definitions Pin Definition...

Страница 68: ...lear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS 1 First pow...

Страница 69: ...Dog must also be enabled in BIOS Note When enabled the user must write their own application software to disable the Watch Dog Timer Watch Dog Jumper Settings Jumper Setting Definition Pins 1 2 Reset...

Страница 70: ...A dedicated IPMI LAN port is also located on the I O backplane The amber LED on the right indicates activity while the LED on the left indicates the speed of the connection See the table at right BMC...

Страница 71: ...d by the Intel PCH on the motherboard There are also four S SATA connectors S SATA0 3 supported by the Intel SCU I SATA4 5 colored in yellow are used with Supermicro SuperDOM Disk on Module connectors...

Страница 72: ...o Website at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and utilities After creating a CD DVD with the ISO files insert...

Страница 73: ...he program monitors system health information such as CPU temperature system voltages system power consumption fan speed and provides alerts via email or Simple Network Management Protocol SNMP SuperD...

Страница 74: ...used battery in the garbage or a public landfill Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly OR Note The SuperDo...

Страница 75: ...GTS R3200BP chassis The only tool required is a Phillips screwdriver Your system may require the installation of processors memory drives or expansion cards Other procedures presented in this chapter...

Страница 76: ...modules avoid touching their pins Put expansion cards and peripherals back into their antistatic bags when not in use For grounding purposes make sure your computer chassis provides excellent conduct...

Страница 77: ...TA HDDs only are recommended With an additional optional backplane it can support 48 drives Removing Hard Drives and their Carriers from the Hard Drive Bays 1 Press the release button on the drive car...

Страница 78: ...re are holes in the carrier marked SATA to aid in correct installation 3 Secure the drive to the carrier with four screws as illustrated below 4 Insert the drive carrier into its bay keeping the carri...

Страница 79: ...sinks start by shutting the system down and disconnecting the AC power cord 1 Depress the two release buttons on both sides of the cover 2 Slide the cover toward the rear of the chassis 3 Lift the cov...

Страница 80: ...n Installing Expansion Cards 1 Power down the system as described in Section 6 2 and open the chassis cover 2 Remove the screw holding the chassis slot shield in place 3 Insert the expansion card into...

Страница 81: ...right side and remove the GPU retention bracket 2 Noting the front and rear sides of the air shroud insert the sides of the air shroud between the chassis and GPU1 and GPU8 Insert the interior air sh...

Страница 82: ...led Never run the server for an extended period of time with the chassis cover open 2 Press the fan housing lever to unlock the fan from the bracket 3 While applying pressure to fan housing lever gent...

Страница 83: ...le can be replaced without powering down the system Replace with the same model Replacement modules can be ordered directly from Supermicro An amber light on the power supply is illuminated when the p...

Страница 84: ...6 10 SUPERSERVER 4028GR TR T 2 USER S MANUAL Notes...

Страница 85: ...ea reserved for informational text When an option is selected in the left frame it is highlighted in white Often informational text will accompany it Note The AMI BIOS has default informational messag...

Страница 86: ...ur system has a BIOS related issue Flashing the wrong BIOS can cause irreparable damage to the system In no event shall the manufacturer be liable for direct indirect special incidental or consequenti...

Страница 87: ...keyboard and press Enter The time is entered in HH MM SS format The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 Supermicro X10DRG O T BIOS Version This item displays the ve...

Страница 88: ...to the manufacturer s default setting Boot Feature Quiet Boot Use this feature to select the screen display between POST messages or the OEM logo at bootup Select Disabled to display the POST messages...

Страница 89: ...vice after its initial boot failure Select Legacy Boot to allow the BIOS to automatically reboot the system from a Legacy boot device after its initial boot failure The options are Disabled Legacy Boo...

Страница 90: ...tic Interference caused by the components whenever needed The options are Disable and Enable Hyper Threading All Select Enable to support Intel s Hyper threading Technology to enhance CPU performance...

Страница 91: ...eboot the system for changes on this setting to take effect Please refer to Intel s website for detailed information DCU Data Cache Unit Streamer Prefetcher Available when supported by the CPU If set...

Страница 92: ...nable Chipset Configuration Warning Please set the correct settings for the items below A wrong configuration setting may cause the system to malfunction North Bridge This feature allows the user to c...

Страница 93: ...frequencies in relation to the magnitude of very low frequencies to improve the overall signal to noise ratio by reducing the level of all signals data bits transmitted except the first one acting as...

Страница 94: ...ified by the user Select Auto for the BIOS ROM to automatically discard a PCI E port specified by the user when there is no HP compatible device connected to this port or when there is no error detect...

Страница 95: ...user The options are Disable and Enable Corr Err Correctable Error Over Select Enable to force correctable error propagation to the II0 core error logic for the port specified by the user The options...

Страница 96: ...arent Bridge PCIe Port D Port 3A only Select Transparent Bridge to configure the device installed on a PCI slot specified by the user as a transparent bridge TB device Select NTB Non Transparent Bridg...

Страница 97: ...specified by the user The options are Disable and Enable PCI E Port Link Use this feature to disable the physical link connected to a PCI E port specified by a user so that no training will take place...

Страница 98: ...will not put its transmitter in the L0s state The default setting is Disable PM ACPI Mode Select Enable to generate an _HPGPE message on a PM ACPI event Select Disable to generate an MSI message The...

Страница 99: ...ed on a PCI slot specified by the user as a non transparent bridge TB device used to connect to another TB device The options are Transparent Bridge NTB to NTB and NTB to RP Hide Port Use this feature...

Страница 100: ...nable and Disable Interrupt Remapping Select Enable for Interrupt Remapping support to enhance system performance The options are Enable and Disable QPI Quick Path Interconnect Configuration QPI Gener...

Страница 101: ...ble Memory Configuration Enforce POR Select Enable to enforce POR restrictions on memory frequency and voltage programming The options are Enabled and Disabled Memory Frequency Use this feature to set...

Страница 102: ...MM module as detected by the BIOS P1 DIMMA1 A2 A3 P1 DIMMB1 B2 B3 P1 DIMMC1 C2 C3 P1 DIMMD1 D2 D3 P2 DIMME1 E2 E3 P2 DIMMF1 F2 F3 P2 DIMMG1 G2 G3 and P2 DIMMH1 H2 H3 Memory RAS Reliability Availabilit...

Страница 103: ...emand Scrub Demand Scrubbing is a process that allows the CPU to correct correctable memory errors found on a memory module When the CPU or I O issues a demand read command and the read data from memo...

Страница 104: ...d and Enabled USB 3 0 Support Select Enabled for USB 3 0 support The options are Smart Auto Auto Enabled Disabled and Manual SATA Configuration When this submenu is selected the AMI BIOS automatically...

Страница 105: ...1 set this item to allow the PCH to initialize the device The options are Disabled and Enabled Port 0 Port 5 SATA Device Type Use this item to specify if the SATA port specified by the user should be...

Страница 106: ...ice Select Both to boot the system either from a SATA RAID device or from an sSATA RAID device Please note that the option Both is not supported by the Windows Server 2012 R2 OS The options are None S...

Страница 107: ...ill display Support Aggressive Link Power Management When this item is set to Enabled the SATA AHCI controller manages the power usage of the SATA link The controller will put the link to a low power...

Страница 108: ...ay Support Aggressive Link Power Management When this item is set to Enabled the SATA AHCI controller manages the power usage of the SATA link The controller will put the link to a low power state whe...

Страница 109: ...be connected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive Server ME Management Engine Configuration This feature displays the following system ME c...

Страница 110: ...PERR PCI PCI E Parity Error SERR System Error runtime error reporting for a PCI PCI E slot The options are Disabled and Enabled Above 4G Decoding Available if the system supports 64 bit PCI decoding...

Страница 111: ...Option ROM support to boot the computer using a device installed on slot 1 The options are Disabled Legacy and EFI CPU2 Slot 2 PCI E x16 OPROM Option ROM Select Enabled to enable Option ROM support to...

Страница 112: ...CPU1 Slot 11 PCI E x16 OPROM Option ROM Select Enabled to enable Option ROM support to boot the computer using a device installed on slot 5 The options are Disabled Legacy and EFI Onboard Video OPROM...

Страница 113: ...a serial port specified The options for Serial Port 1 are Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 10 11 12 IO 2F8h IRQ 3 4 5 6 7 10 11 12 IO 3E8h IRQ 3 4 5 6 7 10 11 12 and IO 2E8h IRQ 3 4 5 6 7 10 1...

Страница 114: ...ions are 7 Bits and 8 Bits Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits...

Страница 115: ...h is a terminal emulator designed for the Windows OS The options are VT100 LINUX XTERMR6 SCO ESCN and VT400 Redirection After BIOS Post Use this feature to enable or disable legacy Console Redirection...

Страница 116: ...ct data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits is odd Sele...

Страница 117: ...disable legacy Console Redirection after BIOS POST Power On Self Test When this feature is set to BootLoader legacy Console Redirection is disabled before booting the OS When this feature is set to A...

Страница 118: ...rt Select ANSI to use the extended ASCII character set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are VT100 VT100 VT UTF8 and ANSI Bits per second...

Страница 119: ...reboot to carry out a pending TPM operation The options are 0 Enable Take Ownership Disable Take Ownership and TPM Clear Note Your system will reboot to carry out a pending TPM operation Current Stat...

Страница 120: ...niform Memory Access support to enhance system performance The options are Disabled and Enabled iSCSI Configuration This item displays iSCSI configuration information iSCSI Initiator Name This item di...

Страница 121: ...stem boot The options are Disabled and Enabled Runtime Error Logging Support Select Enable to support Runtime Error Logging The options are Disabled and Enabled Erasing Settings Erase Event Log Select...

Страница 122: ...Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This item is used to deter...

Страница 123: ...evision This item indicates the IPMI firmware revision used in your system Status of BMC This item indicates the status of the onboard BMC Baseboard Management Controller System Event Log Enabling Dis...

Страница 124: ...ble Firmware Interface Status Codes Error Codes or Progress Codes The options are Disabled Both Error code and Progress code BMC Network Configuration The following items will be displayed Update IPMI...

Страница 125: ...mber is separated by dots and it should not exceed 255 Station MAC Address This item displays the Station MAC address for this computer Mac addresses are 6 two digit hexadecimal numbers Gateway IP Add...

Страница 126: ...efore the user entering the BIOS setup utility The length of the password should be from 3 characters to 20 characters long User Password Use this feature to set the user password which is required to...

Страница 127: ...elete PK Select Yes to confirm deletion of the Platform Key PK from the NVRAM Non Volatile RAM Set New PK Select Yes to load the manufacture_default platform keys for your system Select No to load the...

Страница 128: ...atabase timer will be set in the NVRAM Non Volatile RAM Append DBT DataBase Timer Select Yes to load the new database timer from the manufacture defaults Select No to load the new database timer from...

Страница 129: ...device to be used for system boot The options are LEGACY UEFI and DUAL Fixed Boot Order Priorities This option prioritizes the order of bootable devices from which the system will boot Press Enter on...

Страница 130: ...e to add to the boot priority list Path for Boot Option Select the device path the file system for the new boot device to use Create After selecting a boot device to add and the path for this new devi...

Страница 131: ...Boot Option 1 Boot Order 2 Boot Order 3 Boot Order 4 Boot Order 5 Boot Order 6 Boot Order 7 Boot Order 8 Boot Order 9 Boot Order 10 Boot Order 11 Boot Order 12 Boot Order 13 Boot Order 14 Boot Order 1...

Страница 132: ...r Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility and reboot the computer for the new system configuration parameters...

Страница 133: ...er Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from th...

Страница 134: ...7 50 SuperServer 4028GR TR T 2 User s Manual Notes...

Страница 135: ...system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the cor...

Страница 136: ...A 2 SUPERSERVER 4028GR TR T 2 User s Manual Notes...

Страница 137: ...mory Note Refer to Section 5 5 for details on installation Check the Supermicro website www supermicro com for the latest memory support information SATA Drive Bays Twenty four hot swap drive bays to...

Страница 138: ...g Environment Operating Temperature 10 to 35 C 50 to 95 F Non operating Temperature 40 to 70 C 40 to 158 F Operating Relative Humidity 8 to 90 non condensing Non operating Relative Humidity 5 to 95 no...

Страница 139: ...B 3 Appendix B System Specifications Notes...

Страница 140: ...perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such...

Отзывы: