WIT Company – поставка серверов, СХД,
сетевого оборудования, лицензионного ПО
B-2
B-3
Appendix B: System Specifications
S
UPER
S
ERVER 1028R-TDW User
's Manual
Weight
Gross: 44 lbs. (19.96 kg.)
System Cooling
Five 4-cm heavy-duty counter-rotating fans
System Input Requirements
AC Input Voltage: 100-240V AC auto-range
Rated Input Current: 7.5 - 3.1A
Rated Input Frequency: 50 to 60 Hz
Power Supply
Rated Output Power: 600W (Part# PWS-605P-1H)
Rated Output Voltages: +3.3V (15A), +5V (18A), +12V (49A), -12V (0.5A), +5Vsb
(3A)
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 20% to 95% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-
3, CISPR 22 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and
Canada), CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply.
See www.dtsc.ca.gov/hazardouswaste/perchlorate”
Notes
Содержание SUPERSERVER 1028R-TDW
Страница 1: ...WIT RU WIT Company SUPERSERVER 1028R TDW USER S MANUAL 1 0a...
Страница 9: ...WIT RU WIT Company 1 6 SUPERSERVER 1028R TDW User s Manual Notes...
Страница 15: ...WIT RU WIT Company 2 10 SUPERSERVER 1028R TDW USER S MANUAL Notes...
Страница 19: ...WIT RU WIT Company 3 6 SUPERSERVER 1028R TDW USER S MANUAL Notes...
Страница 30: ...WIT RU WIT Company 4 20 SUPERSERVER 1028R TDW User s Manual Notes...
Страница 73: ...WIT RU WIT Company A 2 SUPERSERVER 1028R TDW User s Manual Notes...