Supermicro SuperServer 1027R-WTRFTP Скачать руководство пользователя страница 64

5-18

S

UPER

S

ERVER 1027R-WTRFTP User's Manual

HDD LED/UID Switch

The HDD LED connection is located 
on pins 13 and 14 of JF1. Attach a 
cable here to indicate HDD activ-
ity. See the table on the right for pin 

definitions.

Power LED 

The Power LED connection is located 
on pins 15 and 16 of JF1. Refer to the 

table on the right for pin definitions.  

NMI Button 

The non-maskable interrupt button 
header is located on pins 19 and 20 
of JF1. Refer to the table on the right 

for pin definitions.

NMI Button

Pin Definitions (JF1)

Pin#     Definition     

19

Control

20

Ground

Power LED

Pin Definitions (JF1)

Pin#     Definition     

15

3.3V

16

Control

HDD/UID Switch

Pin Definitions (JF1)

Pin#     Definition     

13

ID_UID_

SW_3.3V/3.3V SB

14

HD Active

NIC1/NIC2 LED Indicators

The NIC (Network Interface Control-
ler) LED connections for LAN port 1 
are located on pins 11 and 12 of JF1, 
and the LED connection for LAN Port 
2 are on pins 9 and 10. Attach the NIC 
LED cables here to display network 
activity. Refer to the table on the right 

for pin definitions.

Note

: The NIC LED connections for 

TLAN ports 1/2 are located on JF2 
and LEDB7.

GLAN1/2 LED

Pin Definitions (JF1)

Pin#     Definition     

9

NIC 2 Activity LED

10

NIC 2 Link LED

11

NIC 1 Activity LED

12

NIC 1 Link LED

Содержание SuperServer 1027R-WTRFTP

Страница 1: ...SUPERSERVER 1027R WTRFTP USER S MANUAL 1 0...

Страница 2: ...ny such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits f...

Страница 3: ...or to powering up the system If your server was ordered without processor and memory components this chapter will refer you to the appropriate sections of the manual for their installation Chapter 3 S...

Страница 4: ...low the procedures given in this chapter when installing removing or reconfiguring SAS or peripheral drives and when replacing system power supply modules and cooling fans Chapter 7 BIOS The BIOS chap...

Страница 5: ...v Preface Notes...

Страница 6: ...System 2 1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 1 2 4 Warnings and Precautions 2 2 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2 3 Ambient Operating Tem...

Страница 7: ...icted Area 4 9 Battery Handling 4 10 Redundant Power Supplies 4 12 Backplane Voltage 4 13 Comply with Local and National Electrical Codes 4 14 Product Disposal 4 15 Hot Swap Fan Warning 4 16 Power Cab...

Страница 8: ...em Fan Failure 6 3 Air Shroud 6 4 Hard Drive Installation 6 6 Hard Drive Backplane 6 8 DVD ROM Drive Installation 6 8 6 4 Power Supply 6 9 Power Supply Failure 6 9 Chapter 7 BIOS 7 1 Introduction 7 1...

Страница 9: ...P as listed below Five sets of 4 cm counter rotating fans FAN 0101L4 Two passive CPU heatsinks SNK P0047PS Riser Cards One RSC R1UW 2E16 One RSC R1UW E8R SAS Accessories One SAS backplane BPN SAS 113T...

Страница 10: ...12 GB of ECC RDIMM or 128 GB of ECC non ECC UDIMM DDR3 11866 600 1333 1066 800 memory Please refer to Chapter 5 for installing memory Serial ATA An on chip SATA controller is integrated into the X9DRW...

Страница 11: ...ocated on the right side of the chassis and supports one low profile max length 4 1 PCI E x8 card The RSC R1UW 2E16 is located on the left side of the chassis and supports two full height half length...

Страница 12: ...HY1 RTL8201F x16 CPU1 PE3 x16 CPU1 PE2 DDR3 DIMM H G 2 1 DDR3 DIMM 2 1 P1 P0 PE3 PE2 DMI DMI PCH C602 C602J SPI SATA SCU USB USB LPC PEG0 PEG1 4 1 PEG1_8 PCI AT25321 BMC57810S 10G SFP Chipset SAS2208...

Страница 13: ...e Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro...

Страница 14: ...1 6 SUPERSERVER 1027R WTRFTP User s Manual Notes...

Страница 15: ...e location for the rack unit that will hold the server It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are ge...

Страница 16: ...make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more si multaneously may cause the rack to become unstable Serve...

Страница 17: ...sible overloading of circuits might have on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable...

Страница 18: ...h the rack unit you are using Identifying the Sections of the Rack Rails You should have received two rack rail assemblies in the rack mounting kit Each assembly consists of two sections an inner fixe...

Страница 19: ...lize the chassis within the rack Installing the Inner Rails 1 Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes Make sure the e...

Страница 20: ...ing tab which serves two functions The first is to lock the server into place when installed and pushed fully into the rack which is its normal position Secondly these tabs also lock the server in pla...

Страница 21: ...e rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides it may be necessary to depress the locking tabs when inserting When the server has been pushed completely in...

Страница 22: ...to balance the weight between front and back If a bezel is included on your server remove it Then attach the two front brackets to each side of the chassis then the two rear brackets positioned with j...

Страница 23: ...rol Panel Buttons There are three push buttons located on the front of the chassis UID button a reset button and a power on off button UID Depressing the UID unit identifier button illuminates an LED...

Страница 24: ...may need to take Information LED This LED will be blue when the UID function has been activated When this LED flashes red it indicates a fan failure When red continuously it indicates an overheat con...

Страница 25: ...rier LEDs Green Each hard drive carrier has a green LED When illuminated this green LED indicates drive activity A connection to the SAS backplane enables this LED to blink on and off when that partic...

Страница 26: ...3 4 SUPERSERVER 1027R WTRFTP User s Manual Notes...

Страница 27: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 28: ...considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar...

Страница 29: ...l kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard proc...

Страница 30: ...ie en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de branch...

Страница 31: ...rt ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuitos o sobrecorrientes del...

Страница 32: ...eift um Systemsbestandteile anzubringen oder zu entfernen Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing t...

Страница 33: ...nentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enle...

Страница 34: ...arnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o...

Страница 35: ...stallation in Bereichen mit beschr nktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m gli...

Страница 36: ...ame or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een...

Страница 37: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 38: ...para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour suppri...

Страница 39: ...ero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circulent sur le fond de panier Prendre des pr cautions lors de la maintenanc...

Страница 40: ...lectrical codes Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Bac...

Страница 41: ...ional laws and regulations Attention L quipement doit tre install conform ment aux normes lectriques nationales et locales Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lok...

Страница 42: ...seguir todas las leyes y reglamentos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vo...

Страница 43: ...dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilat...

Страница 44: ...Adapter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r alle an...

Страница 45: ...utres appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bi...

Страница 46: ...4 20 SUPERSERVER 1027R WTRFTP User s Manual Notes...

Страница 47: ...uit boards it is important to handle them very carefully see Chapter 4 Also note that the size and weight of the serverboard can cause it to bend if handled improperly which may result in damage To pr...

Страница 48: ...sink only Make sure to install the serverboard into the chassis before you install the CPU heatsinks When receiving a serverboard without a processor pre installed make sure that the plastic CPU socke...

Страница 49: ...remove the WARNING plastic cap from the socket 5 Use your thumb and index finger to hold the CPU by its edges Align the CPU keys which are semi circle cutouts against the socket keys 6 Once they are a...

Страница 50: ...d plate again and double check that the CPU is aligned properly 7 With the CPU in the socket in spect the four corners of the CPU to make sure that they are flush with the socket 8 Close the load plat...

Страница 51: ...doing this 4 Once the heatsink is loosened remove it from the CPU 5 Clean the surface of the CPU and the heatsink to get rid of the old thermal grease Reapply the proper amount of thermal grease befo...

Страница 52: ...ply connector designated JPW1 for connection to the ATX power supply Connect the appropriate connec tor from the power supply to JPW1 to supply power to the serverboard See the Connector Definitions s...

Страница 53: ...10 11 12 Rear I O Ports 1 Keyboard 7 VGA Port 2 PS 2 Mouse 8 1 Gb LAN1 Port 3 USB0 9 1 Gb LAN2 Port 4 USB1 10 10 Gb SFP LAN3 Port 5 Dedicated IPMI LAN 11 10 Gb SFP LAN4 Port 6 COM1 12 UID Button Powe...

Страница 54: ...le to prevent inserting the DIMM module incorrectly see Figure 5 5 3 Gently press down on the DIMM module until it snaps into place in the slot Repeat for all modules Memory Support The X9DRW iTPF sup...

Страница 55: ...ble For memory to work properly follow the instructions below 1 CPU 2 DIMMs CPU1 P1 DIMMA1 P1 DIMMB1 1 CPU 4 DIMMs CPU1 P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 1 CPU 5 8 DIMMs CPU1 P1 DIMMA1 P1 DIMMB1...

Страница 56: ...ur website at http www supermicro com support resources mem cfm Populating RDIMM ECC Memory Modules Intel E5 2600 v2 Series Processor RDIMM Memory Support Ranks Per DIMM Data Width Memory Capacity Per...

Страница 57: ...cfm Populating RDIMM ECC Memory Modules Intel E5 2600 Series Processor RDIMM Memory Support Ranks Per DIMM Data Width Memory Capacity Per DIMM See the Note Below Speed MT s and Voltage Validated by Sl...

Страница 58: ...RDIMM Memory Support Ranks Per DIMM Data Width Memory Capacity Per DIMM See the Note Below Speed MT s and Voltage Validated by Slot per Channel SPC and DIMM Per Channel DPC 2 Slots Per Channel 3 Slots...

Страница 59: ...tion Before installing a PCI add on card make sure you power off the system first Begin by removing the top chassis cover Two riser cards should be pre installed into the system Remove the screws that...

Страница 60: ...AS4 7 P2 DIMMF1 P2 DIMMF2 SXB1B SXB1A USB4 5 USB2 3 COM2 P1 DIMMD1 BATTERY P1 DIMMD2 P1 DIMMC1 P1 DIMMC2 P2 DIMME1 UID P2 DIMME2 TLAN1 LAN2 LAN1 P1 DIMMB2 P1 DIMMB1 P2 DIMMH2 P2 DIMMH1 P1 DIMMA2 IPMI_...

Страница 61: ...PMB1 4 pin External BMC I2 C Header for an IPMI card JL1 Chassis Intrusion Header JOH1 Overheat Fan Fail LED JPI2 C1 Power Supply SMBbus I2 C Header JPW1 ATX 24 Pin Power Connector JPW2 JPW3 12V 8 Pin...

Страница 62: ...tional USB 6 Front Panel Type A USB 6 Port UID Switch UID Unit Identifier Switch LED Description Color State Status LE1 Standby PWR LED Green On Power On LE2 UID LED Blue Unit Identified LEDB7 Activit...

Страница 63: ...n main power supply connector JPW1 and two 8 pin power connectors JPW2 JPW3 are pro vided on the serverboard and must be connected to your power supply These power connectors meet the SSI EPS 12V spec...

Страница 64: ...ons JF1 Pin Definition 19 Control 20 Ground Power LED Pin Definitions JF1 Pin Definition 15 3 3V 16 Control HDD UID Switch Pin Definitions JF1 Pin Definition 13 ID_UID_ SW_3 3V 3 3V SB 14 HD Active NI...

Страница 65: ...Definitions JF1 Pin Definition 5 3 3V 6 PWR Supply Fail Power Button Pin Definitions JF1 Pin Definition 1 Signal 2 Ground Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1...

Страница 66: ...ion Unit Identifier Switch A Unit Identifier UID Switch and two LED Indicators are located on the serverboard The UID Switch is located next to the 10G LAN 2 port on the backplane The Rear UID LED LE2...

Страница 67: ...Fan Header Pin Definitions Pin Definition 1 Ground 2 12V 3 Tachometer 4 PWR Modulation Fan Headers This serverboard has six system CPU fan headers Fan 1 Fan 5 Fan A All are 4 pin fans headers and back...

Страница 68: ...PWR Fail 4 Ground 5 3 3V IPMB A System Management Bus header for IPMI 2 0 is located at JIPMB1 Connect the appropriate cable here to use the IPMB I2 C connection on your system IPMB Header Pin Defini...

Страница 69: ...bit small form factor pluggable SFP transceivers optimized for onboard telecommunication and data communications In addition to LAN TLAN ports a dedicated IPMI LAN port located above the USB 0 1 ports...

Страница 70: ...3V 10 LAD1 11 LAD0 12 GND 13 SMB_CLK4 14 SMB_DAT4 15 3V_DUAL 16 SERIRQ 17 GND 18 CLKRUN X 19 LPCPD 20 LDRQ X Front Panel LEDs for TLAN1 TLAN2 The Front Panel LED indicator for TLAN port 1 is located o...

Страница 71: ...ill also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS 1 First power down the system and unplug the power...

Страница 72: ...h Dog Timer Watch Dog Jumper Settings Jumper Setting Definition Pins 1 2 Reset Pins 2 3 NMI Open Disabled LAN Enable Disable Jumper Settings Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disable...

Страница 73: ...anufacture Mode ME Manufacture Mode Jumper JPME2 allows the user to flash the system firmware from a host server to modify system settings Close this jumper to bypass SPI flash security and force ME i...

Страница 74: ...ar the I O ports This LED is used in conjunction with the rear UID switch to provide easy identification of a system that might be in need of service UID LED Color State OS Status Blue On Windows Unit...

Страница 75: ...Serial ATA Ports There are two SATA 3 0 ports I SATA0 1 and eight SATA 2 0 ports I SATA 2 5 S SATA 0 3 provided on the serverboard In addition I SATA5 also functions as a wireless SATA DOM that can be...

Страница 76: ...ged with your serverboard Driver Tool Installation Display Screen Note Click the icons showing a hand writing on paper to view the readme files for each item Click the computer icons to the right of t...

Страница 77: ...ment and operations of your system SuperDoctor III displays crucial system information such as CPU temperature system voltages and fan status See the Figure below for a display of the SuperDoctor III...

Страница 78: ...I Interface Display Screen Remote Control Note The SuperDoctor III program and User s Manual can be downloaded from the Supermicro web site at http www supermicro com products accessories software Sup...

Страница 79: ...t damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a gr...

Страница 80: ...e red wire plugs into pin 1 on both connectors Pull all excess cabling out of the airflow path The control panel LEDs inform you of system status See Chapter 3 System In terface for details on the LED...

Страница 81: ...the fan tray 3 Place the new fan into the vacant space in the housing while making sure the arrows on the top of the fan indicating air direction point in the same direc tion as the arrows on the othe...

Страница 82: ...n efficiency The SC119 chassis air shroud does not require screws to set up Air Shroud Installation 1 Disconnect the chassis from any power souce 2 Align the notch on the air shroud with the screw on...

Страница 83: ...rive you will need to gain access to the inside of the server by removing the top cover of the chassis Proceed to the DVD ROM Drive Installation section later in this chapter for instructions Note Onl...

Страница 84: ...drives installed must remain in the chassis Removing Hard Drive Carrier from the Chassis 1 Press the release button on the drive carrier This extends the drive carrier handle 2 Use the handle to pull...

Страница 85: ...the carrier 3 Align the drive in the carrier so that the screw holes of both line up Note that there are holes in the carrier marked SAS to aid in correct installation 4 Secure the drive to the carri...

Страница 86: ...sary remove the server from the rack 2 Remove the chassis cover 3 Unplug the drive s power and data cables from the serverboard and or back plane 4 Unlock the mini bezel lock scew and remove the mini...

Страница 87: ...until the failed unit has been replaced Replace ment units can be ordered directly from Supermicro The power supply units have a hot swap capability meaning you can replace the failed unit without po...

Страница 88: ...6 10 SUPERSERVER 1027R WTRFTP User s Manual Figure 6 5 Removing Replacing the Power Supply...

Страница 89: ...he options that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved...

Страница 90: ...n access the other setup screens An AMI BIOS identification string is displayed at the left bottom corner of the screen below the copyright message Warning Do not upgrade the BIOS unless your system h...

Страница 91: ...The date must be entered in Day MM DD YY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 Supermicro X9DRW 7 iTPF Version...

Страница 92: ...POST messages The op tions are Enabled and Disabled AddOn ROM Display Mode Use this item to set the display mode for the Option ROM Select Keep Current to use the current AddOn ROM Display setting Sel...

Страница 93: ...than five minutes The options are Enabled and Disabled Power Button Function If this feature is set to Instant Off the system will power off immediately as soon as the user presses the power button If...

Страница 94: ...n Socket 1 or Socket 2 supports 64 bit technology Clock Spread Spectrum Select Enable to enable Clock Spectrum support which will allow the BIOS to moni tor and attempt to reduce the level of Electrom...

Страница 95: ...o use the Intel Advanced Encryption Standard AES New Instruc tions NI to ensure data security The options are Enabled and Disabled MLC Streamer Prefetcher Available when supported by the CPU If set to...

Страница 96: ...sable power saving settings The options are Disabled Energy Efficient and Custom If the option is set to Custom the following items will display EIST Available when Power Technology is set to Custom E...

Страница 97: ...um system performance with maximum cooling or maximum energy efficiency with maxi mum power saving The fan speeds are controlled by the firmware management via IPMI 2 0 The options are Performance Bal...

Страница 98: ...feature offers fully protected I O resource sharing across Intel platforms providing greater reliability security and availability in networking and data sharing The options are Enabled and Disabled...

Страница 99: ...tions are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto IIO 2 PCIe Port Bifurcation Control This submenu configures the following IO PCIe Port Bifurcation Control settings for IIO 2 PCIe ports to determine...

Страница 100: ...connections The options are Slow and Fast QPI Link Frequency Select Use this feature to select the desired QPI frequency The options are Auto 6 4 GT s 7 2 GT s and 8 0 GT s DIMM Configuration This sec...

Страница 101: ...y saving The options are Performance and Energy Saving DDR Speed Use this feature to force a DDR3 memory module to run at a frequency other than what is specified in the specification The options are...

Страница 102: ...rottling improves reliability and reduces power consumption in the proces sor via automatic voltage control during processor idle states The options are Disabled and CLTT Closed Loop Thermal Throttlin...

Страница 103: ...e EHCI hand off When enabled EHCI ownership change will be claimed by the EHCI driver The options are Disabled and Enabled SATA Configuration When this submenu is selected the AMI BIOS automatically d...

Страница 104: ...Spin up support to prevent excessive power consumption caused by multiple HDDs spinning up simultaneously The options are Enabled and Disabled RAID Mode The following items are displayed when RAID Mo...

Страница 105: ...automatically set the maximum payload value for a PCI E device to enhance system performance The options are Auto 128 Bytes and 256 Bytes Maximum Read Request Select Auto to allow the system BIOS to...

Страница 106: ...sabled Load Onboard SAS Option ROM Select Enabled to use the onboard SAS Option ROM to boot the computer using a SAS device The options are Enabled and Disabled VGA Priority This feature allows the us...

Страница 107: ...is feature to select the desired mode for a serial port specified The options are Normal and High Speed Serial Port 2 Configuration SOL Serial Port Select Enabled to enable serial port 2 The options a...

Страница 108: ...00 to use the ASCII Character set Select VT100 to add color and function key support Select ANSI to use the Extended ASCII Char acter Set Select VT UTF8 to use UTF8 encoding to map Unicode characters...

Страница 109: ...support for ANSI VT100 terminals The options are Enabled and Disabled Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server The optio...

Страница 110: ...ation type for Con sole Redirection Select VT100 to use the ASCII character set Select VT100 to add color and function key support Select ANSI to use the extended ASCII character set Select VT UTF8 to...

Страница 111: ...nabled and Disabled High Precision Event Timer Select Enabled to activate the High Precision Event Timer HPET that produces periodic interrupts at a much higher frequency than a Real time Clock RTC do...

Страница 112: ...ve Status This item displays the status of TPM Support to indicate if TPM is currently ac tive or deactivated TPM Owner Status This item displays the status of TPM Ownership Intel TXT LT SX Configurat...

Страница 113: ...tate Trusted Platform state ME Subsystem This feature displays the following ME Subsystem Configuration settings ME BIOS Interface Version ME Version iSCSI Configuration This item displays iSCSI confi...

Страница 114: ...AutoNeg 10Mbps Half 10Mbps Full 100Mbps Half and 100Mbps full Wake on LAN Select enabled to wake the system with a magic packet The options are En abled and Disabled Blink LEDs This feature allows the...

Страница 115: ...em Management BIOS Event Logging during system boot The options are Enabled and Disabled Runtime Error Logging Support Select Enabled to support Runtime Error Logging The options are Enabled and Disab...

Страница 116: ...ons are Do Nothing and Erase Immediately SMBIOS Event Log Standard Settings Log System Boot Event Select Enabled to log system boot events The options are Disabled and Enabled MECI Multiple Event Coun...

Страница 117: ...stalled in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings Erase SEL...

Страница 118: ...effect when the system is rebooted The options are No and Yes Configuration Address Source This feature allows the user to select the source of the IP address for this computer If Static is selected y...

Страница 119: ...ce etc Use these items to specify the sequence of boot device priority Delete Boot Option This feature allows the user to select a boot device to delete from the boot priority list Delete Boot Option...

Страница 120: ...n a password entry is required Select Setup to require the password only when entering setup Select Always to require the pass word when entering setup and on each boot The options are Setup and Alway...

Страница 121: ...Reset When you have completed the system configuration changes select this option to save the changes and reboot the computer so that the new system configuration settings can take effect Select Save...

Страница 122: ...faults Select this feature and press Enter to save the current settings as the user s defaults When the dialog box appears asking you if you want to save values as user s defaults select Yes to save t...

Страница 123: ...curs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond...

Страница 124: ...A 2 SUPERSERVER 1027R WTRFTP User s Manual Notes...

Страница 125: ...or 128 GB of ECC non ECC UDIMM DDR3 11866 600 1333 1066 800 memory See the memory section in Chapter 5 for details SATA Intel on chip SATA controller for 10 port SATA two SATA 3 0 ports and eight SATA...

Страница 126: ...40 to 140 F Operating Relative Humidity 8 to 90 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022 Class A EN 6...

Страница 127: ...B 3 Appendix B System Specifications Notes...

Страница 128: ...erform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such...

Отзывы: