Supermicro SSE-F3548S/SSE-F3548SR Configuration User’s Guide
209
SMIS# configure terminal
SMIS(config)# no ip igmp snooping
SMIS(config)# vlan 1,10,20
SMIS(config-vlan)# no ip igmp snooping
SMIS(config-vlan)# end
7.13
IGMP Snooping Configuration Example
Configure the following requirements on Switch A as shown below in Figure IGS-4.
1.
Enable IGMP snooping.
2.
There is no multicast router for group 225.0.0.1 so configure the switch as a querier for this
group.
3.
Use IGMP v2 for group 225.0.0.1 and also enable fast leave since hosts are directly connected to
the switch.
4.
Disable the proxy reporting.
5.
Enable the switch to send general IGMP queries when spanning tree topology changes.
Figure IGS-4IGMP Snooping Configuration Example
SMIS# configure terminal
# Create all the required VLANs first
SMIS(config)# vlan 10,20
SMIS(config-vlan)# exit
# Add member ports to VLAN 10
225.0.0.1
Source
VLAN 20
Switch B
VLAN 20
Switch A
Trunk – po 1
Native VLAN 10
VLAN 10
Processin
gEx 0/1
Fx 0/20
Fx 0/40
Fx
0/
1
Fx
0/
10
Cx 0/3
Cx 0/4
225.0.0.1 Receiver Hosts
225.0.0.10
Receiver Hosts
225.0.0.10
Source