background image

USER’S MANUAL 

Revision 1.0

SuperServer

®

2049U-TR4

Содержание SuperServer 2049U-TR4

Страница 1: ...USER S MANUAL Revision 1 0 SuperServer 2049U TR4...

Страница 2: ...operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may ca...

Страница 3: ...sary drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities ftp ftp supermicro com Product safety info...

Страница 4: ...ing a Setup Location 16 Rack Precautions 16 Server Precautions 17 Rack Mounting Considerations 17 Ambient Operating Temperature 17 Airflow 17 Mechanical Loading 17 Circuit Overloading 18 Reliable Grou...

Страница 5: ...2 Removing the Processor Heatsink Module 33 3 4 Memory Support and Installation 34 Memory Support 34 DIMM Population Requirements for the 81xx 61xx 51xx series Processors 35 DIMM Installation 39 DIMM...

Страница 6: ...on 67 Starting the Setup Utility 67 6 2 Main Menu 68 6 3 Advanced Settings Menu 69 6 4 Event Logs 97 6 5 IPMI 99 6 6 Security Settings 102 6 7 Boot Settings 105 6 8 Save Exit 108 Appendix A BIOS Error...

Страница 7: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermi...

Страница 8: ...R 1 Riser Card RSC R2UW 4E8 1 2U Passive Standard Riser Card with two PCI E 3 0 x16 Slots RSC S2 66 2 2U Ultra Riser with 4 GbE ports and 2 PCI E x16 3 0 Intel i350 Add on Card AOC 2UR66 I4G 1 Black g...

Страница 9: ...Refer to the block diagram on page 18 to determine which slots or devices may be affected Socket Type Socket P0 LGA3647 Memory Integrated memory controller supports up to 6 TB of DDR4 3DS LRDIMM LRDIM...

Страница 10: ...used to reboot the system 3 Power LED Indicates power is being supplied to the system power supply This LED should normally be illuminated when the system is operating 4 HDD LED Indicates activity on...

Страница 11: ...Continuously on and red An overheat condition has occured This may be caused by cable congestion Blinking red 1Hz Fan failure check for an inoperative fan Solid blue Local UID has been activated Use...

Страница 12: ...es are supported 2 Expansion Slots Up to eleven 11 PCI E expansion cards are supported seven external four internal 3 I O Ports The I O port rear panel is located here See Chapter 4 for details Figure...

Страница 13: ...4B USB0 1 CPU1_PORT2 SXB3C CPU1_PORT1 SXB3B VGA UID COM1 I SATA0 3 S SATA0 3 I SATA4 7 USB 4 3 0 USB 2 3 3 0 IPMI_LAN CPU2_PORT2 CPU2_PORT1 CPU1 BACKPLANE POWER GPU POWER P1_DIMMB1 P1_DIMMC1 P1_DIMMB2...

Страница 14: ...header JTPM1 Trusted Platform Module Port 80 connector SXB1A SXB1B SXB1C WIO 2x16 PCI E 3 0 slot for CPU2 Port1 CPU2 Port2 J18 J19 J20 SXB2 WIO x8 PCI E 3 0 slot for CPU2 Port3 SXB3A SXB3B SXB3C Ultra...

Страница 15: ...IMM UPI UPI1 CPU3 PE1 PE2 PE3 X2 X2 X2 X2 UPI1 UPI0 UPI0 UPI1 UPI1 UP0 CPU1 PE3 x16 CPU1 PE2 x16 CPU1 PE3 x8 2 CPU2 PE1 x16 CPU2 PE2 x16 CPU2 PE3 x8 2 CPU4 PE2 x16 CPU3 PE2 x16 CPU4 PE2 x16 CPU1 PE3 x...

Страница 16: ...efore you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic f...

Страница 17: ...power supply modules to cool before touching them When not servicing always keep the front door of the rack and all covers panels on the servers closed to maintain proper cooling Rack Mounting Consid...

Страница 18: ...ention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit...

Страница 19: ...es two rail assemblies Each assembly consists of three sections An inner rail that secures directly to the chassis an outer rail that secures to the rack and a middle rail which extends from the outer...

Страница 20: ...of the rack when the chassis is pulled out for servicing To mount the rail onto the chassis first release the inner rail from the outer rails Releasing Inner Rail from the Outer Rails 1 Pull the inner...

Страница 21: ...e hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassis until the quick release bracket snaps into place securing the rail to...

Страница 22: ...tip over Figure 2 5 Extending and Mounting the Outer Rails Installing the Outer Rails onto the Rack Installing the Outer Rails 1 Press upward on the locking tab at the rear end of the middle rail 2 Pu...

Страница 23: ...recommendations printed on the rails Installing the Chassis into a Rack 1 Extend the outer rails as illustrated above 2 Align the inner rails of the chassis with the outer rails on the rack 3 Slide t...

Страница 24: ...has completely shut down disconnect the AC power cord s from the power strip or outlet If your system has more than one power supply remove the AC power cords from all power supply modules 3 Disconnec...

Страница 25: ...ning Except for short periods of time do not operate the server without the cover in place The chassis cover must be in place to allow for proper airflow and to prevent overheating Figure 3 1 Removing...

Страница 26: ...e cover is on the CPU socket and none of the socket pins are bent If they are contact your retailer When handling the processor avoid touching or placing direct pressure on the LGA lands gold contacts...

Страница 27: ...ier Assembly The processor carrier assembly contains the Intel Xeon Non Fabric Non F processor and a processor carrier 1 Plastic Protective Cover 2 CPU Socket 1 Non F Processor 2 Processor Carrier Ove...

Страница 28: ...Processor Heatsink Module The Processor Heatsink Module PHM contains a heatsink a processor carrier and the Intel Xeon Non Fabric Non F processor 1 Heatsink with Thermal Grease 2 Processor Carrier 3...

Страница 29: ...s below 2 Using the triangles as a guide carefully align and place Point A of the processor into Point A of the carrier Then gently flex the other side of the carrier for the processor to fit into Poi...

Страница 30: ...he processor carrier assembly so the processor s gold contacts are facing up then align the triangle on the assembly with hole 1 of the heatsink Press the processor carrier assembly down The plastic c...

Страница 31: ...protective cover installed on the CPU socket Remove it from the socket to install the Processor Heatsink Module PHM Gently pull up one corner of the plastic protective cover to remove it CPU Socket wi...

Страница 32: ...th a T30 Torx bit screwdriver gradually tighten screws 1 4 to assure even pressure The order of the screws is shown on the label on top of the heatsink To avoid damaging the processor or socket do not...

Страница 33: ...the CPU socket CPU Socket Removing the Processor Heatsink Module Before removing the processor heatsink module PHM from the motherboard unplug the AC power cord from all power supplies after shutting...

Страница 34: ...DIMM in the black slot if 2DPC memory configuration is used 3 Using unbalanced memory topology by populating two DIMMs in one channel while populating one DIMM in another channel will result in reduce...

Страница 35: ...ons Parameters Possible Values Number of Channels 1 2 3 4 5 or 6 Number of DIMMs per Channel 1DPC 1 DIMM Per Channel or 2DPC 2 DIMMs Per Channel DIMM Type RDIMM w ECC LRDIMM 3DS LRDIMM DIMM Constructi...

Страница 36: ...gle Rank Single Rank DDR1 None or same as DDR0 None or same as DDR0 None or same as DDR0 DDR2 None or same as DDR1 excludes DIMM 1 in 5DIMM configurations None or same as DDR1 excludes DIMM 1 in 5DIMM...

Страница 37: ...x8 DIMMs DDR Channel 0 1 2 DIMM0 is populated with identical DIMMs DDR Channel 0 1 DIMM1 is populated with identical DIMMs 1 SVLS 6 x8 DIMMs Populate 2 DIMMs per DDR channel x SVLS DIMM Population wi...

Страница 38: ...s DDR Channel 0 1 DIMM1 is populated with identical DIMMs 1 Y 6 x4 DIMMs Populate 2 DIMMs per DDR channel x Y DIMM Population within an IMC Note Non equal in rank pair of x4 DIMMs 1 pair of DIMMs DDR0...

Страница 39: ...3 0 IPMI_LAN CPU2_PORT2 CPU2_PORT1 CPU1 BACKPLANE POWER GPU POWER P1_DIMMB1 P1_DIMMC1 P1_DIMMB2 P1_DIMMC2 P1_DIMMA1 P1_DIMMA2 WIO 2x16 PCI E 3 0 PCI E 3 0 RSC 56 Lanes PCI E 3 0 RSC 48 Lanes Ultra IO...

Страница 40: ...chanical Electrical 1 Double width full height full length x16 CPU1 2 Double width full height full length x16 CPU1 3 Low profile half length x8 CPU2 4 Full height full length x8 CPU2 5 Full height fu...

Страница 41: ...cards are AOC 2UR66 I4G supports two full height full length x16 expansion cards 1 2 RSC R2UW 4E8 supports four full height x8 expansion cards 4 7 RSC R1UW E8R supports one low profile x8 expansion ca...

Страница 42: ...by flipping up its riser cage release tab as pictured in Figures 6 9 3 Insert the expansion card s into the riser card slot s 4 Reinstall the riser card into the serverboard expansion slot while alig...

Страница 43: ...the cover from the chassis 2 To access the riser card remove the screw on the side of the chassis and lift out the riser card 3 Insert the expansion card s into the riser card slot s 4 Reinstall the r...

Страница 44: ...with the positive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully Do not damage the battery in any way a damaged battery may release ha...

Страница 45: ...o simplify their installation and removal from the chassis System power may remain on when removing carriers with drives installed These carriers also help promote proper airflow for the drive bays Fo...

Страница 46: ...SuperServer 2049U TR4 User s Manual 46 1 2 Figure 3 9 Removing a Drive Carrier...

Страница 47: ...le swapping hard drives do not operate the server without the carriers in the drive bays Figure 3 10 Removing a Dummy Drive from a Carrier Installing a Drive into the Carrier 1 Install a new drive int...

Страница 48: ...e support Red Blinking at 4 Hz Identify drive for SAS SATA NVMe with RSTe support Green Solid On Safe to remove NVMe device Amber Blinking at 1 Hz Attention state do not remove NVMe device System Cool...

Страница 49: ...remove the cover from the chassis 3 Unplug the fan wiring from the serverboard 4 Press the fan release tab to lift the failed fan from the chassis 5 Place the new fan into the vacant space in the hous...

Страница 50: ...onsisting of two power modules They have an auto switching capability which enables them to automatically sense and operate at a 100V 240V input voltage If either of the two power supply modules fail...

Страница 51: ...failed power supply module 2 Press the release tab on the power supply module as illustrated 3 Use the handle to pull the module straight out of the chassis 4 Replace the failed module with an identic...

Страница 52: ...1 PSU2 are located on J24 J25 on the motherboard Connect these connectors to your power supply to provide power to your system See the layout drawing below for the locations of PSU1 and PSU2 12V 8 pin...

Страница 53: ...onnect a Trusted Platform Module TPM Port 80 which is available from a third party vendor TPM Port 80 is a security device which supports encryption and authentication in hard drives It allows the mot...

Страница 54: ...3 Ground I SATA 3 0 and S SATA 3 0 Ports The X11QPH has eight I SATA 3 0 ports I SATA0 3 I SATA4 7 and six S SATA S SATA0 3 S SATA4 S SATA5 on the motherboard The I SATA ports are supported by the Int...

Страница 55: ...JWD1 JPME1 JL1 JBT1 JRK1 JUSB2 BMC_HB _LED1 JF1 JSTBY1 P3_DIMMF1 P3_DIMMD2 P3_DIMMD1 P3_DIMME2 P3_DIMME1 P2_DIMMA2 P2_DIMMA1 P2_DIMMB2 P2_DIMMB1 P2_DIMMC2 P2_DIMMC1 P2_DIMMD2 P2_DIMMD1 P2_DIMME2 P2_D...

Страница 56: ...UID switch the UID LED indicator will be turned on Press the UID switch again to turn off the LED The UID Indicator provides easy identification of a system unit that may be in need of service Note U...

Страница 57: ...access Cables are not included Back Panel USB 2 3 3 0 Pin Definitions Pin Definition Pin Definition A1 VBUS B1 Power A2 D B2 USB_N A3 D B3 USB_P A4 GND B4 GND A5 Stda_SSRX B5 USB3_RN A6 Stda_SSRX B6...

Страница 58: ...3 CPU4 SXB2 SXB1B SXB1A SXB4A SXB4B USB0 1 CPU1_PORT2 SXB3C CPU1_PORT1 SXB3B VGA UID COM1 I SATA0 3 S SATA0 3 I SATA4 7 USB 4 3 0 USB 2 3 3 0 IPMI_LAN CPU2_PORT2 CPU2_PORT1 CPU1 BACKPLANE POWER GPU PO...

Страница 59: ...Button connection is located on pins 3 and 4 of JF1 Attach it to a hardware reset switch on the computer case to reset the system Refer to the table below for pin definitions Fan Fail and UID LED Con...

Страница 60: ...D connection is located on pins 13 and 14 of JF1 Attach a cable to pin 14 to show hard drive activity status Refer to the table below for pin definitions HDD LED Pin Definitions JF1 Pins Definition 13...

Страница 61: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearin...

Страница 62: ...tings Manufacturer Mode Jumper Settings Jumper Setting Definition Pins 1 2 Normal Pins 2 3 ME Recovery Watch Dog JWD1 controls the Watch Dog function Watch Dog is a monitor that can reboot the system...

Страница 63: ...n BMC is functioning normally See the table below for the LED status Onboard Power LED Indicator LED Color Definition Green Blinking BMC Normal Onboard Power LED The Onboard Power LED is located at LE...

Страница 64: ...port on the system Note for older legacy OS s please use a method to slipstream the drivers 3 Select the partition on the drive in which to install Windows 4 Browse the USB folder for the proper driv...

Страница 65: ...er option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and utilities to your hard dr...

Страница 66: ...octor 5 Management Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SuperDoctor 5 Management Server monitors HTTP FTP...

Страница 67: ...1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be con...

Страница 68: ...he system date and time Highlight System Date or System Time using the arrow keys on the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in Day MM DD YYYY...

Страница 69: ...item displays the default speed of the memory modules installed in the system 6 3 Advanced Settings Menu Use the arrow keys to select the Advanced submenu and press Enter to access the submenu items W...

Страница 70: ...led and Enabled Interrupt 19 Trap Capture Interrupt 19 is the software interrupt that handles the boot disk function When this item is set to Immediate the ROM BIOS of the host adaptors will capture I...

Страница 71: ...er On for the system power to be turned on after a power loss Select Last State to allow the system to resume its last power state before a power loss The options are Power On Stay Off and Last State...

Страница 72: ...em The options are Unlock Enable and Unlock Disable Hardware Prefetcher Available when supported by the CPU If this feature is set to Enable the hardware prefetcher will prefetch streams of data and i...

Страница 73: ...ssipation Please refer to Intel s website for detailed information The options are Disable and Enable EIST PSD Function Available when SpeedStep is set to Enable Use this feature to configure the proc...

Страница 74: ...es is turned off The options are Auto Enable and Disable Enhanced Halt State C1E Select Enable to enable Enhanced Halt State support which will significantly reduce the CPU s power consumption by mini...

Страница 75: ...ict The options are Topology Precedence and Feature Precedence Link L0p Enable Select Enable to enable Link L0p The options are Disable Enable and Auto Link L1 Enable Select Enable to enable Link L1 L...

Страница 76: ...CD_L Relaxation If this feature is set to Enable SPD Serial Presence Detect will override tCCD_L Column to Column Delay Long or Command to Command Delay Long on the column side If this feature is set...

Страница 77: ...e when memory mirror mode is enabled Correctable Error Threshold Use this item to enter the threshold value for correctable memory errors The default setting is 10 SDDC Plus One Select Enable for SDDC...

Страница 78: ...2 This feature configures the PCI E Bifuraction setting for a PCI E port specified by the user The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto IOU2 IIO PCIe Br3 This feature configures the PC...

Страница 79: ...re configures the PCI E Bifuraction setting for a PCI E port specified by the user The options are x16 and Auto MCP1 IIO PCIe Br5 This feature configures the PCI E Bifuraction setting for a PCI E port...

Страница 80: ...O PCIe Br5 This feature configures the PCI E Bifuraction setting for a PCI E port specified by the user The options are x16 and Auto PCI E Completion Timeout Disable Select Enable to enable PCI E Comp...

Страница 81: ...e TPL requests that will allow the hints to be sent to help facilitate and optimize the processing of certain transactions in the system memory The options are Enable and Disable Relaxed Ordering Sele...

Страница 82: ...cal interrupts The options are Enable and Disable Coherency Support Non Isoch Select Enable for the Non Iscoh VT d engine to pass through DMA Direct Memory Access to enhance system performance The opt...

Страница 83: ...Select Yes to disable the PCI E Completion Time out settings The options are Yes No and Per Port South Bridge The following South Bridge information will display USB Module Version USB Devices Legacy...

Страница 84: ...ence of the SATA devices that are supported by the Intel PCH chip and displays the following items SATA Controller This item enables or disables the onboard SATA controller supported by the Intel PCH...

Страница 85: ...item to allow the SATA device installed on the SATA port specified by the user to start a COMRESET initialization The options are Enable and Disable SATA Device Type Use this item to specify if the d...

Страница 86: ...nd Legacy sSATA Port 0 sSATA Port 5 Hot Plug Select Enable to support Hot plugging for the device installed on an sSATA port selected by the user which will allow the user to replace the device instal...

Страница 87: ...set the maximum size for a read request for a PCI E device to enhance system performance The options are Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes and 4096 Bytes MMCFG Base This feature...

Страница 88: ...pv6 HTTP boot support If this feature is disabled it will not create the Ipv6 HTTP boot option The options are Enabled and Disabled PXE Boot Wait Time Use this feature to select the wait time to press...

Страница 89: ...den when Serial Port 1 is set to Disabled Change Settings This feature specifies the base I O port address and the Interrupt Request address of Serial Port 2 Select Auto for the BIOS to automatically...

Страница 90: ...t to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits is odd Select None if you do not want to send a parity bit with your data...

Страница 91: ...or COM2 SOL Select Enabled to use the SOL port for Console Redirection The options are Enabled and Disabled If the item above set to Enabled the following items will become available for user s config...

Страница 92: ...2 Flow Control Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full...

Страница 93: ...s are Disabled and Enabled If the item above set to Enabled the following items will become available for user s configuration EMS Console Redirection Settings Out of Band Management Port The feature...

Страница 94: ...the Windows Hardware Error Architecture WHEA platform and provide a common infrastructure for the system to handle hardware errors within the Windows OS environment to reduce system crashes and to en...

Страница 95: ...he list of public keys During system boot the platform firmware uses this trusted public key to verify a digital signature in an attempt to manage and control the security of the platform firmware use...

Страница 96: ...pport to enhance system security and data integrity The options are Disabled and Enabled Note 1 If the option for this item TXT Support is set to Enabled be sure to disable EV DFX Device Function On H...

Страница 97: ...vent Log Select Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Enabled and Disabled Erasing Settings Erase Event Log Select Enabled to erase all error...

Страница 98: ...tes the multiple event counter should wait before generating a new event log Enter a number between 0 to 99 The default setting is 60 Note Please reboot the system for the changes to take effect Custo...

Страница 99: ...formation will display IPMI Firmware Revision This feature indicates the IPMI firmware revision used in your system Status of BMC This feature indicates the status of the BMC Baseboard Management Cont...

Страница 100: ...codes and progress codes The options are Disabled Both Error code and Progress code Note After making changes on a setting be sure to reboot the system for the changes to take effect BMC Network Conf...

Страница 101: ...Use this feature to configure the IPMI LAN mode setting The options are Dedicated Shared and Failover VLAN Support Select Enabled for IPMI VLAN support The options are Disabled and Enabled Configurati...

Страница 102: ...The length of the password should be from 3 characters to 20 characters long User Password Use this feature to set the user password which is required to enter the BIOS setup utility The length of the...

Страница 103: ...on Factory Default Keys Select Enabled to install all manufacturer default keys to configure the following system security settings The options are Enabled and Disabled Install Factor Default Keys Sel...

Страница 104: ...are Set New and Append Secure Boot Variable Size Key Key Sources The options are Save to File Set New and Erase Forbidden Signatures This feature allows the user to enter and configure a set of value...

Страница 105: ...Boot Order Priorities This feature prioritizes the order of a bootable device from which the system will boot Press Enter on each entry from top to bottom to select devices When the item above Boot Mo...

Страница 106: ...e set press Enter to create the new boot option in the boot priority list Delete Boot Option Use this feature to select a boot device to delete from the boot priority list Delete Boot Option Use this...

Страница 107: ...t the target boot driver to delete from the boot priority list Hard Disk Drive BBS Priorities Boot Option 1 5 Network Drive BBS Priorities Boot Option 1 USB Key Drive BBS Priorities Boot Option 1 UEFI...

Страница 108: ...uter Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utili...

Страница 109: ...faults To set this feature select Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this...

Страница 110: ...or occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list on the...

Страница 111: ...com support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnost...

Страница 112: ...112 SuperServer 2049U TR4 User s Manual...

Страница 113: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis The...

Страница 114: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 115: ...en dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan h...

Страница 116: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 117: ...es del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l insta...

Страница 118: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 119: ...bels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment War...

Страница 120: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 121: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...

Страница 122: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 123: ...anbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All con...

Страница 124: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 125: ...vertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques ci...

Страница 126: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 127: ...le elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordi...

Страница 128: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 129: ...stornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient to...

Страница 130: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...

Страница 131: ...le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto uti...

Страница 132: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Страница 133: ...Supports up to eleven 11 PCI Express 3 0 expansion cards by means of four riser cards seven external four internal two can be double width GPUs Motherboard X11QPH Chassis SC218UTS R1K62P 2U Rackmount...

Страница 134: ...EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Perchlorate Warning California Best Management Practices R...

Страница 135: ...ry codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the system power is turned on the recovery block codes execute first Once this process is complete...

Страница 136: ...e into the Root directory of a USB device or a writable CD DVD Note If you cannot locate the Super ROM file in your drive disk visit our website at www supermicro com to download the BIOS package Extr...

Страница 137: ...own above displays use the arrow keys to select the item Proceed with flash update and press the Enter key You will see the BIOS recovery progress as shown in the screen below Note Do not interrupt th...

Страница 138: ...change the device directory path Go to the directory that contains the BIOS package you extracted earlier from Step 6 Enter flash nsh BIOSname at the prompt to start the BIOS update process Note Do no...

Страница 139: ...unplug the AC power cable from the power supply clear CMOS and plug the AC power cable in the power supply again to power on the system 10 Press Del continuously to enter the BIOS Setup utility 11 Pre...

Страница 140: ...49U TR4 User s Manual Appendix E Traditional Chinese Version of Safety Warnings Additional traditional Chinese versions of warning statements are included in this appendix WARNING CAUTION WARNINGS 1 1...

Страница 141: ...Appendix E Traditional Chinese Version of Safety Warnings 141 1 2 3 4 5 1 2 3 4 1 2 3 4 1 2...

Страница 142: ...142 SuperServer 2049U TR4 User s Manual...

Отзывы: