Chapter 2: Server Installation
2-5
2-4
S
UPER
S
TORAGE
S
YSTEM 6037R-E1R16N User's Manual
Installing the Chassis Rails
Position one of the chassis rail sections you just removed along the side of the
6037R-E1R16N. Note that the two chassis rails are left/right specific. Locate the
numerous rail tabs on each side of the chassis and the corresponding holes on
each of the chassis rails. Note that the holes are elongated with one end of the
hole larger than the other. Align the larger end of each hole with its corresponding
tab. With all holes and tabs aligned, position the rail onto the side of the chassis
(see Figure 2-2). Once a rail is positioned on the chassis, pull it forward until the
rail tabs lock in the small ends of the corresponding holes. Then secure the rail to
the chassis with the screws included in the harware kit. Repeat the above steps to
install the other rail on the chassis.
Locking Tabs:
As mentioned, both chassis rails have locking tabs, which serve to
lock the server into place when installed and pushed fully into the rack (its normal
position).
Figure 2-2. Installing Chassis Rails
2-5 Installing the System into a Rack
This section provides information on installing the SuperServer 6037R-E1R16N
into a rack unit. If the 6037R-E1R16N has already been mounted into a rack, you
can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the
market, which may mean the assembly procedure will differ slightly. The following
is a guideline for installing the 6037R-E1R16N into a rack with the rack rails pro-
vided. You should also refer to the installation instructions that came with the rack
unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies with the SuperServer 6037R-
E1R16N. Each of these assemblies consist of two sections: an inner chassis rail
that secures to the chassis (A) and an outer rack rail that secures directly to the
rack itself (B). All screws and hardware mentioned in the installation steps should
be included in the hardware kit.
To remove the chassis rail (A), pull it out as far as possible - you should hear a
"click" sound as a locking tab emerges from inside the rail assembly and locks the
inner rail. Then depress the locking tab to pull the inner rail completely out. Do this
for both the left and right side rack rail assemblies.
Figure 2-1. Identifying the Sections of the Rack Rails
A
B
Locking Tab
Warning:
do not pick up the server with the front handles. They are de-
signed to pull the system from a rack only.
Содержание Supero 6037R-E1R16N
Страница 1: ... SUPER STORAGE SYSTEM 6037R E1R16N SUPER USER S MANUAL 1 0c ...
Страница 14: ...2 8 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Страница 17: ...3 4 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Страница 28: ...4 20 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Страница 46: ...5 34 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Страница 53: ...6 12 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Страница 70: ...7 32 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...
Страница 72: ...A 2 SUPERSTORAGESYSTEM 6037R E1R16N User s Manual Notes ...