5-18
S
UPER
S
ERVER 1015B-3 User's Manual
Redundant Power Supply Fail
Connect a cable from your power
supply to the header at J3P to pro-
vide warning of a redundant power
supply failure. This warning signal is
passed through the PWR_LED pin to
indicate a power failure on the chas-
sis. See the table on the right for pin
defi nitions.
Note:
This feature is only available when using
Supermicro redundant power supplies.
PWR Supply Fail Alarm
Pin Defi nitions (J3P)
Pin# Defi nition
1
PWR 1: Fail
2
PWR 2: Fail
3
PWR 3: Fail
4
Signal: Alarm Reset
Alarm Reset
If three power supply modules are
installed, the system can notify you
when any of the three fails. Connect
JAR to a micro-switch to enable you
to turn off the alarm that is activated
when a power module fails. See the
table on the right for pin defi nitions.
Alarm Reset
Pin Defi nitions (JAR)
Pin Setting Defi nition
Pin 1
Ground
Pin 2
Alarm Reset
I-Button
The I- Button, located above the
LSI chip on the motherboard, is a
computer chip enclosed in a durable
stainless container to enable RAID 5
under Software RAID mode. See the
table on the right for pin defi nitions.
I-Button
Pin Defi nitions
Pin# Defi nition
1
Ground
2
GPIO1
3
Ground
Содержание SUPERSERVER 1015B-3
Страница 1: ...SUPER USER S MANUAL Revision 1 0 SUPERSERVER 1015B 3...
Страница 5: ...v Preface Notes...
Страница 10: ...Notes SUPERSERVER 1015B 3 User s Manual x...
Страница 16: ...1 6 SUPERSERVER 1015B 3 User s Manual Notes...
Страница 23: ...Chapter 2 Server Installation 2 7 Figure 2 4 Installing the Outer Rails to the Rack 2 3 3...
Страница 71: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 6 Removing Replacing the Power Supply Retention screws...
Страница 72: ...6 10 SUPERSERVER 1015B 3 Manual Notes...
Страница 94: ...A 2 SUPERSERVER 1015B 3 User s Manual Notes...