SC936 Chassis Manual
4-8
Figure 4-7: System Fan
Release Tab
The air shroud includes perforations on the bottom. These perforations can be
5.
removed if motherboard components interfere with the air shroud placement.
Do not remove more perforations than necessary.
Install the rear fans by sliding each fan into the fan housing on the chassis.
6.
Checking the Server's Air Flow
Make sure there are no objects to obstruct airflow in and out of the server. In
1.
addition, if you are using a front bezel, make sure the bezel's filter is replaced
periodically.
Do not operate the server without drive carriers in the drive bays. Use only
2.
recommended server parts.
Make sure no wires or foreign objects obstruct air flow through the chassis.
3.
Pull all excess cabling out of the airflow path or use shorter cables.
The control panel LEDs inform you of system status. See “Chapter 3: System
4.
Interface” for details on the LEDs and the control panel buttons.
In most cases, the chassis power supply and fans are pre-installed. If you need to
install fans continue to the Systems Fan section of this chapter. If the chassis will be
installed into a rack, continue to the next chapter for rack installation instructions.
4-6 System Fans
Five heavy-duty fans provide cooling for the chassis. These fans circulate air through
the chassis as a means of lowering the chassis internal temperature.
Содержание Supero SC936 Series
Страница 18: ...SC936 Chassis Manual 3 4 Notes ...
Страница 30: ...SC936 Chassis Manual 4 12 Notes ...
Страница 40: ...SC936 Chassis Manual 5 10 Notes ...
Страница 46: ...SC936 Chassis Manual B 2 Notes ...