Supermicro SSE-F3548S/SSE-F3548SR Configuration User’s Guide
33
The example below shows the commands used to configure the interface MTU.
SMIS# configure terminal
SMIS(config)# interface fx 0/22
SMIS(config-if)# mtu 9000
SMIS(config-if)# end
SMIS
# show interface fx 0/22
Fx0/22 up, line protocol is down (not connect)
Bridge Port Type: Customer Bridge Port
Hardware Address is 00:25:90:80:81:98
MTU 1500 bytes, Full duplex, 10 Gbps, No-Negotiation
HOL Block Prevention enabled.
Input flow-control is off, output flow-control is off
Link Up/Down Trap is enabled
Reception Counters
Octets: 0
Unicast Packets: 0
Unicast Packets Rate: 0/Sec
Broadcast Packets: 0
Broadcast Packets Rate: 0/Sec
Multicast Packets: 0
Multicast Packets Rate: 0/Sec
Overall Packets Rate: 0/Sec
Pause Frames: 0
Undersize Frames: 0
Oversize Frames: 0