11
Chapter 1: Introduction
Figure 1-2. Chassis Front View
Front Features
The chassis front offers access to the storage drives and a control panel for each node.
Information LED
Status
Description
Continuously on and
red
An overheat condition has occurred.
(This may be caused by cable congestion.)
Blinking red (1Hz)
Fan failure, check for an inoperative fan.
Blinking red (0.25Hz)
Power failure, check for a non-operational power
supply.
Solid blue
Local UID has been activated. Use this function
to locate the server in a rack mount environment.
Blinking blue
Remote UID is on. Use this function to identify
the server from a remote location.
Front Chassis Features
Item
Feature
Description
1
Control Panel
Described in previous section
2
Drives
Sixteen hot-swap storage drive bays
3
I/O panel
Two USB ports and one COM port
4
DVD drive bay
Bay for an optional slim DVD drive
5
5.25" drive bay
Bay for an optional peripheral drive
1
4
3
2
5